Superheated emulsion in neutron spectrometry

被引:0
|
作者
Das, M [1 ]
Sawamura, S [1 ]
Sawamura, T [1 ]
机构
[1] Hokkaido Univ, Grad Sch Engn, Dept Quantum Energy Engn, Kita Ku, Sapporo, Hokkaido 0608628, Japan
关键词
metastability; neutron; sensitivity; spectrum; LINAC;
D O I
10.1016/j.apradiso.2005.05.029
中图分类号
O61 [无机化学];
学科分类号
070301 ; 081704 ;
摘要
The application of superheated emulsion as a neutron spectrometer is described by varying the operating temperature and the ambient pressure of the emulsion. For the calibration of the detector, a relationship was established between the degree of metastability (ss) of superheated emulsion and the threshold neutron energy. The sensitivity and the integral response of the emulsion was calculated and compared with the experimental results. (c) 2005 Elsevier Ltd. All rights reserved.
引用
收藏
页码:583 / 587
页数:5
相关论文
共 50 条
  • [1] Application of superheated emulsion in neutron spectrometry at 45 MeV electron linac
    Das, M
    Sawamura, T
    Kitaichi, M
    Sawamura, S
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2004, 517 (1-3): : 34 - 41
  • [2] ACTIVE NEUTRON SPECTROMETRY WITH SUPERHEATED DROP (BUBBLE) DETECTORS
    DERRICO, F
    ALBERTS, WG
    CURZIO, G
    GULDBAKKE, S
    KLUGE, H
    MATZKE, M
    RADIATION PROTECTION DOSIMETRY, 1995, 61 (1-3) : 159 - 162
  • [3] Superheated emulsions in neutron spectrometry by varying ambient pressure
    Das, M
    Sawamura, T
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2005, 536 (1-2): : 123 - 130
  • [4] Estimation of nucleation parameter for neutron-induced nucleation in superheated emulsion
    Das, M
    Sawamura, T
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2004, 531 (03): : 577 - 584
  • [5] High-energy neutron detection and spectrometry with superheated emulsions
    d'Errico, F
    Prokofiev, A
    Sannikov, A
    Schuhmacher, H
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2003, 505 (1-2): : 50 - 53
  • [6] Neutron spectrometry in mixed fields: Superheated drop (bubble) detectors
    d'Errico, F
    Matzke, M
    RADIATION PROTECTION DOSIMETRY, 2003, 107 (1-3) : 111 - 124
  • [7] NUCLEAR-EMULSION NEUTRON SPECTROMETRY IN THE FFTF
    GOLD, R
    ROBERTS, JH
    TRANSACTIONS OF THE AMERICAN NUCLEAR SOCIETY, 1981, 39 : 896 - 896
  • [8] Gamma photon techniques for detection of nucleation in superheated emulsion detectors for neutron dosimetry
    Priyada, P.
    Ramar, R.
    Krishnan, H.
    Viswanathan, S.
    Shivaramu
    RADIATION PROTECTION DOSIMETRY, 2014, 158 (01) : 100 - 106
  • [9] The performance evaluation of gamma- and neutron-sensitive superheated emulsion (bubble) detectors
    Vaijapurkar, S. G.
    Senwar, Kana Ram
    Hooda, J. S.
    Parihar, A.
    RADIATION PROTECTION DOSIMETRY, 2008, 130 (03) : 285 - 290
  • [10] Superheated drop as a neutron spectrometer
    Das, M
    Chatterjee, BK
    Roy, B
    Roy, SC
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2000, 452 (1-2): : 273 - 279