Inert coupling of IRDye800CW to monoclonal antibodies for clinical optical imaging of tumor targets

被引:72
|
作者
Cohen, Ruth [1 ]
Stammes, Marieke A. [1 ]
de Roos, Inge H. C. [1 ]
Stigter-van Walsum, Marijke [1 ]
Visser, Gerard W. M. [2 ]
van Dongen, Guus A. M. S. [1 ]
机构
[1] Vrije Univ Amsterdam, Med Ctr, Dept Otolaryngol Head & Neck Surg, NL-1007 MB Amsterdam, Netherlands
[2] Vrije Univ Amsterdam, Med Ctr, Dept Nucl Med & PET Res, NL-1007 MB Amsterdam, Netherlands
来源
EJNMMI RESEARCH | 2011年 / 1卷
关键词
zirconium-89; monoclonal antibodies; IRDye800CW; cetuximab; bevacizumab;
D O I
10.1186/2191-219X-1-31
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background: Photoimmunodetection, in which monoclonal antibodies [mAbs] are labeled with fluorescent dyes, might have clinical potential for early detection and characterization of cancer. For this purpose, the dye should be coupled in an inert way to mAb. In this study, different equivalents of IRDye800CW, a near-infrared fluorescent dye, were coupled to Zr-89-labeled cetuximab and bevacizumab, and conjugates were evaluated in biodistribution studies. Radiolabeled mAbs were used to allow accurate quantification for assessment of the number of dye groups that can be coupled to mAbs without affecting their biological properties. Methods: Zr-89-cetuximab and Zr-89-bevacizumab, containing 0.5 Zr-89-desferal group per mAb molecule, were incubated with 1 to 10 eq IRDye800CW at pH 8.5 for 2 h at 35 degrees C, and Zr-89-mAb-IRDye800CW conjugates were purified by a PD10 column using 0.9% NaCl as eluent. HPLC analysis at 780 nm was used to assess conjugation efficiency. In vitro stability measurements were performed in storage buffer (0.9% NaCl or PBS) at 4 degrees C and 37 degrees C and human serum at 37 degrees C. 89Zr-mAb-IRDye800CW conjugates and Zr-89-mAb conjugates (as reference) were administered to nude mice bearing A431 (cetuximab) or FaDu (bevacizumab) xenografts, and biodistribution was assessed at 24 to 72 h after injection. Results: Conjugation efficiency of IRDye800CW to Zr-89-mAbs was approximately 50%; on an average, 0.5 to 5 eq IRDye800CW was conjugated. All conjugates showed optimal immunoreactivity and were > 95% stable in storage buffer at 4 degrees C and 37 degrees C and human serum at 37 degrees C for at least 96 h. In biodistribution studies with Zr-89-cetuximabIRDye800CW, enhanced blood clearance with concomitant decreased tumor uptake and increased liver uptake was observed at 24 to 72 h post-injection when 2 or more eq of dye had been coupled to mAb. No significant alteration of biodistribution was observed 24 to 48 h after injection when 1 eq of dye had been coupled. (89)Zrbevacizumab-IRDye800CW showed a similar tendency, with an impaired biodistribution when 2 eq of dye had been coupled to mAb. Conclusion: Usage of Zr-89-mAbs allows accurate quantification of the biodistribution of mAbs labeled with different equivalents of IRDye800CW. Alteration of biodistribution was observed when more than 1 eq of IRDye800CW was coupled to mAbs.
引用
收藏
页码:1 / 13
页数:13
相关论文
共 31 条
  • [1] Inert coupling of IRDye800CW to monoclonal antibodies for clinical optical imaging of tumor targets
    Ruth Cohen
    Marieke A Stammes
    Inge HC de Roos
    Marijke Stigter-van Walsum
    Gerard WM Visser
    Guus AMS van Dongen
    EJNMMI Research, 1
  • [2] Inert coupling of IRDye800CW to monoclonal antibodies for optical imaging of critical tumor targets
    Ruth, Cohen
    Marieke, Stammes
    Marijke, Stigter-van Walsum
    Gerard, Visser M. W.
    van Dongen, Guus A. M. S.
    JOURNAL OF LABELLED COMPOUNDS & RADIOPHARMACEUTICALS, 2011, 54 : S148 - S148
  • [3] Inert coupling of IRDye800CW and zirconium-89 to monoclonal antibodies for single- or dual-mode fluorescence and PET imaging
    Cohen, Ruth
    Vugts, Danielle J.
    Stigter-van Walsum, Marijke
    Visser, Gerard W. M.
    van Dongen, Guus A. M. S.
    NATURE PROTOCOLS, 2013, 8 (05) : 1010 - 1018
  • [4] Inert coupling of IRDye800CW and zirconium-89 to monoclonal antibodies for single- or dual-mode fluorescence and PET imaging
    Ruth Cohen
    Danielle J Vugts
    Marijke Stigter-van Walsum
    Gerard W M Visser
    Guus A M S van Dongen
    Nature Protocols, 2013, 8 : 1010 - 1018
  • [5] Characterizing fluorescent imaging properties of antibodies conjugated to IRDye800CW for use in imaging of head and neck cancer
    Foster, Robert C.
    Krell, Asher M.
    Chung, Thomas K.
    Warram, Jason M.
    Zinn, Kurt R.
    Rosenthal, Eben L.
    PHOTONIC THERAPEUTICS AND DIAGNOSTICS X, 2014, 8926
  • [6] In vivo fluorescent optical imaging of cytotoxic T lymphocyte migration using IRDye800CW near-infrared dye
    Foster, Aaron E.
    Kwon, Sunkuk
    Ke, Shi
    Lu, An
    Eldin, Karen
    Sevick-Muraca, Eva
    Rooney, Cliona M.
    APPLIED OPTICS, 2008, 47 (31) : 5944 - 5952
  • [7] Estimation of detection limits of a clinical fluorescence optical mammography system for the near-infrared fluorophore IRDye800CW: phantom experiments
    Adams, Arthur
    Mourik, Jurgen E. M.
    van der Voort, Marjolein
    Pearlman, Paul C.
    Nielsen, Tim
    Mali, Willem P. Th M.
    Elias, Sjoerd G.
    JOURNAL OF BIOMEDICAL OPTICS, 2012, 17 (07)
  • [8] Dual modality imaging of PSMA-expressing prostate cancer with a new radiolabeled anti-PSMA monoclonal antibody conjugated with IRDye800CW
    Lutje, S.
    Rijpkema, M.
    Franssen, G. M.
    Helfrich, W.
    Fracasso, G.
    Oyen, W. J.
    Colombatti, M.
    Boerman, O. C.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2013, 40 : S155 - S155
  • [9] Identification of Optimal Tissue-Marking Dye Color for Pathological Evaluation in Fluorescence Imaging Using IRDye800CW
    Takahito Kondo
    Naoki Nishio
    Jason S. Park
    Lucas D. Mani
    Abdullah Naveed
    Hidenori Tanaka
    James S. Lewis
    Eben L. Rosenthal
    Marisa E. Hom
    Molecular Imaging and Biology, 2024, 26 : 162 - 172
  • [10] Identification of Optimal Tissue-Marking Dye Color for Pathological Evaluation in Fluorescence Imaging Using IRDye800CW
    Kondo, Takahito
    Nishio, Naoki
    Park, Jason S.
    Mani, Lucas D.
    Naveed, Abdullah
    Tanaka, Hidenori
    Lewis, James S., Jr.
    Rosenthal, Eben L.
    Hom, Marisa E.
    MOLECULAR IMAGING AND BIOLOGY, 2024, 26 (01) : 162 - 172