Influence of iterative reconstruction and dose levels on metallic artifact reduction: A phantom study within four CT systems

被引:12
|
作者
Greffier, J. [1 ]
Larbi, A. [1 ]
Frandon, J. [1 ]
Daviau, P. A. [1 ]
Beregi, J. P. [1 ]
Pereira, F. [1 ]
机构
[1] Univ Montpellier, CHU Nimes, Dept Radiol, Med Imaging Grp Nimes,EA 2415, F-30029 Nimes, France
关键词
Metallic artifact reduction (MAR); Computed tomography (CT); Image quality; Iterative reconstruction; COMPUTED-TOMOGRAPHY;
D O I
10.1016/j.diii.2018.12.007
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To compare metallic artifact reduction (MAR) algorithms proposed by four vendors according to the delivered dose and iterative level using a phantom study. Methods: Four CT systems (Revolution GSI (R), Ingenuity Elite (R), Somatom Edge (R), and Aquilion Prime (R)) equipped with MAR algorithms (Smart MAR (R), O-MAR (R), iMAR (R), and SEMAR (R)) were compared. Acquisitions were performed with CIRS model 062M Phantom containing a titanium rod core insert using 120 kV and two dose levels (3 and 7 mGy). Images were reconstructed with and without MAR algorithms using standard "soft tissue'' kernel for filtered back projection (FBP) and intermediary iterative level. Artifact propagation was assessed by counting the number of pixels containing a HU outside a defined threshold interval (> 100HU and < -80 HU). Artifact correction was evaluated by computing the differences between images with and without MAR. Results: Accuracy of NCT values increased significantly using MAR algorithms, IR, and high dose levels (P < 0.001). Image noise reduced -31 +/- 15 (SD) % (range: -50%;-14%) with Smart-MAR (R), -28 +/- 3 (SD) % (range -31%; -25%) with O-MAR (R), -32 +/- 7 (SD) % (range: -40%; -24%) with iMARCN (R), -52 +/- 8 (SD) % (range: -60%; -42%) with iMARTH (R) and -29 +/- 6 (SD) % (range: -37%; -23%) with SEMAR (R). The number of pixels outside the threshold interval was also reduced using MAR algorithms. Each MAR algorithm corrected in distinct patterns, with satisfactory artifact correction for all MAR algorithms. Conclusion: This study demonstrates that artifact correction using MAR algorithms differs according to the main manufacturers, although corrections are satisfactory for all systems. Corrections also improved by using IR and increasing the dose level. (c) 2019 Societe francaise de radiologie. Published by Elsevier Masson SAS. All rights reserved.
引用
收藏
页码:269 / 277
页数:9
相关论文
共 50 条
  • [1] Influence of dose reduction and iterative reconstruction on CT calcium scores: a multi-manufacturer dynamic phantom study
    van der Werf, N. R.
    Willemink, M. J.
    Willems, T. P.
    Greuter, M. J. W.
    Leiner, T.
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2017, 33 (06): : 899 - 914
  • [2] Influence of dose reduction and iterative reconstruction on CT calcium scores: a multi-manufacturer dynamic phantom study
    N. R. van der Werf
    M. J. Willemink
    T. P. Willems
    M. J. W. Greuter
    T. Leiner
    The International Journal of Cardiovascular Imaging, 2017, 33 : 899 - 914
  • [3] Dose Reduction With Dedicated CT Metal Artifact Reduction Algorithm: CT Phantom Study
    Subhas, Naveen
    Pursyko, Camilla P.
    Polster, Joshua M.
    Obuchowski, Nancy A.
    Primak, Andrew N.
    Dong, Frank F.
    Herts, Brian R.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2018, 210 (03) : 593 - 600
  • [4] Performance evaluation of iterative reconstruction algorithms for achieving CT radiation dose reduction - a phantom study
    Dodge, Cristina T.
    Tamm, Eric P.
    Cody, Dianna D.
    Liu, Xinming
    Jensen, Corey T.
    Wei, Wei
    Kundra, Vikas
    Rong, X. John
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2016, 17 (02): : 511 - 531
  • [5] Dose reduction and image quality in CT examinations using an iterative reconstruction algorithm: a phantom study
    Guariglia, S.
    Meliado, G.
    Zivelonghi, E.
    Pinali, L.
    Montemezzi, S.
    Cavedon, C.
    BIOMEDICAL PHYSICS & ENGINEERING EXPRESS, 2015, 1 (04):
  • [6] Dose reduction with adaptive statistical iterative reconstruction for paediatric CT: phantom study and clinical experience on chest and abdomen CT
    Gay, F.
    Pavia, Y.
    Pierrat, N.
    Lasalle, S.
    Neuenschwander, S.
    Brisse, H. J.
    EUROPEAN RADIOLOGY, 2014, 24 (01) : 102 - 111
  • [7] Dose reduction with adaptive statistical iterative reconstruction for paediatric CT: phantom study and clinical experience on chest and abdomen CT
    F. Gay
    Y. Pavia
    N. Pierrat
    S. Lasalle
    S. Neuenschwander
    H. J. Brisse
    European Radiology, 2014, 24 : 102 - 111
  • [8] Iterative metal artifact reduction improves dose calculation accuracy Phantom study with dental implants
    Maerz, Manuel
    Mittermair, Pia
    Krauss, Andreas
    Koelbl, Oliver
    Dobler, Barbara
    STRAHLENTHERAPIE UND ONKOLOGIE, 2016, 192 (06) : 403 - 413
  • [9] Six iterative reconstruction algorithms in brain CT: a phantom study on image quality at different radiation dose levels
    Love, A.
    Olsson, M-L
    Siemund, R.
    Stalhammar, F.
    Bjorkman-Burtscher, I. M.
    Soderberg, M.
    BRITISH JOURNAL OF RADIOLOGY, 2013, 86 (1031):
  • [10] Iterative CT reconstruction of real data with metal artifact reduction
    Hamelin, Benoit
    Goussard, Yves
    Gendron, David
    Dussault, Jean-Pierre
    Cloutier, Guy
    Beaudoin, Gilles
    Soulez, Gilles
    2008 IEEE INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING: FROM NANO TO MACRO, VOLS 1-4, 2008, : 1453 - +