Microwave ablation for atrial fibrillation: Dose-response curves in the cardioplegia-arrested and beating heart

被引:37
|
作者
Gaynor, SL [1 ]
Byrd, GD [1 ]
Diodato, MD [1 ]
Ishii, Y [1 ]
Lee, AM [1 ]
Prasad, SM [1 ]
Gopal, J [1 ]
Schuessler, RB [1 ]
Damiano, RJ [1 ]
机构
[1] Washington Univ, Sch Med, Div Cardiothorac Surg, Dept Surg, St Louis, MO 63110 USA
来源
ANNALS OF THORACIC SURGERY | 2006年 / 81卷 / 01期
关键词
D O I
10.1016/j.athoracsur.2005.06.062
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background. Microwave ablation has been used to replace the traditional incisions used in the surgical treatment of atrial fibrillation. However, dose-response curves have not been established in surgically relevant models. The purpose of this study was to develop dose-response curves for the Flex 10 (Guidant, Inc) microwave device in both the acute cardioplegia-arrested heart and on the beating heart. Methods. Twelve domestic pigs (40 to 45 kg) were subjected to microwave ablation in either the arrested (n = 6) or beating heart (n = 6). The cardioplegia-arrested heart was maintained at 10 degrees to 15 degrees C while six atrial endocardial and seven right ventricular epicardial lesions were created in each animal. On the beating heart, six right atrial and seven ventricular epicardial lesions were created. Ablations were performed for 15, 30, 45, 60, 90,120, and 150 seconds (65 W, 2.45 GHz). The tissue was stained with 2,3,5-triphenyl-tetrazolium chloride, and sectioned at 5-mm intervals. Lesion depth and width were determined from digital micrographs. Results. Mean atrial wall thickness was 2.8 mm (range, 1 to 8 mm). In the arrested heart, 94% of atrial lesions were transmural at 45 seconds and 100% were transmural at 90 seconds. In the beating heart, only 20% of atrial lesions were transmural despite prolonged ablation times (90 seconds). Ventricular lesion width and depth increased with duration of application, and were similar on the arrested and beating hearts. Conclusions. Microwave ablation produces linear dose-response curves. Transmural lesions can be reliably produced on the arrested heart, but not consistently on the beating heart.
引用
收藏
页码:72 / 77
页数:6
相关论文
共 50 条
  • [1] Dose response curves for microwave ablation in the cardioplegia-arrested porcine heart
    Gaynor, SL
    Byrd, GD
    Diodato, MD
    Ishii, Y
    Lee, AM
    Prasad, SM
    Gopal, J
    Berube, D
    Schuessler, RB
    Damiano, RJ
    HEART SURGERY FORUM, 2005, 8 (04): : E269 - E274
  • [2] Dose response curves for microwave ablation in the cardioplegia-arrested porcine heart
    Gaynor, SL
    Byrd, GD
    Diodato, MD
    Ishii, Y
    Lee, AM
    Prasad, SM
    Gopal, J
    Berube, D
    Schuessler, RB
    Damiano, RJ
    HEART SURGERY FORUM, 2005, 8 (05): : E331 - E336
  • [3] Beating-heart surgical treatment of atrial fibrillation with microwave ablation
    Maessen, JG
    Nijs, JFMA
    Smeets, JLRM
    Vainer, J
    Mochtar, B
    ANNALS OF THORACIC SURGERY, 2002, 74 (04): : S1307 - S1311
  • [4] Surgical ablation for atrial fibrillation: The efficacy of a novel bipolar pen device in the cardioplegically arrested and beating heart
    Sakamoto, Shun-ichiro
    Voeller, Rochus K.
    Melby, Spencer J.
    Lall, Shelly C.
    Chang, Nai-lun
    Schuessler, Richard B.
    Damiano, Ralph J., Jr.
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2008, 136 (05): : 1295 - 1301
  • [5] Epicardial microwave ablation on the beating heart for atrial fibrillation: The dependency of lesion depth on cardiac output
    Melby, Spencer J.
    Zierer, Andreas
    Kaiser, Scott P.
    Schuessler, Richard B.
    Damiano, Ralph J., Jr.
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2006, 132 (02): : 355 - 360
  • [6] Surgical ablation of lone atrial fibrillation on the beating heart: the chaos continues
    Damiano, Ralph J.
    EUROPACE, 2010, 12 (03): : 297 - 298
  • [7] Epicardial ablation of atrial fibrillation on the beating heart without cardiopulmonary bypass
    Mazzitelli, D
    Park, CH
    Park, KY
    Benetti, FJ
    Lange, R
    ANNALS OF THORACIC SURGERY, 2002, 73 (01): : 320 - 321
  • [8] BMI and atrial fibrillation recurrence post catheter ablation: A dose-response meta-analysis
    Pranata, Raymond
    Henrina, Joshua
    Yonas, Emir
    Putra, Iwan C. S.
    Cahyadi, Irvan
    Lim, Michael A.
    Munawar, Dian A.
    Munawar, Muhammad
    EUROPEAN JOURNAL OF CLINICAL INVESTIGATION, 2021, 51 (06)
  • [9] Resting Heart Rate and the Risk of Atrial Fibrillation A Dose-Response Analysis of Cohort Studies
    Liu, Xiao
    Guo, Ninghong
    Zhu, Wengen
    Zhou, Quan
    Liu, Menglu
    Chen, Chen
    Yuan, Ping
    Wan, Rong
    Hong, Kui
    INTERNATIONAL HEART JOURNAL, 2019, 60 (04) : 805 - 811
  • [10] Approaching a Paradigm Shift: Endoscopic Ablation of Lone Atrial Fibrillation on the Beating Heart
    Weimar, Timo
    Vosseler, Martina
    Czesla, Markus
    Boscheinen, Margaretha
    Hemmer, Wolfgang B.
    Doll, Kai-Nicolas
    ANNALS OF THORACIC SURGERY, 2012, 94 (06): : 1886 - 1893