A comparison of the growth of open-set speech perception between the Nucleus 22 and Nucleus 24 cochlear implant systems

被引:0
|
作者
Waltzman, SB [1 ]
Cohen, NL [1 ]
Roland, JT [1 ]
机构
[1] NYU, Sch Med, Dept Otolaryngol, New York, NY 10016 USA
来源
AMERICAN JOURNAL OF OTOLOGY | 1999年 / 20卷 / 04期
关键词
open-set speech perception; cochlear implants; deafness;
D O I
暂无
中图分类号
R76 [耳鼻咽喉科学];
学科分类号
100213 ;
摘要
Objective: To compare the short-term development of open-set speech perception between implementations of the spectral peak (SPEAK) strategy in adults using the Nucleus 22 (N22) Spectra processor and the Nucleus 24 (N24) system with the SPrint processor. Study Design: Two sets of patients with a follow-up period of 3 months were compared. Setting: This study was conducted at the New York University (NYU) Medical Center. Patients: Thirty-six profoundly hearing-impaired adults were included in this study. Intervention: Sixteen adults received the N22 cochlear implant with the Spectra speech processor and twenty adults received the N24 cochlear implant with the SPrint speech processor. Main Outcome Measures: Open-set speech perception for the patients with N22 implants was evaluated preoperatively and postoperatively using the following measures: NU-6 monosyllabic words, Iowa sentences, and CID sentences. CNC words, CUNY sentences, and HINT sentences were used to assess the patients with N24 implants. Results: Results revealed that the N22 and N24 cochlear implant recipients had significant open-set speech recognition 3 and 6 months after implantation. The apparent favorable absolute scores for the patients with N24 implants were equalized when a multivariate analysis was performed to account for their younger age at time of implantation and shorter length of deafness. Conclusions: The growth of open-set word and sentence recognition in similar between the N22 and N24 cochlear implants. Longitudinal studies are needed to determine if higher ceiling scores are present in the N24. Further exploration of monopolar versus bipolar stimulation is warranted.
引用
收藏
页码:435 / 441
页数:7
相关论文
共 50 条
  • [1] Comparison of speech perception performance between the Nucleus 24 and Nucleus 24 Contour cochlear implant systems
    Bacciu, A
    Pasanisi, E
    Vincenti, V
    Guida, M
    Barbot, A
    Berghenti, M
    Forli, F
    Berrettini, S
    Bacciu, S
    ACTA OTO-LARYNGOLOGICA, 2004, 124 (10) : 1155 - 1158
  • [2] Speech Perception and Audiometry Thresholds in Nucleus Cochlear 22 and Nucleus 24 Implant Users
    Samuel, Paola Angelica
    Schmidt Goffi Gomez, Maria Valeria
    Befi Lopes, Debora Maria
    Matas, Carla Gentile
    Tsuji, Robinson Koji
    de Brito Neto, Rubens Vuono
    Bento, Ricardo Ferreira
    INTERNATIONAL ARCHIVES OF OTORHINOLARYNGOLOGY, 2010, 14 (03) : 331 - 337
  • [3] Multicenter evaluations of speech perception in adults and children with the Nucleus (Cochlear) 22-channel cochlear implant
    Clark, GM
    Dowell, RC
    Cowan, RS
    Pyman, BC
    Webb, RL
    TRANSPLANTS AND IMPLANTS IN OTOLOGY - III, PROCEEDINGS, 1996, : 353 - 363
  • [4] Factors contributing to limited open-set speech perception in children who use a cochlear implant
    Gordon, KA
    Daya, H
    Harrison, RV
    Papsin, BC
    INTERNATIONAL JOURNAL OF PEDIATRIC OTORHINOLARYNGOLOGY, 2000, 56 (02) : 101 - 111
  • [5] THE EFFECTS OF LIMITING THE NUMBER OF NUCLEUS 22 COCHLEAR IMPLANT ELECTRODES PROGRAMMED ON SPEECH-PERCEPTION
    GEIER, LL
    NORTON, SJ
    EAR AND HEARING, 1992, 13 (05): : 340 - 348
  • [6] Current speech perception benefits for adults using the nucleus 22-channel cochlear implant
    Hollow, R
    Plant, K
    Larratt, M
    Skok, M
    Whitford, L
    Dowell, R
    Clark, G
    COCHLEAR IMPLANTS, 1996, : 249 - 253
  • [7] Speech perception by children with the clarion (CIS) or nucleus 22 (SPEAK) cochlear implant or hearing aids
    Meyer, TA
    Svirsky, MA
    ANNALS OF OTOLOGY RHINOLOGY AND LARYNGOLOGY, 2000, 109 (12): : 49 - 51
  • [8] Speech perception as a function of electrical stimulation rate: Using the nucleus 24 cochlear implant system
    Vandali, AE
    Whitford, LA
    Plant, KL
    Clarke, GM
    EAR AND HEARING, 2000, 21 (06): : 608 - 624
  • [9] Open-set speech perception performance of older children with cochlear implantation
    Kim, L. S.
    Lee, Y. M.
    Huh, M. J.
    Lee, M. Y.
    Proceedings of the 5th Asia Pacific Symposium on Cochlear Implant and Related Sciences, 2005, : 121 - 123
  • [10] OPEN-SET MINIMUM AUDITORY CAPABILITY SCORES FOR HOUSE AND NUCLEUS COCHLEAR PROSTHESES
    MANGHAM, CA
    KUPRENAS, SV
    AMERICAN JOURNAL OF OTOLOGY, 1989, 10 (04): : 263 - 266