Safety and Feasibility of Robotic Percutaneous Coronary Intervention PRECISE (Percutaneous Robotically-Enhanced Coronary Intervention) Study

被引:223
|
作者
Weisz, Giora [1 ]
Metzger, D. Christopher [2 ]
Caputo, Ronald P. [3 ]
Delgado, Juan A. [4 ]
Marshall, J. Jeffrey [5 ]
Vetrovec, George W. [6 ]
Reisman, Mark [7 ]
Waksman, Ron [8 ]
Granada, Juan F. [4 ]
Novack, Victor [9 ]
Moses, Jeffrey W. [1 ]
Carrozza, Joseph P. [10 ]
机构
[1] Columbia Univ, Med Ctr, Ctr Intervent Vasc Therapy, New York Presbyterian Hosp, New York, NY 10032 USA
[2] Wellmont Holston Valley, Kingsport, TN USA
[3] St Josephs Hosp, Syracuse, NY USA
[4] Corb Cardio Neurovasc Inst, Medellin, Colombia
[5] Northeast Georgia Heart Ctr, Gainesville, GA USA
[6] Virginia Commonwealth Univ, Richmond, VA USA
[7] Swedish Heart & Vasc Inst, Seattle, WA USA
[8] Washington Heart Ctr, Washington, DC USA
[9] Soroka Univ, Med Ctr, Clin Res Ctr, Beer Sheva, Israel
[10] St Elizabeths Med Ctr, Boston, MA USA
关键词
angioplasty; robotic-enhanced PCI; stent; CARDIOLOGISTS; HAZARDS;
D O I
10.1016/j.jacc.2012.12.045
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objectives The aim of this study was to evaluate the safety as well as the clinical and technical effectiveness of robotic-assisted percutaneous coronary intervention. Background Robotic systems have been suggested to enhance the performance of cardiovascular procedures, as well as to provide protection from the occupational hazards that are associated with interventional practice. Methods Patients with coronary artery disease and clinical indications for percutaneous intervention were enrolled. The coronary intervention was performed with the CorPath 200 robotic system, which consists of a remote interventional cockpit and a bedside disposable cassette that enables the operator to advance, retract, and rotate guidewires and catheters. The primary endpoints were clinical procedural success, defined as <30% residual stenosis at the completion of the robotic-assisted procedure without major adverse cardiovascular events within 30 days, and device technical success, defined as the successful manipulation of the intracoronary devices using the robotic system only. Results A total of 164 patients were enrolled at 9 sites. Percutaneous coronary intervention was completed successfully without conversion to manual operation, and device technical success was achieved in 162 of 164 patients (98.8%). There were no device-related complications. Clinical procedural success was achieved in 160 of 164 patients (97.6%), whereas 4 (2.4%) had periprocedural non-Q-wave myocardial infarctions. No deaths, strokes, Q-wave myocardial infarctions, or revascularization occurred in the 30 days after the procedures. Radiation exposure for the primary operator was 95.2% lower than the levels found at the traditional table position. Conclusions This pivotal multicenter study with a robotic-enhanced coronary intervention system demonstrated the safety and feasibility of the system. The robotic remote-control procedure met the expected technical and clinical performance, with significantly lower radiation exposure to the operator. (Evaluation of the Safety and Effectiveness of the CorPath 200 System in Percutaneous Coronary Interventions [PCI] [ PRECISE]; NCT01275092) (J Am Coll Cardiol 2013;61:1596-600) (c) 2013 by the American College of Cardiology Foundation
引用
收藏
页码:1596 / 1600
页数:5
相关论文
共 50 条
  • [1] Demonstration of the Safety and Feasibility of Robotically Assisted Percutaneous Coronary Intervention in Complex Coronary Lesions Results of the CORA-PCI Study (Complex Robotically Assisted Percutaneous Coronary Intervention)
    Mahmud, Ehtisham
    Naghi, Jesse
    Ang, Lawrence
    Harrison, Jonathan
    Behnamfar, Omid
    Pourdjabbar, Ali
    Reeves, Ryan
    Patel, Mitul
    JACC-CARDIOVASCULAR INTERVENTIONS, 2017, 10 (13) : 1320 - 1327
  • [2] Feasibility of Complex Robotic Percutaneous Coronary Intervention
    Dominguez, Arturo
    Reeves, Ryan
    Bahadorani, John
    Patel, Mitul
    Mahmud, Ehtisham
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2014, 64 (11) : B44 - B44
  • [3] Remote robotic percutaneous coronary intervention: An animal feasibility study
    Eleid, Mackram F.
    Zheng, Park P.
    Gulati, Rajiv
    Bergman, Per
    Kottenstette, Nicholas
    Li, Yao
    Lerman, Amir
    Sandhu, Gurpreet S.
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2021, 97 (03) : E274 - E279
  • [4] Safety and feasibility of intravascular ultrasound-guided robotic percutaneous coronary intervention
    Kimura, Takumi
    Koeda, Yorihiko
    Ishida, Masaru
    Numahata, Wataru
    Yamaya, Shohei
    Kikuchi, Sayaka
    Ishisone, Takenori
    Goto, Iwao
    Itoh, Tomonori
    Morino, Yoshihiro
    CORONARY ARTERY DISEASE, 2023, 34 (07) : 463 - 469
  • [5] SAFETY AND FEASIBILITY OF ROBOTIC ASSISTED PERCUTANEOUS CORONARY INTERVENTION COMPARED TO STANDARD PERCUTANEOUS CORONARY INTERVENTION- A SYSTEMATIC REVIEW AND META-ANALYSIS
    Sharma, Purnima
    Tripathi, Byomesh
    Bhat, Sangeeta
    Mishra, Rohi
    Patel, Smit
    Klein, Jason
    Kapadia, Saurav
    Verma, Divya Ratan
    Deshmukh, Abhishek
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2021, 77 (18) : 1054 - 1054
  • [6] Safety and feasibility of robotic assisted percutaneous coronary intervention compared to standard percutaneous coronary intervention- a systematic review and meta-analysis
    Tripathi, Byomesh
    Sharma, Purnima
    Arora, Shilpkumar
    Murtaza, Malik
    Singh, Aanandita
    Solanki, Dhanshree
    Kapadia, Saurabh
    Sharma, Akshat
    Pershad, Ashish
    INDIAN HEART JOURNAL, 2021, 73 (05) : 549 - 554
  • [7] Complex robotic-enhanced percutaneous coronary intervention
    Kapur, Vishal
    Smilowitz, Nathaniel R.
    Weisz, Giora
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2014, 83 (06) : 915 - 921
  • [8] Safety and Feasibility of Intravascular Ultrasound Guided Robotic Percutaneous Coronary Intervention in Stable Angina
    Kimura, Takumi
    Koeda, Yorihiko
    Ishida, Masaru
    Yamaya, Shohei
    Tsuji, Keiko
    Kawakami, Jun
    Ishisone, Takenori
    Goto, Iwao
    Itoh, Tomonori
    Morino, Yoshihiro
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2020, 76 (17) : B80 - B80
  • [9] Feasibility and Safety of CT-Guided Percutaneous Coronary Intervention
    Lim, Michael C. I.
    De larrazabal, Catherine G.
    Devaraj, Levinia M.
    CIRCULATION, 2010, 122 (02) : E332 - E332
  • [10] Dynamic coronary roadmapping during percutaneous coronary intervention: a feasibility study
    Kerstin Piayda
    Laura Kleinebrecht
    Shazia Afzal
    Roland Bullens
    Iris ter Horst
    Amin Polzin
    Verena Veulemans
    Lisa Dannenberg
    Anna Christina Wimmer
    Christian Jung
    Florian Bönner
    Malte Kelm
    Katharina Hellhammer
    Tobias Zeus
    European Journal of Medical Research, 23