Metallosis after contemporary metal-on-metal total hip arthroplasty - Five to nine-year follow-up

被引:243
|
作者
Korovessis, P. [1 ]
Petsinis, G. [1 ]
Repanti, M. [1 ]
Repantis, T. [1 ]
机构
[1] Gen Hosp Agios Andreas, Dept Orthopaed, Patras 26224, Greece
来源
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME | 2006年 / 88A卷 / 06期
关键词
D O I
10.2106/JBJS.D.02916
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Authors of recent studies have reported early periprosthetic osteolysis in patients who have been treated with a contemporary metal-on-metal total hip arthroplasty and have suggested that metal hypersensitivity associated with an immunologic response to metal may be of etiologic importance. We evaluated the results and histologic findings in patients who had undergone revision of a failed contemporary metal-on-metal total hip arthroplasty. Methods: Two hundred and seventeen total hip arthroplasties (SL-Plus stem and Bicon-Plus cup) with a Sikomet metal-on-metal articulation were implanted in 194 consecutive patients, and the results were retrospectively reviewed at a mean of seventy-seven months postoperatively. Clinical follow-up with the Harris hip score and plain radiographic evaluation were performed. Periprosthetic tissues from fourteen hips that had undergone revision arthroplasty were subjected to histologic analysis. Results: The mean Harris hip score improved from 45 points preoperatively to 88 points at the final evaluation. Fourteen hips (6.5%) were revised: nine because of aseptic loosening, two because of technical failure, and three because of septic failure. Histologic examination of the retrieved periprosthetic tissues from the eleven patients who had undergone revision because of aseptic loosening or technical failure showed metallosis and extensive lymphocytic and plasma-cell infiltration around the metal debris. With removal of the component because of aseptic loosening as the end point, survivorship was 93% for the stem and 98% for the cup. Conclusions: Our findings are in agreement with those in recent publications and support the possibility that periprosthetic osteolysis and aseptic loosening in hips with a metal-on-metal articulation are possibly associated with hypersensitivity to metal debris. Prospective, comparative, randomized long-term studies are necessary to determine the cause(s) of loosening of prostheses with this particular articulation.
引用
收藏
页码:1183 / 1191
页数:9
相关论文
共 50 条
  • [1] Metal-on-Metal Total Hip Arthroplasty Five- to 11-Year Follow-Up
    Nikolaou, Vassilios S.
    Petit, Alain
    Debiparshad, Kevin
    Huk, Olga L.
    Zukor, David J.
    Antoniou, John
    BULLETIN OF THE HOSPITAL FOR JOINT DISEASES, 2011, 69 : S77 - S83
  • [2] Poor Patient Follow-up After Metal-on-Metal Total Hip Arthroplasty
    Costales, Timothy G.
    Greenwell, Patrick H.
    Shield, William, III
    Chapman, Danielle M.
    Griffin, William L.
    Dalury, David F.
    ORTHOPEDICS, 2022, 45 (04) : E196 - +
  • [3] Metal-on-Metal Total Hip Arthroplasty at Five to Twelve Years Follow-Up: A Concise Follow-Up of a Previous Report
    Greiner, Justin J.
    Callaghan, John J.
    Bedard, Nicholas A.
    Liu, Steve S.
    Goetz, Devon D.
    Mahoney, Craig R.
    JOURNAL OF ARTHROPLASTY, 2016, 31 (08): : 1773 - 1778
  • [4] Long-Term Results of a Contemporary Metal-on-Metal Total Hip Arthroplasty A 10-Year Follow-Up Study
    Neumann, Daniel R. P.
    Thaler, Christoph
    Hitzl, Wolfgang
    Huber, Monika
    Hofstaedter, Thomas
    Dorn, Ulrich
    JOURNAL OF ARTHROPLASTY, 2010, 25 (05): : 700 - 708
  • [5] Metal-on-metal total hip joint replacement: a minimum follow-up of five years
    Sharma, S.
    Vassan, U.
    Bhamra, M. S.
    HIP INTERNATIONAL, 2007, 17 (02) : 70 - 77
  • [6] Five-year follow-up of a prospective randomised trial comparing ceramic-on-metal and metal-on-metal bearing surfaces in total hip arthroplasty
    Schouten, R.
    Malone, A. A.
    Frampton, C. M.
    Tiffen, C.
    Hooper, G.
    BONE & JOINT JOURNAL, 2017, 99B (10): : 1298 - 1303
  • [7] Small diameter metal-on-metal total hip arthroplasty at 13 years - a follow-up study
    Tardy, N.
    Maqdes, A.
    Boisrenoult, P.
    Beaufils, P.
    Oger, P.
    ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2015, 101 (08) : 929 - 936
  • [8] A prospective comparative study of hip resurfacing arthroplasty and large-diameter head metal-on-metal total hip arthroplasty in younger patients—a minimum of five year follow-up
    Ran Tao
    Fan Liu
    Ya-ke Liu
    Yue Lu
    Hua Xu
    Yi Cao
    Zhen-yu Zhou
    Wei Wang
    International Orthopaedics, 2018, 42 : 2323 - 2327
  • [9] Long-term follow-up and metal ion trend of patients with metal-on-metal total hip arthroplasty
    Bernstein, Mitchell
    Desy, Nicholas M.
    Petit, Alain
    Zukor, David J.
    Huk, Olga L.
    Antoniou, John
    INTERNATIONAL ORTHOPAEDICS, 2012, 36 (09) : 1807 - 1812
  • [10] Long-term follow-up and metal ion trend of patients with metal-on-metal total hip arthroplasty
    Mitchell Bernstein
    Nicholas M. Desy
    Alain Petit
    David J. Zukor
    Olga L. Huk
    John Antoniou
    International Orthopaedics, 2012, 36 : 1807 - 1812