摘要
With wind penetration levels increasing in power systems, it will be necessary for system planners to have a better understanding of their systems and make best use of the mitigation tools that already present in the system. Particularly, in order to maintain rotor angle stability with high penetrations of wind generation, it will be critical for system planners to utilize the built-in reactive power controls of modern variable speed wind turbines. This paper develops a comprehensive system planning methodology that assesses the characteristics of a given system and identifies nodes that are critical to the rotor stability of the system. This is achieved by utilizing small-signal analysis to identify wind farm locations that participate significantly from an electro-mechanical perspective and implemented by using the built-in controls of the turbine to control voltage at these nodes. By controlling the voltage at these specific locations, the magnitude and damping of oscillatory modes that arise following a loss of a generator can be significantly improved. Furthermore, it will demonstrate that the selective implementation of reactive power control does not degrade the voltage stability of the system for a large system disturbance.
引用
收藏
页码:2950 / 2958
页数:9
相关论文
共 31 条
[1]  
Ackermann Thomas., 2003, WIND POWER POWER SYS
[2]  
[Anonymous], 1994, Power System Voltage Stability
[3]  
[Anonymous], MODELING GE WIND TUR
[4]  
[Anonymous], DSATOOLS US MAN
[5]  
[Anonymous], 2011, IEEE PES INNOV SMART
[6]  
Bernard S., 2005, P IEEE POW ENG SOC G
[7]  
Camm E. H., 2009, 2009 IEEE POW EN SOC, P1, DOI [10.1109/pes.2009.5275322, 10.1109/PES.2009.5275322, DOI 10.1109/PES.2009.5275322]
[8]  
Fuentes J. A., 2007, P INT C REN EN POW Q
[9]   Impact of Increased Penetration of DFIG-Based Wind Turbine Generators on Transient and Small Signal Stability of Power Systems [J].
Gautam, Durga ;
Vittal, Vijay ;
Harbour, Terry .
IEEE TRANSACTIONS ON POWER SYSTEMS, 2009, 24 (03) :1426-1434
[10]   Real-time analysis of the transient response improvement of fixed-speed wind farms by using a reduced-scale STATCOM prototype [J].
Gaztanaga, Haizea ;
Etxeberria-Otadui, Ion ;
Ocnasu, Dan ;
Bacha, Seddik .
IEEE TRANSACTIONS ON POWER SYSTEMS, 2007, 22 (02) :658-666