Effect of the moment transfer efficiency of a beam web on deformation capacity at box column-to-H beam connections

被引:36
|
作者
Kim, Young-Ju [1 ]
Oh, Sang-Hoon [1 ]
机构
[1] Res Inst Ind Sci & Technol, Kyonggi Do 445810, South Korea
关键词
box column; moment transfer efficiency; strain concentration; deformation capacity; BEHAVIOR; TESTS;
D O I
10.1016/j.jcsr.2006.02.009
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This paper investigates the effect of moment transfer efficiency of a beam web on deformation capacity at beam-to-column connections. Non-linear finite element analysis of five connection models was conducted. Analytical results showed that the moment transfer efficiency of the connection with a box column was poor when compared to a connection with an H-column; this was due to the out-of-plane deformation of the column flange. Based on previous test data, analytical results were compared with experimental results. Analytical and experimental results showed that the deformation capacity of the connection with a box column decreased due to the poor moment transfer efficiency of a beam web, followed by strain concentration at the beam flange. (c) 2006 Elsevier Ltd. All rights reserved.
引用
收藏
页码:24 / 36
页数:13
相关论文
共 50 条
  • [1] TESTS OF BEAM-TO-COLUMN WEB MOMENT CONNECTIONS
    Rentschler, Glenn P.
    Chen, Wai F.
    Driscoll, George C.
    1980, 106 (05): : 1005 - 1022
  • [2] STEEL BEAM-TO-COLUMN MOMENT CONNECTIONS .2. WEB MOMENT CONNECTIONS
    CHEN, WF
    LUI, EM
    SOLID MECHANICS ARCHIVES, 1987, 12 (01): : 1 - 52
  • [3] BEAM-TO-COLUMN MOMENT CONNECTIONS
    GRUNDY, P
    THOMAS, IR
    BENNETTS, ID
    JOURNAL OF THE STRUCTURAL DIVISION-ASCE, 1980, 106 (01): : 313 - 330
  • [4] BEAM-TO-COLUMN MOMENT CONNECTIONS
    KRISHNAMURTHY, N
    JOURNAL OF THE STRUCTURAL DIVISION-ASCE, 1980, 106 (12): : 2573 - 2574
  • [5] STEEL BEAM-TO-COLUMN MOMENT CONNECTIONS: PART II. WEB MOMENT CONNECTIONS.
    Chen, W.F.
    Lui, E.M.
    SM archives, 1987, 12 (01): : 1 - 52
  • [6] Effect of continuity-plate alignment on the capacity of welded beam-to-column moment connections
    Norwood, J.
    Prinz, G. S.
    ENGINEERING STRUCTURES, 2019, 198
  • [7] Deformation capacity of moment connection with box column
    Yoon, M. H.
    Kim, Y. J.
    Oh, S. H.
    Ryu, H. S.
    Stessa 2006, 2006, : 371 - 376
  • [8] BEAM-TO-COLUMN MOMENT CONNECTIONS - DISCUSSION
    KOSTRO, G
    JOURNAL OF THE STRUCTURAL DIVISION-ASCE, 1980, 106 (11): : 2357 - 2360
  • [9] The moment capacity of welded-bolted beam to column connections in steel framework
    School of Civil Engineering, Xi'an Univ. of Arch. and Tech., Xi'an 710055, China
    不详
    不详
    Xi'an Jianzhu Keji Daxue Xuebao, 2008, 4 (491-498):
  • [10] Deformation-based capacity design of RCS beam-column connections
    Shen, Hong-Xia
    Gu, Qiang