Microfabricated high temperature sensing platform dedicated to scanning thermal microscopy (SThM)

被引:12
|
作者
Nguyen, T. P. [1 ]
Lemaire, E. [2 ]
Euphrasie, S. [1 ]
Thiery, L. [1 ]
Teyssieux, D. [1 ]
Briand, D. [2 ]
Vairac, P. [1 ]
机构
[1] Univ Bourgogne Franche Comte, Inst FEMTO ST UMR 6174, CNRS, ENSMM, Besancon, France
[2] Ecole Polytech Fed Lausanne, Microsyst Space Technol Lab, Neuchatel, Switzerland
关键词
Calibration; SThM; Micro-Hotplate; Temperature measurement; THERMOMETRY;
D O I
10.1016/j.sna.2018.04.011
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The monitoring of heat flux is becoming more and more critical for many materials and structures approaching nanometric dimensions. Scanning Thermal Microscopy (SThM) is one of the tools available for thermal measurement at the nanoscale and requires calibration. Here we report on a micro-hotplate device made of a platinum heater suspended on thin silicon nitride (SiN) membranes integrating specific features for SThM calibration. These heated reference samples can include a localized resistive temperature sensors (RTD) or standalone platinum membranes (typically 10 x 10 mu m(2)) on which the temperature can be measured precisely. This functional area is dedicated to (1) estimate the thermal resistance between the SThM tip and hot surface contact; and to (2) evaluate the perturbation induced by the probe on the heat dissipation when the contact measurement is performed. The thermal design of these low-power calibration chips, their fabrication, including sensitive RTDs patterned using e-beam technology, as well as their electro-thermal and electro-mechanical characterizations are presented. Robust operation of the chips up to 500 degrees C has been demonstrated with their membrane mechanically stable up to 250 degrees C and a low-power consumption of 16 mW at this operating temperature. The temperature mapping of the active areas was performed using two physical principles: local SThM temperature measurement using a thermocouple-based micro-probe and optical imaging using Near-Infrared (NIR) microscopy. Measurements coupling on one hand SThM probe and the integrated RTD and, on the other hand, SThM probe with optical imaging, validated the functionality of the calibration chips. The latter open new perspectives in the calibration of SThM probes. (C) 2018 Elsevier B.V. All rights reserved.
引用
收藏
页码:109 / 118
页数:10
相关论文
共 50 条
  • [1] Sensing thermal conductivity and structural effects at the nanoscale by scanning thermal microscopy (SThM)
    Chirtoc, M.
    Gibkes, J.
    Antoniow, J. -S.
    Henry, J. -F.
    Neubauer, E.
    Bein, B.
    Pelzl, J.
    JOURNAL DE PHYSIQUE IV, 2006, 137 : 265 - 271
  • [2] Temperature profiling with highest spatial and temperature resolution by means of scanning thermal microscopy (SThM)
    Fiege, GM
    Cramer, RM
    Balk, L
    Reineke, F
    ISTFA '97 - PROCEEDINGS OF THE 23RD INTERNATIONAL SYMPOSIUM FOR TESTING AND FAILURE ANALYSIS, 1997, : 51 - 56
  • [3] New methods for calibrated Scanning Thermal Microscopy (SThM)
    Dobson, Phillip S.
    Weaver, John M. R.
    Mills, Gordon
    2007 IEEE SENSORS, VOLS 1-3, 2007, : 708 - 711
  • [4] A Review on Principles and Applications of Scanning Thermal Microscopy (SThM)
    Zhang, Yun
    Zhu, Wenkai
    Hui, Fei
    Lanza, Mario
    Borca-Tasciuc, Theodorian
    Rojo, Miguel Munoz
    ADVANCED FUNCTIONAL MATERIALS, 2020, 30 (18)
  • [5] Failure analysis of integrated devices by Scanning Thermal Microscopy (SThM)
    Fiege, GBM
    Feige, V
    Phang, JCH
    Maywald, M
    Gorlich, S
    Balk, LJ
    MICROELECTRONICS RELIABILITY, 1998, 38 (6-8) : 957 - 961
  • [6] Microfabricated resistive high-sensitivity nanoprobe for scanning thermal microscopy
    Wielgoszewski, G.
    Sulecki, P.
    Gotszalk, T.
    Janus, P.
    Szmigiel, D.
    Grabiec, P.
    Zschech, E.
    JOURNAL OF VACUUM SCIENCE & TECHNOLOGY B, 2010, 28 (06): : C6N7 - C6N11
  • [7] Investigation of the accuracy and spatial resolution of Scanning Thermal Microscopy (SThM) technique
    Lo, Hsinyi
    Liu, Wenjun
    Asheghi, Mehdi
    HT2005: Proceedings of the ASME Summer Heat Transfer Conference 2005, Vol 1, 2005, : 71 - 77
  • [8] Studying thermal conductivity of wood at cell wall level by scanning thermal microscopy (SThM)
    Vay, Oliver
    Obersriebnig, Michael
    Mueller, Ulrich
    Konnerth, Johannes
    Gindl-Altmutter, Wolfgang
    HOLZFORSCHUNG, 2013, 67 (02) : 155 - 159
  • [9] Development of a Novel Scanning Thermal Microscopy (SThM) Method to Measure the Thermal Conductivity of Biological Cells
    Nakanishi, Kouichi
    Kogure, Akinori
    Kuwana, Ritsuko
    Takamatsu, Hiromu
    Ito, Kiyoshi
    BIOCONTROL SCIENCE, 2017, 22 (03) : 175 - 180
  • [10] Adhesive penetration of wood cell walls investigated by scanning thermal microscopy (SThM)
    Konnerth, Johannes
    Harper, David
    Lee, Seung-Hwan
    Rials, Timothy G.
    Gindl, Wolfgang
    HOLZFORSCHUNG, 2008, 62 (01) : 91 - 98