Hearing in Noise: The Importance of Coding Strategies-Normal-Hearing Subjects and Cochlear Implant Users

被引:3
|
作者
Cucis, Pierre-Antoine [1 ,2 ]
Berger-Vachon, Christian [3 ,4 ]
Hermann, Ruben [1 ,2 ]
Millioz, Fabien [5 ]
Truy, Eric [1 ,2 ]
Gallego, Stephane [6 ,7 ]
机构
[1] Claude Bernard Lyon1 Univ, CNRS UMR 5292, INSERM U1028, IMPACT, F-69676 Bron, France
[2] Hop Edouard Herriot, ENT & Cervicofacial Surg Dept, F-69003 Lyon, France
[3] Claude Bernard Lyon1 Univ, Brain Dynam & Cognit DYCOG, INSERM U1028, CNRS UMR 5292, F-69676 Bron, France
[4] Claude Bernard Lyon1 Univ, CNRS UMR T9406, French Inst Sci & Technol Transport Dev & Network, Biomech & Impact Mech Lab LBMC, F-69675 Bron, France
[5] Claude Bernard Lyon1 Univ, Ctr Res Acquisit & Proc Images Healthcare CREATIS, INSERM U1206, CNRS UMR5220,INSA, F-69621 Lyon, France
[6] Aix Marseille Univ, Sensory & Cognit Neurosci Lab LNSC, CNRS UMR 7260, F-13331 Marseille, France
[7] Claude Bernard Lyon1 Univ, Inst Rehabil Sci & Tech ISTR, F-69373 Lyon 08, France
来源
APPLIED SCIENCES-BASEL | 2019年 / 9卷 / 04期
关键词
cochlear implant; coding strategy; Fixed-Channel; Channel-Picking; vocoder simulation; normal-hearing; SPEECH RECOGNITION; SPECTRAL CHANNELS; ACOUSTIC HEARING; STIMULATION RATE; CIS; NUMBER; SPEAK; IDENTIFICATION; SIMULATIONS; INFORMATION;
D O I
10.3390/app9040734
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Two schemes are mainly used for coding sounds in cochlear implants: Fixed-Channel and Channel-Picking. This study aims to determine the speech audiometry scores in noise of people using either type of sound coding scheme. Twenty normal-hearing and 45 cochlear implant subjects participated in this experiment. Both populations were tested by using dissyllabic words mixed with cocktail-party noise. A cochlear implant simulator was used to test the normal-hearing subjects. This simulator separated the sound into 20 spectral channels and the eight most energetic were selected to simulate the Channel-Picking strategy. For normal-hearing subjects, we noticed higher scores with the Fixed-Channel strategy than with the Channel-Picking strategy in the mid-range signal-to-noise ratios (0 to +6 dB). For cochlear implant users, no differences were found between the two coding schemes but we could see a slight advantage for the Fixed-Channel strategies over the Channel-Picking strategies. For both populations, a difference was observed for the signal-to-noise ratios at 50% of the maximum recognition plateau in favour of the Fixed-Channel strategy. To conclude, in the most common signal-to-noise ratio conditions, a Fixed-Channel coding strategy may lead to better recognition percentages than a Channel-Picking strategy. Further studies are indicated to confirm this.
引用
收藏
页数:16
相关论文
共 50 条
  • [1] Sound Localization in Noise by Normal-Hearing Listeners and Cochlear Implant Users
    Kerber, Stefan
    Seeber, Bernhard U.
    EAR AND HEARING, 2012, 33 (04): : 445 - 457
  • [2] Importance of ipsilateral residual hearing for spatial hearing by bimodal cochlear implant users
    Mathew Thomas
    John J. Galvin
    Qian-Jie Fu
    Scientific Reports, 13
  • [3] Importance of ipsilateral residual hearing for spatial hearing by bimodal cochlear implant users
    Thomas, Mathew
    Galvin, John J. J.
    Fu, Qian-Jie
    SCIENTIFIC REPORTS, 2023, 13 (01)
  • [4] Perception of Pure Tones and Iterated Rippled Noise for Normal Hearing and Cochlear Implant Users
    Penninger, Richard T.
    Chien, Wade W.
    Jiradejvong, Patpong
    Boeke, Emily
    Carver, Courtney L.
    Limb, Charles J.
    TRENDS IN AMPLIFICATION, 2013, 17 (01): : 45 - 53
  • [5] Processing of interaural time differences in normal-hearing subjects and cochlear implant users with FSP and HDCIS coding strategy
    Heidekrueger, N.
    Rahne, T.
    Wagner, L.
    HNO, 2019, 67 (11) : 855 - 862
  • [6] Hebrew Digits in Noise (DIN) Test in Cochlear Implant Users and Normal Hearing Listeners
    Taitelbaum-Swead, Riki
    Fostick, Leah
    AUDIOLOGY RESEARCH, 2024, 14 (03) : 457 - 468
  • [7] Comparison of Music Perception in Bilateral and Unilateral Cochlear Implant Users and Normal-Hearing Subjects
    Veekmans, K.
    Ressel, L.
    Mueller, J.
    Vischer, M.
    Brockmeier, S. J.
    AUDIOLOGY AND NEURO-OTOLOGY, 2009, 14 (05) : 315 - 326
  • [8] Aligning Hearing Aid and Cochlear Implant Improves Hearing Outcome in Bimodal Cochlear Implant Users
    Holtmann, Laura Christine
    Janosi, Anna
    Bagus, Heike
    Scholz, Tim
    Lang, Stephan
    Arweiler-Harbeck, Diana
    Hans, Stefan
    OTOLOGY & NEUROTOLOGY, 2020, 41 (10) : 1350 - 1356
  • [9] Development and applications of alternative methods of segmentation for Mandarin Hearing in Noise Test in normal-hearing listeners and cochlear implant users
    Zhang, Ning
    Liu, Sha
    Xu, Juanjuan
    Liu, Bo
    Qi, Beier
    Yang, Yilin
    Kong, Ying
    Han, Demin
    ACTA OTO-LARYNGOLOGICA, 2010, 130 (07) : 831 - 837
  • [10] Auditory, Visual, and Cognitive Abilities in Normal-Hearing Adults, Hearing Aid Users, and Cochlear Implant Users
    Ceuleers, Dorien
    Keppler, Hannah
    Degeest, Sofie
    Baudonck, Nele
    Swinnen, Freya
    Kestens, Katrien
    Dhooge, Ingeborg
    EAR AND HEARING, 2024, 45 (03): : 679 - 694