Sizing of aerosol in gases other than air using a differential mobility analyzer

被引:16
|
作者
Schmid, O
Trueblood, MB
Gregg, N
Hagen, DE
Whitefield, PD
机构
[1] Univ Missouri, Dept Phys, Rolla, MO 65401 USA
[2] Univ Missouri, Cloud Aerosol Sci Lab, Rolla, MO 65401 USA
[3] Univ Missouri, Dept Chem, Rolla, MO 65401 USA
关键词
D O I
10.1080/027868202753504452
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
The differential mobility analyzer (DMA) is a device that sizes aerosol particles based on their electrical mobility. The relationship between particle size and mobility depends, among other factors, on three gas specific parameters, namely, dynamic viscosity, mean free path, and Cunningham slip correction factor C-c. Provided these parameters are known, DMA theory is expected to be valid independent of gas type. The present study demonstrates the sizing accuracy of DMAs for gases other than air using monodisperse polystyrene latex (PSL) spheres with nominal diameters of 60 nm, 149 nm, and 343 nm in He, Ar, H-2, CO2, and N2O. Eliminating possible systematic errors due to uncertainties in DMA geometry and nominal PSL diameter by normalizing the measured PSL diameters to their respective diameters measured in air, the sheath flow rate Q(sh) and C-c are expected to be the main sources for measurement errors. Since C-c data are lacking for PSL spheres in gases other than air, an expression given by Allen and Raabe (1985b) was used to approximate C-c. The experimental results of the present study are consistent with a 2% accuracy of this expression for C-c, which is considerably better than the 5% accuracy estimated by Rader (1990) for a similar expression for oil drops. Finally, we discuss other aspects of operating a DMA with gases other than air, namely, flow meter calibration and dependence of electrical breakdown voltage on gas type. In the present study a thermal mass flow meter (MFM) was used to measure Q(sh). Calibration of this MFM revealed that the gas specific MFM correction factors (K factors) provided by the technical literature can be highly inaccurate (here between -12% and +31%). More accurate K factors are presented.
引用
收藏
页码:351 / 360
页数:10
相关论文
共 50 条
  • [1] FACILITATED AEROSOL SIZING USING THE DIFFERENTIAL MOBILITY ANALYZER
    ADACHI, M
    OKUYAMA, K
    KOUSAKA, Y
    MOON, SW
    SEINFELD, JH
    AEROSOL SCIENCE AND TECHNOLOGY, 1990, 12 (02) : 225 - 239
  • [2] Differential mobility analyzer for nano particle sizing
    Fissan, H
    Hummes, D
    Pui, D
    SYNTHESIS AND PROCESSING OF NANOCRYSTALLINE POWDER, 1996, : 289 - 297
  • [3] Sizing nanoparticles and ions with a short differential mobility analyzer
    RosellLlompart, J
    Loscertales, IG
    Bingham, D
    delaMora, JF
    JOURNAL OF AEROSOL SCIENCE, 1996, 27 (05) : 695 - 719
  • [4] Sizing of colloidal nanoparticles by electrospray and differential mobility analyzer methods
    Lenggoro, IW
    Xia, B
    Okuyama, K
    de la Mora, JF
    LANGMUIR, 2002, 18 (12) : 4584 - 4591
  • [5] Control of an air siphon nozzle using hydrogen and gases other than air
    Seibert, Michael L.
    Nieh, Sen
    INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2016, 41 (01) : 683 - 689
  • [6] Practical limitations of aerosol separation by a tandem differential mobility analyzer-aerosol particle mass analyzer
    Radney, James G.
    Zangmeister, Christopher D.
    AEROSOL SCIENCE AND TECHNOLOGY, 2016, 50 (02) : 160 - 172
  • [7] Effect of Aerosol Volatility on the Sizing Accuracy of Differential Mobility Analyzers
    Khlystov, Andrey
    AEROSOL SCIENCE AND TECHNOLOGY, 2014, 48 (06) : 604 - 619
  • [8] Determination of Aerosol Particle Size Distribution using Electrical Differential Mobility Analyzer (DMA)
    Fasih-Ramandi, Fatemeh
    Sadigzadeh, Asghar
    Jafari, Mohammad-Javad
    Khodakarim, Soheila
    JOURNAL OF HEALTH AND SAFETY AT WORK, 2021, 11 (01) : 92 - 105
  • [9] LOSS OF ULTRAFINE AEROSOL-PARTICLES IN DIFFERENTIAL MOBILITY ANALYZER
    KOUSAKA, Y
    OKUYAMA, K
    HAYASHI, K
    JOURNAL OF AEROSOL SCIENCE, 1984, 15 (03) : 375 - 376
  • [10] Numerical modeling of the performance of the differential mobility analyzer for nanometer aerosol measurements
    Chen, D.
    Pui, D.Y.H.
    Journal of Aerosol Science, 1995, 26 (Suppl 1):