Disposable Nafion-Coated Single-Walled Carbon Nanotube Test Strip for Electrochemical Quantitative Determination of Acetaminophen in a Finger-Prick Whole Blood Sample

被引:30
|
作者
Wester, Niklas [8 ]
Mikladal, Bjorn F. [1 ]
Varjos, Ilkka [1 ]
Peltonen, Antti [2 ]
Kalso, Eija [3 ,4 ,5 ]
Lilius, Tuomas [3 ,5 ,6 ]
Laurila, Tomi [7 ]
Koskinen, Jari [8 ]
机构
[1] Canatu Oy, Vantaa 01720, Finland
[2] Aalto Univ, Aalto NanoFab, Micronova, Espoo 02150, Finland
[3] Univ Helsinki, Dept Pharmacol, Helsinki 00290, Finland
[4] Univ Helsinki, Dept Anaesthesiol Intens Care & Pain Med, Helsinki 00029, Finland
[5] Helsinki Univ Hosp, Helsinki 00029, Finland
[6] Univ Helsinki, Dept Clin Pharmacol, Helsinki 00290, Finland
[7] Aalto Univ, Dept Elect Engn & Automat, Espoo 02150, Finland
[8] Aalto Univ, Dept Chem & Mat Sci, Espoo 02150, Finland
关键词
SIMULTANEOUS VOLTAMMETRIC DETERMINATION; DOPED DIAMOND ELECTRODE; PARACETAMOL; FILM; SENSOR; ACID; HEPATOTOXICITY; NANOCOMPOSITE; NANOPARTICLES; FABRICATION;
D O I
10.1021/acs.analchem.0c01857
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A disposable electrochemical test strip for the quantitative point-of-care (POC) determination of acetaminophen (paracetamol) in plasma and finger-prick whole blood was fabricated. The industrially scalable dry transfer process of single-walled carbon nanotubes (SWCNTs) and screen printing of silver were combined to produce integrated electrochemical test strips. Nafion coating stabilized the potential of the Ag reference electrode and enabled the selective detection in spiked plasma as well as in whole blood samples. The test strips were able to detect acetaminophen in small 40 mu L samples with a detection limit of 0.8 mu M and a wide linear range from 1 mu M to 2 mM, well within the required clinical range. After a simple 1:1 dilution of plasma and whole blood, a quantitative detection with good recoveries of 79% in plasma and 74% in whole blood was achieved. These results strongly indicate that these electrodes can be used directly to determine the unbound acetaminophen fraction without the need for any additional steps. The developed test strip shows promise as a rapid and simple POC quantitative acetaminophen assay.
引用
收藏
页码:13017 / 13024
页数:8
相关论文
共 3 条
  • [1] Electrochemical Detection of Oxycodone and Its Main Metabolites with Nafion-Coated Single-Walled Carbon Nanotube Electrodes
    Mynttinen, Elsi
    Wester, Niklas
    Lilius, Tuomas
    Kalso, Eija
    Mikladal, Bjorn
    Varjos, Ilkka
    Sainio, Sami
    Jiang, Hua
    Kauppinen, Esko I.
    Koskinen, Jari
    Laurila, Tomi
    ANALYTICAL CHEMISTRY, 2020, 92 (12) : 8218 - 8227
  • [2] Introduction of an electrochemical point-of-care assay for quantitative determination of paracetamol in finger-prick capillary whole blood samples
    Kujala, Johanna
    Wester, Niklas
    Lohela, Terhi J.
    Kurkela, Mika
    Backman, Janne T.
    Mikladal, Bjorn
    Laurila, Tomi
    Koskinen, Jari
    Lilius, Tuomas O.
    Kalso, Eija A.
    BRITISH JOURNAL OF CLINICAL PHARMACOLOGY, 2023, 89 (09) : 2933 - 2938
  • [3] Polytyramine Film-Coated Single-Walled Carbon Nanotube Electrochemical Chemosensor with Molecularly Imprinted Polymer Nanoparticles for Duloxetine-Selective Determination in Human Plasma
    Jyoti
    Zolek, Teresa
    Maciejewska, Dorota
    Gilant, Edyta
    Gniazdowska, Elzbieta
    Kutner, Andrzej
    Noworyta, Krzysztof R.
    Kutner, Wlodzimierz
    ACS SENSORS, 2022, 7 (07) : 1829 - 1836