Modified Acetabuloplasty using Bioresorbable Screws and Lyophilised Allogenic Bone

被引:3
|
作者
Funk, J. F. [1 ]
Perka, C. [1 ]
Pruss, A. [2 ]
Meiss, A. L.
Placzek, R. [1 ]
机构
[1] Orthopad Univ Klin Charite, Centrum Muskuloskeletale Chirurg, D-10117 Berlin, Germany
[2] Charite, Gewebebank, Inst Transfus Med, D-13353 Berlin, Germany
来源
ZEITSCHRIFT FUR ORTHOPADIE UND UNFALLCHIRURGIE | 2008年 / 146卷 / 06期
关键词
acetabuloplasty; allogenic bone graft; bioresorbable implants; congenital hip dysplasia; Perthes disease;
D O I
10.1055/s-2008-1038797
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Aim: Various pericapsular procedures are available to surgically improve the acetabular coverage of the femoral head prior to closure of the triradiate cartilage. In this study the acetabuloplasty with the modification according to Westin (Pember-Sal) was applied. Indications for surgery were congenital hip dysplasia or luxation as well as Perthes' disease. To date, the standard procedures for acetabuloplasty include the transplantation of an autologous iliac crest bone graft and the fixation with K-wires. The aim of this study was to investigate if a modification of the operative procedure with the use of resorbable screws and allogenic bone transplants can minimise the operative trauma, avoid a second procedure, and permit MRI follow-ups without increasing the risk of the operation. Method: 15 patients with a mean age of 6.7 years were included in this case series and treated with a modified acetabuloplasty for the indication hip dysplasia or Perthes' disease. The modification of the standard procedure included the transplantation of allogenic bone wedges customised from lyophilised femoral grafts. The fixation was performed with bioresorbable polylactide screws. Clinical and radiographical follow-ups were conducted. Results: Procedure-related complications occurred neither in the intra- nor the postoperative period. The allogenic bone graft was remodelled successively as seen on radiographic controls. Dislocations of the bone wedges were not detectable. Subsiding of the allograft did not occur to a noticeable extent as the acetabular index showed no increase during follow-up. Conclusion: This study presents a gentle method of acetabuloplasty which avoids iliac crest bone harvesting with its known complications as well as a second procedure under anaesthesia for the removal of implants.
引用
收藏
页码:720 / 724
页数:5
相关论文
共 50 条
  • [1] BIORESORBABLE SCREWS FOR FACIAL BONE RECONSTRUCTION - A PILOT-STUDY IN RABBITS
    KELLMAN, RM
    HUCKINS, SC
    KING, J
    HUMPHREY, D
    MARENTETTE, L
    OSBORN, DC
    LARYNGOSCOPE, 1994, 104 (05): : 556 - 561
  • [2] In Vivo Study of Organ and Tissue Stability According to the Types of Bioresorbable Bone Screws
    Kwon, Tae-Young
    Lee, Geum-Hwa
    Lee, Hyuk
    Lee, Kwang-Bok
    MATERIALS, 2024, 17 (22)
  • [3] Disc-repositioning surgery of the temporomandibular joint using bioresorbable screws
    Sembronio, S.
    Robiony, M.
    Politi, M.
    INTERNATIONAL JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2006, 35 (12) : 1149 - 1152
  • [4] Healing of bone defects using bioresorbable and non bioresorbable membranes.
    Imbronito, AV
    Todescan, JH
    Arana-Chaves, VE
    Carvalho, CV
    Tristào, GC
    JOURNAL OF DENTAL RESEARCH, 1999, 78 (05) : 989 - 989
  • [5] Anterior cruciate ligament reconstruction using patellar tendon autograft and bioresorbable interference screws
    Hofmann G.O.
    Wagner F.D.
    Beickert R.
    Gonschorek O.
    Bühren V.
    European Journal of Trauma, 2001, 27 (5): : 241 - 249
  • [6] Osteochondral graft fixation using a bioresorbable bone cement
    Changoor, Adele
    Hurtig, Mark B.
    Runciman, R. John
    JOURNAL OF BIOMECHANICS, 2006, 39 (15) : 2887 - 2892
  • [7] Mechanical Performance of Metallic Bone Screws Evaluated Using Bone Models
    Okazaki, Yoshimitsu
    Hayakawa, Emiko
    Tanahashi, Kazumasa
    Mori, Jun
    MATERIALS, 2020, 13 (21) : 1 - 21
  • [8] Die Behandlung von Syndesmosenrupturen mit resorbierbaren SchraubenFixation of Syndesmotic Disruption Using Bioresorbable Screws
    Maarten van der Elst
    Erwin Coster
    Maarten Dekker
    Operative Orthopädie und Traumatologie, 2007, 19 (3) : 294 - 304
  • [9] The Application of an Allogenic Bone Screw for Stabilization of a Modified Chevron Osteotomy: A Prospective Analysis
    Huber, Thorsten
    Hofstaetter, Stefan G.
    Fiala, Rainer
    Hartenbach, Florian
    Breuer, Robert
    Rath, Bjoern
    JOURNAL OF CLINICAL MEDICINE, 2022, 11 (05)
  • [10] Bone augmentation using bioresorbable mesh domes containing bone graft granules
    Yanagisawa, Toshiki
    Hayashi, Koichiro
    Ishikawa, Kunio
    JOURNAL OF MATERIALS SCIENCE-MATERIALS IN MEDICINE, 2024, 35 (01)