Neutron and gamma ray doses from a 252Cf brachytherapy source in a water phantom

被引:6
|
作者
Al-Saihati, Ibahim [1 ]
Naqvi, A. A. [2 ]
机构
[1] King Fahd Univ Petr & Minerals, Dept Elect Engn, Dhahran 31261, Saudi Arabia
[2] King Fahd Univ Petr & Minerals, Dept Phys, Dhahran 31261, Saudi Arabia
关键词
Brachytherapy; Californium-252; Monte Carlo Simulation; Neutron dose; Gamma dose;
D O I
10.1007/s10967-012-2172-5
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Axial and radial doses of Neutrons and gamma rays from an Isotron Cf-252 Brachytherapy source were calculated in a Water phantom using Maienshein's prompt fission gamma rays data and Maxwellian neutron energy spectrum. It was observed that neutron dose due to the source casing thickness does not contribute significantly to the total dose. Further the calculated secondary gamma ray dose rate is very small compared to the calculated primary gamma dose rate. Neutron and secondary gamma ray dose calculated in this study agree with the published data. Results of this study will be presented here.
引用
收藏
页码:963 / 966
页数:4
相关论文
共 50 条
  • [1] Neutron and gamma ray doses from a 252Cf brachytherapy source in a water phantom
    Ibahim Al-Saihati
    A. A. Naqvi
    Journal of Radioanalytical and Nuclear Chemistry, 2013, 296 : 963 - 966
  • [2] Neutron dosimetry for a general 252Cf brachytherapy source
    Rivard, MJ
    MEDICAL PHYSICS, 2000, 27 (12) : 2803 - 2815
  • [3] TOF spectrum measurement of 252Cf source fission neutron and gamma ray
    College of Communication Engineering, Chongqing University, Chongqing 400044, China
    不详
    Qiangjiguang Yu Lizishu, 2009, 11 (1719-1723):
  • [4] GAMMA DOSE RATE NEAR A NEW 252Cf BRACHYTHERAPY SOURCE
    Fortune, Eugene C.
    Gauld, Ian C.
    Wang, C. -K. Chris
    NUCLEAR TECHNOLOGY, 2011, 175 (01) : 73 - 76
  • [5] ADVANTAGES AND APPLICATIONS OF 252CF AS A NEUTRON SOURCE
    REINIG, WC
    NUCLEAR APPLICATIONS, 1968, 5 (01): : 24 - &
  • [6] Water-extended polyester neutron shield for a 252Cf neutron source
    Vega-Carrillo, H. R.
    Manzanares-Acuna, E.
    Hernandez-Davila, V. M.
    Gallego, E.
    Lorente, A.
    Donaire, I.
    RADIATION PROTECTION DOSIMETRY, 2007, 126 (1-4) : 269 - 273
  • [7] Monte Carlo Investigation on Neutron Dosimetry Parameters of 252Cf Isotron Brachytherapy Source
    Ahmadi, Ome Leila
    Tavakoli-Anbaran, Hossein
    SAINS MALAYSIANA, 2020, 49 (03): : 693 - 701
  • [8] Resistive plate chamber neutron and gamma sensitivity measurement with a 252Cf source
    Abbrescia, M
    Altieri, S
    Baratti, V
    Barnabà, O
    Belli, G
    Bruno, G
    Colaleo, A
    DeVecchi, C
    Guida, R
    Iaselli, G
    Imbres, E
    Loddo, F
    Maggi, M
    Marangelli, B
    Musitelli, G
    Nardò, R
    Natali, S
    Nuzzo, S
    Pugliese, G
    Ranieri, A
    Ratti, S
    Riccardi, C
    Romano, F
    Torre, P
    Vicini, A
    Vitulo, P
    Volpe, F
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2003, 506 (1-2): : 101 - 109
  • [9] DESIGN DATA FOR 252CF NEUTRON SOURCE EXPERIMENTS
    NICHOLS, JP
    NUCLEAR APPLICATIONS, 1968, 4 (06): : 382 - &
  • [10] NEUTRON RADIOGRAPHY WITH 252CF
    CASON, JL
    SHAW, CB
    TRANSACTIONS OF THE AMERICAN NUCLEAR SOCIETY, 1969, 12 (02): : 464 - &