Teager-Kaiser Operator improves the accuracy of EMG onset detection independent of signal-to-noise ratio

被引:0
|
作者
Solnik, Stanislaw [1 ]
Devita, Paul [1 ]
Rider, Patrick [1 ]
Long, Benjamin [1 ]
Hortobagyi, Tibor [1 ]
机构
[1] E Carolina Univ, Biomech Lab, Greenville, NC 27858 USA
关键词
Teager-Kaiser Operator; EMG onset detection; signal conditioning;
D O I
暂无
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
A temporal analysis of electromyographic (EMG) activity has widely been used for non-invasive study of muscle activation patterns. Such an analysis requires robust methods to accurately detect EMG onset. We examined whether data conditioning, supplemented with Teager-Kaiser Energy Operator (TKEO), would improve accuracy of the EMG burst onset detection. EMG signals from vastus lateralis, collected during maximal voluntary contractions, performed by seventeen subjects (8 males, 9 females, mean age of 46 yrs), were analyzed. The error of onset detection using enhanced signal conditioning was significantly lower than that of onset detection performed on signals conditioned without the TKEO (40 +/- 99 ms vs. 229 +/- 356 ms, t-test, p = 0.023). The Pearson correlations revealed that neither accuracy after enhanced conditioning nor accuracy after standard conditioning was significantly related to signal-to-noise ratio (SNR) (r = -0.05, p = 0.8 and r = -0.19, p = 0.46, respectively). It is concluded that conditioning of the EMG signals with TKEO significantly improved the accuracy of the threshold-based onset detection methods, regardless of SNR magnitude.
引用
收藏
页码:65 / 68
页数:4
相关论文
共 50 条
  • [1] Teager-Kaiser energy operator signal conditioning improves EMG onset detection
    Solnik, Stanislaw
    Rider, Patrick
    Steinweg, Ken
    DeVita, Paul
    Hortobagyi, Tibor
    EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY, 2010, 110 (03) : 489 - 498
  • [2] Teager–Kaiser energy operator signal conditioning improves EMG onset detection
    Stanislaw Solnik
    Patrick Rider
    Ken Steinweg
    Paul DeVita
    Tibor Hortobágyi
    European Journal of Applied Physiology, 2010, 110 : 489 - 498
  • [3] EMG Onset Detection Based on Teager-Kaiser Energy Operator and Morphological Close Operation
    Yang, Dapeng
    Huang, Qi
    Yang, Wei
    Liu, Hong
    INTELLIGENT ROBOTICS AND APPLICATIONS, ICIRA 2015, PT I, 2015, 9244 : 257 - 268
  • [4] Teager-Kaiser energy operation of surface EMG improves muscle activity onset detection
    Li, Xiaoyan
    Zhou, Ping
    Aruin, Alexander S.
    ANNALS OF BIOMEDICAL ENGINEERING, 2007, 35 (09) : 1532 - 1538
  • [5] Improving EMG Signal Change Point Detection for Low SNR by Using Extended Teager-Kaiser Energy Operator
    Tigrini, Andrea
    Mengarelli, Alessandro
    Cardarelli, Stefano
    Fioretti, Sandro
    Verdini, Federica
    IEEE TRANSACTIONS ON MEDICAL ROBOTICS AND BIONICS, 2020, 2 (04): : 661 - 669
  • [6] Muscle activity onset time detection using Teager-Kaiser energy operator
    Li, Xiaoyan
    Aruin, Alexander S.
    2005 27TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-7, 2005, : 7549 - 7552
  • [7] An Acquisition Scheme for Aperiodic DSSS Signal Based on Teager-Kaiser Operator
    Tian Tian
    An Jianping
    Wang Aihua
    2010 6TH INTERNATIONAL CONFERENCE ON WIRELESS COMMUNICATIONS NETWORKING AND MOBILE COMPUTING (WICOM), 2010,
  • [8] Improve the accuracy of TDOA measurement using the Teager-Kaiser Energy operator
    Kandia, Varvara
    Stylianou, Yannis
    Dutoit, Thierry
    PASSIVE '08: 2008 NEW TRENDS FOR ENVIRONMENTAL MONITORING USING PASSIVE SYSTEMS, 2008, : 85 - +
  • [9] Wideband frequency domain detection using Teager-Kaiser energy operator
    Gautier, Matthieu
    Berg, Vincent
    Noguet, Dominique
    2012 7TH INTERNATIONAL ICST CONFERENCE ON COGNITIVE RADIO ORIENTED WIRELESS NETWORKS AND COMMUNICATIONS (CROWNCOM), 2012, : 332 - 337
  • [10] Fault detection for PV systems using Teager-Kaiser energy operator
    Khoshnami, A.
    Sadeghkhani, I.
    ELECTRONICS LETTERS, 2018, 54 (23) : 1342 - 1343