Integration of functional brain information into stereotactic irradiation treatment planning using magnetoencephalography and magnetic resonance axonography
被引:26
|
作者:
Aoyama, H
论文数: 0引用数: 0
h-index: 0
机构:Hokkaido Univ, Grad Sch Med, Dept Radiol, Kita Ku, Sapporo, Hokkaido 0608638, Japan
Aoyama, H
Kamada, K
论文数: 0引用数: 0
h-index: 0
机构:Hokkaido Univ, Grad Sch Med, Dept Radiol, Kita Ku, Sapporo, Hokkaido 0608638, Japan
Kamada, K
Shirato, H
论文数: 0引用数: 0
h-index: 0
机构:Hokkaido Univ, Grad Sch Med, Dept Radiol, Kita Ku, Sapporo, Hokkaido 0608638, Japan
Shirato, H
Takeuchi, F
论文数: 0引用数: 0
h-index: 0
机构:Hokkaido Univ, Grad Sch Med, Dept Radiol, Kita Ku, Sapporo, Hokkaido 0608638, Japan
Takeuchi, F
Kuriki, S
论文数: 0引用数: 0
h-index: 0
机构:Hokkaido Univ, Grad Sch Med, Dept Radiol, Kita Ku, Sapporo, Hokkaido 0608638, Japan
Kuriki, S
Iwasaki, Y
论文数: 0引用数: 0
h-index: 0
机构:Hokkaido Univ, Grad Sch Med, Dept Radiol, Kita Ku, Sapporo, Hokkaido 0608638, Japan
Iwasaki, Y
Miyasaka, K
论文数: 0引用数: 0
h-index: 0
机构:Hokkaido Univ, Grad Sch Med, Dept Radiol, Kita Ku, Sapporo, Hokkaido 0608638, Japan
Miyasaka, K
机构:
[1] Hokkaido Univ, Grad Sch Med, Dept Radiol, Kita Ku, Sapporo, Hokkaido 0608638, Japan
[2] Hokkaido Univ, Grad Sch Med, Dept Neurosurg, Sapporo, Hokkaido 0608638, Japan
[3] Hokkaido Univ, Res Inst Appl Elect, Sapporo, Hokkaido 0608638, Japan
Purpose: To minimize the risk of neurologic deficit after stereotactic irradiation, functional brain information was integrated into treatment planning. Methods and Materials: Twenty-one magnetoencephalography and six magnetic resonance axonographic images were made in 20 patients to evaluate the sensorimotor cortex (n = 15 patients, including the corticospinal tract in 6), visual cortex (n = 4), and Wernicke's area (n = 2). One radiation oncologist was asked to formulate a treatment plan first without the functional images and then to modify the plan after seeing them. The pre- and postmodification values were compared for the volume of the functional area receiving greater than or equal to15 Gy and the volume of the planning target volume receiving greater than or equal to80% of the prescribed dose. Results: Of the 21 plans, 15 (71%) were modified after seeing the functional images. After modification, the volume receiving greater than or equal to15 Gy was significantly reduced compared with the values before modification in those 15 sets of plans (p = 0.03). No statistically significant difference was found in the volume of the planning target volume receiving greater than or equal to80% of the prescribed dose (p = 0.99). During follow-up, radiation-induced necrosis at the corticospinal tract caused a minor motor deficit in 1 patient for whom magnetic resonance axonography was not available in the treatment planning. No radiation-induced functional deficit was observed in the other patients. Conclusion: Integration of magnetoencephalography and magnetic resonance axonography in treatment planning has the potential to reduce the risk of radiation-induced functional dysfunction without deterioration of the dose distribution in the target volume. (C) 2004 Elsevier Inc.
机构:
NYU, Langone Med Ctr, Dept Radiat Oncol, New York, NY 10016 USANYU, Langone Med Ctr, Dept Radiat Oncol, New York, NY 10016 USA
Chang, Jenghwa
Thakur, Sunitha B.
论文数: 0引用数: 0
h-index: 0
机构:
Mem Sloan Kettering Canc Ctr, Dept Med Phys, New York, NY 10065 USANYU, Langone Med Ctr, Dept Radiat Oncol, New York, NY 10016 USA
Thakur, Sunitha B.
Huang, Wei
论文数: 0引用数: 0
h-index: 0
机构:
Mem Sloan Kettering Canc Ctr, Dept Med Phys, New York, NY 10065 USA
Mem Sloan Kettering Canc Ctr, Dept Radiol, New York, NY 10065 USANYU, Langone Med Ctr, Dept Radiat Oncol, New York, NY 10016 USA
Huang, Wei
Narayana, Ashwatha
论文数: 0引用数: 0
h-index: 0
机构:
NYU, Langone Med Ctr, Dept Radiat Oncol, New York, NY 10016 USANYU, Langone Med Ctr, Dept Radiat Oncol, New York, NY 10016 USA