Influence of the Position of the Collimator of an X-Ray Diffractometer on the Value of Measured Residual Stresses

被引:3
|
作者
Trofimov, V. N. [1 ]
Shiryaev, A. A. [1 ]
Karmanov, V. V. [1 ]
机构
[1] Perm Natl Res Polytech Univ, 29 Komsomolskiy Ave, Perm 614990, Russia
关键词
D O I
10.1063/1.5084535
中图分类号
O3 [力学];
学科分类号
08 ; 0801 ;
摘要
In mechanical engineering, in particular, in the manufacture of parts for gas turbine installations and gas turbine engines with variable geometry compressor and turbine blades, holes in disks, etc. and complex shapes, it is necessary to control the level of residual stresses. When using the X-ray diffractometry method, it is necessary to ensure the position of the diffractometer collimator along the normal to the surface under investigation. For the specified parts, this condition is not always feasible. In this paper, the effect of the position of an X-ray diffractometer collimator relative to the measurement surface on the value of the measured residual stresses is estimated. Flat samples from steel 09G2S and alloy VZhL14 are used. The position of the collimator relative to the plane of the sample is determined by an angle alpha that is varied from 0 degrees to 30 degrees in steps of 5 degrees. As a result of the measurements, the values of the measured residual stresses are compared with their value at 0 degrees and the limiting angles are found, above which there is a substantial distortion of the measurement results.
引用
收藏
页数:4
相关论文
共 50 条
  • [1] SYSTEM FOR AUTOMATIC OPENING OF COLLIMATOR OF X-RAY DIFFRACTOMETER
    LOISEL, M
    BULLETIN DE LA SOCIETE FRANCAISE DE CERAMIQUE, 1971, (90): : 55 - &
  • [2] COLLIMATOR CORRECTIONS TO MEASURED DIFFUSE X-RAY BACKGROUND
    DUMAS, A
    HORSTMAN, H
    HORSTMAN.E
    ASTROPHYSICS AND SPACE SCIENCE, 1972, 19 (02) : 495 - 500
  • [3] THE PRADON MOBILE AUTOMATIC X-RAY DIFFRACTOMETER FOR DETERMINING STRESSES
    MYASNIKOV, YG
    BOLSHAKOV, PP
    LIFSHITS, VA
    TUTELMAN, NS
    CHEZHIN, FN
    LAKTIONOV, GA
    TKACHEV, VI
    INDUSTRIAL LABORATORY, 1986, 52 (02): : 151 - 154
  • [4] Residual Stresses in Polycrystalline Iron Alloys Measured by X-ray Diffraction and Related Microstructure
    Suzuki, Shigeru
    Sato, Shigeo
    IMAShuku, Susumu
    Sato, Hiroyuki
    Tanaka, Shun-Ichiro
    Tetsu-To-Hagane/Journal of the Iron and Steel Institute of Japan, 2024, 110 (12): : 900 - 911
  • [5] EFFECT OF ROUGHNESS ON RESIDUAL STRESSES MEASURED BY X-RAY DIFFRACTION USING CONVENTIONAL ψ/Ω GEOMETRIES
    Kuznetsov, Alexei
    Franca, Camila
    Maru, Marcia
    Silva, Rui
    Hirsch, Thomas
    Achete, Carlos
    IRF2016: 5TH INTERNATIONAL CONFERENCE INTEGRITY-RELIABILITY-FAILURE, 2016, : 733 - 734
  • [6] AN X-RAY COLLIMATOR
    LEIKIN, VN
    MINGAZIN, TA
    ZELENOV, VI
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES, 1981, 24 (03) : 788 - 789
  • [7] DIFFRACTOMETER MISALIGNMENT ERRORS IN X-RAY RESIDUAL-STRESS MEASUREMENTS
    JO, J
    HENDRICKS, RW
    JOURNAL OF APPLIED CRYSTALLOGRAPHY, 1991, 24 : 878 - 887
  • [8] ADJUSTING AN X-RAY DIFFRACTOMETER
    BONDARS, BY
    INDUSTRIAL LABORATORY, 1989, 55 (10): : 1151 - 1152
  • [9] X-Ray Determination of Residual Stresses with the Aid of a Position-Sensitive Proportional Detector.
    Saint-Etienne, A.
    1976, 59 (318-319): : 39 - 41
  • [10] NOVEL X-RAY DIFFRACTOMETER POSITION-SENSITIVE DETECTOR SYSTEM
    FRAASS, BA
    GRANFORS, PR
    HILLEKE, RO
    SIMMONS, RO
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1984, 55 (09): : 1455 - 1460