Reliability of assessing trunk motor control using position and force tracking and stabilization tasks

被引:15
|
作者
Reeves, N. Peter [1 ,2 ]
Popovich, John M., Jr. [1 ,2 ]
Priess, M. Cody [1 ,3 ]
Cholewicki, Jacek [1 ,2 ]
Choi, Jongeun [1 ,3 ,4 ]
Radcliffe, Clark J. [1 ,3 ]
机构
[1] Michigan State Univ, Ctr Orthoped Res, E Lansing, MI 48824 USA
[2] Michigan State Univ, Dept Osteopath Surg Specialties, E Lansing, MI 48824 USA
[3] Michigan State Univ, Dept Mech Engn, E Lansing, MI 48824 USA
[4] Michigan State Univ, Dept Elect & Comp Engn, E Lansing, MI 48824 USA
基金
美国国家卫生研究院;
关键词
Trunk position control; Trunk force control; H-2; norm; Disturbance rejection; Systems approach; LOW-BACK-PAIN; BETWEEN-DAY RELIABILITY; POSTURAL CONTROL; SENSORIMOTOR INTEGRATION; LUMBAR SPINE; REFLEX; STABILITY; INDIVIDUALS; RESPONSES; FLEXION;
D O I
10.1016/j.jbiomech.2013.10.018
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
System-based methods have been applied to assess trunk motor control in people with and without back pain, although the reliability of these methods has yet to be established. Therefore, the goal of this study was to quantify within- and between-day reliability using systems-based methods involving position and force tracking and stabilization tasks. Ten healthy subjects performed six tasks, involving tracking and stabilizing of trunk angular position in the sagittal plane, and trunk flexion and extension force. Tracking tasks involved following a one-dimensional, time-varying input signal displayed on a screen by changing trunk position (position tracking) or trunk force (force tracking). Stabilization tasks involved maintaining a constant trunk position (position stabilization) or constant trunk force (force stabilization) while a sagittal plane disturbance input was applied to the pelvis using a robotic platform. Time and frequency domain assessments of error (root mean square and H-2 norm, respectively) were computed for each task on two separate days. Intra-class correlation coefficients (ICC) for error and coefficients of multiple correlations (CMC) for frequency response curves were used to quantify reliability of each task. Reliability for all tasks was excellent (between-day ICC >= 0.8 and CMC > 0.75, within-day CMC > 0.85). Therefore, position and force control tasks used to assess trunk motor control can be deemed reliable. (C) 2013 Elsevier Ltd. All rights reserved.
引用
收藏
页码:44 / 49
页数:6
相关论文
共 50 条
  • [1] Trunk stabilization estimated using pseudorandom force perturbations, a reliability study
    Griffioen, M.
    Maaswinkel, E.
    Zuurmond, W. W. A.
    van Dieen, J. H.
    Perez, R. S. G. M.
    JOURNAL OF BIOMECHANICS, 2016, 49 (02) : 244 - 251
  • [2] Sensory Weighting of Force and Position Feedback in Human Motor Control Tasks
    Mugge, Winfred
    Schuurmans, Jasper
    Schouten, Alfred C.
    van der Helm, Frans C. T.
    JOURNAL OF NEUROSCIENCE, 2009, 29 (17): : 5476 - 5482
  • [3] Assessing delay and lag in sagittal trunk control using a tracking task
    Reeves, N. Peter
    Luis, Abraham
    Chan, Elizabeth C.
    Sal y Rosas, Victor G.
    Tanaka, Martin L.
    JOURNAL OF BIOMECHANICS, 2018, 73 : 33 - 39
  • [4] Motor unit firing patterns on increasing force during force and position tasks
    Kunugi, Shun
    Holobar, Ales
    Kodera, Tsutomu
    Toyoda, Heishiro
    Watanabe, Kohei
    JOURNAL OF NEUROPHYSIOLOGY, 2021, 126 (05) : 1653 - 1659
  • [5] ROBUST AND ADAPTIVE POSITION FORCE STABILIZATION OF ROBOTIC MANIPULATORS IN CONTACT TASKS
    EKALO, Y
    VUKOBRATOVIC, M
    ROBOTICA, 1993, 11 : 373 - 386
  • [6] Position control and explicit force control for accurate grinding tasks of a manipulator using constraint dynamics
    Minami, M
    Ikeda, T
    PROCEEDINGS OF THE 5TH ASIA-PACIFIC CONFERENCE ON CONTROL & MEASUREMENT, 2002, : 174 - 179
  • [7] Hybrid-mode Impedance Control for Position/force Tracking in Motor-system Rehabilitation
    Kim, Youngwoo
    INTERNATIONAL JOURNAL OF ADVANCED ROBOTIC SYSTEMS, 2015, 12
  • [8] ASSESSING MOTOR IMPAIRMENT OF THE TRUNK IN PATIENTS WITH TRAUMATIC BRAIN INJURY: RELIABILITY AND VALIDITY OF THE TRUNK IMPAIRMENT SCALE
    Verheyden, G.
    Hughes, J.
    Jelsma, J.
    Nieuwboer, A.
    De Weerdt, W.
    SOUTH AFRICAN JOURNAL OF PHYSIOTHERAPY, 2006, 62 (02) : 23 - 27
  • [9] Motor control strategies during unpredictable force control tasks in humans
    Almotairy, Nabeel
    Kumar, Abhishek
    Grigoriadis, Anastasios
    JOURNAL OF ORAL REHABILITATION, 2020, 47 (10) : 1222 - 1232
  • [10] TARGET TRACKING ROBOTIC MANIPULATION THEORIES APPLIED TO FORCE/POSITION CONTROL IN PEG-IN-HOLE ASSEMBLY TASKS
    Giblin, D. J.
    Liu, Y.
    Kazerounian, K.
    INTERNATIONAL JOURNAL OF ROBOTICS & AUTOMATION, 2008, 23 (01): : 49 - 55