Non-Rigid Event-by-Event Continuous Respiratory Motion Compensated List-Mode Reconstruction for PET

被引:27
|
作者
Chan, Chung [1 ,2 ]
Onofrey, John [1 ]
Jian, Yiqiang [1 ,3 ]
Germino, Mary [1 ,4 ]
Papademetris, Xenophon [1 ]
Carson, Richard E. [5 ]
Liu, Chi [1 ]
机构
[1] Yale Univ, Dept Radiol & Biomed Imaging, New Haven, CT 06520 USA
[2] Toshiba Med Res Inst USA Inc, Vernon Hills, IL 60061 USA
[3] GE Healthcare, Waukesha, WI 53188 USA
[4] Regeneron Pharmaceut Inc, Tarrytown, NY 10591 USA
[5] Yale Univ, Dept Radiol & Biomed Imaging, Yale PET Ctr, New Haven, CT 06520 USA
关键词
Event-by-event motion correction; image reconstruction; list-mode reconstruction; non-rigid motion correction; positron emission tomography (PET); IMAGE-RECONSTRUCTION; IMPACT; QUANTIFICATION; IMPLEMENTATION; GATE;
D O I
10.1109/TMI.2017.2761756
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
Respiratory motion during positron emission tomography (PET)/computed tomography (CT) imaging can cause significant image blurring and underestimation of tracer concentration for both static and dynamic studies. In this paper, with the aim to eliminate both intra-cycle and inter-cycle motions, and apply to dynamic imaging, we developed a non-rigid event-by-event (NR-EBE) respiratory motion-compensated list-mode reconstruction algorithm. The proposed method consists of two components: the first component estimates a continuous non-rigid motion field of the internal organs using the internal-external motion correlation. This continuous motion field is then incorporated into the second component, non-rigid MOLAR (NR-MOLAR) reconstruction algorithm to deform the system matrix to the reference location where the attenuation CT is acquired. The point spread function (PSF) and time-of-flight (TOF) kernels in NR-MOLAR are incorporated in the system matrix calculation, and therefore are also deformed according to motion. We first validated NR-MOLAR using a XCAT phantom with a simulated respiratory motion. NR-EBE motion-compensated image reconstruction using both the components was then validated on three human studies injected with F-18-FPDTBZ and one with F-18-fluorodeoxyglucose (FDG) tracers. The human results were compared with conventional non-rigid motion correction using discrete motion field (NR-discrete, one motion field per gate) and a previously proposed rigid EBE motion-compensated image reconstruction (R-EBE) that was designed to correct for rigid motion on a target lesion/organ. The XCAT results demonstrated that NR-MOLAR incorporating both PSF and TOF kernels effectively corrected for non-rigid motion. The F-18-FPDTBZ studies showed that NR-EBE out-performed NR-Discrete, and yielded comparable results with R-EBE on target organs while yielding superior image quality in other regions. The FDG study showed that NR-EBE clearly improved the visibility of multiple moving lesions in the liver where some of them could not be discerned in other reconstructions, in addition to improving quantification. These results show that NR-EBE motion-compensated image reconstruction appears to be a promising tool for lesion detection and quantification when imaging thoracic and abdominal regions using PET.
引用
收藏
页码:504 / 515
页数:12
相关论文
共 50 条
  • [1] Whole-body continuous-bed-motion PET list-mode reconstruction with non-rigid event-by-event respiratory motion correction
    Lu, Yihuan
    Fontaine, Kathryn
    Gallezot, Jean-Dominique
    Mulnix, Tim
    Panin, Vladimir
    Jones, Judson
    Casey, Michael
    Carson, Richard
    Liu, Chi
    JOURNAL OF NUCLEAR MEDICINE, 2019, 60
  • [2] Event-by-Event Image Reconstruction From List-Mode PET Data
    Schretter, Colas
    IEEE TRANSACTIONS ON IMAGE PROCESSING, 2009, 18 (01) : 117 - 124
  • [3] Event-by-event PET image reconstruction using list-mode origin ensembles algorithm
    Andreyev, Andriy
    MEDICAL IMAGING 2016: PHYSICS OF MEDICAL IMAGING, 2016, 9783
  • [4] List-mode reconstruction for the Biograph mCT with physics modeling and event-by-event motion correction
    Jin, Xiao
    Chan, Chung
    Mulnix, Tim
    Panin, Vladimir
    Casey, Michael E.
    Liu, Chi
    Carson, Richard E.
    PHYSICS IN MEDICINE AND BIOLOGY, 2013, 58 (16): : 5567 - 5591
  • [5] Data-driven event-by-event respiratory motion correction using TOF PET list-mode centroid of distribution
    Ren, Silin
    Jin, Xiao
    Chan, Chung
    Jian, Yiqiang
    Mulnix, Tim
    Liu, Chi
    Carson, Richard E.
    PHYSICS IN MEDICINE AND BIOLOGY, 2017, 62 (12): : 4741 - 4755
  • [6] List-mode Reconstruction for the Biograph mCT with Probabilistic Line-of-Response Positioning and Event-by-Event Motion Correction
    Jin, Xiao
    Chan, Chung
    Mulnix, Tim
    Liu, Chi
    Carson, Richard E.
    2012 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE RECORD (NSS/MIC), 2012, : 3682 - 3687
  • [7] Event-by-Event Continuous Respiratory Motion Correction for Dynamic PET Imaging
    Yu, Yunhan
    Chan, Chung
    Ma, Tianyu
    Liu, Yaqiang
    Gallezot, Jean-Dominique
    Naganawa, Mika
    Kelada, Olivia J.
    Germino, Mary
    Sinusas, Albert J.
    Carson, Richard E.
    Liu, Chi
    JOURNAL OF NUCLEAR MEDICINE, 2016, 57 (07) : 1084 - 1090
  • [8] Event-by-event non-rigid data-driven PET respiratory motion correction methods: comparison of principal component analysis and centroid of distribution
    Ren, Silin
    Lu, Yihuan
    Bertolli, Ottavia
    Thielemans, Kris
    Carson, Richard E.
    PHYSICS IN MEDICINE AND BIOLOGY, 2019, 64 (16):
  • [9] Data-driven voluntary body motion detection and non-rigid event-by-event correction for static and dynamic PET
    Lu, Yihuan
    Gallezot, Jean-Dominique
    Naganawa, Mika
    Ren, Silin
    Fontaine, Kathryn
    Wu, Jing
    Onofrey, John A.
    Toyonaga, Takuya
    Boutagy, Nabil
    Mulnix, Tim
    Panini, Vladimir Y.
    Casey, Michael E.
    Carson, Richard E.
    Liu, Chi
    PHYSICS IN MEDICINE AND BIOLOGY, 2019, 64 (06):
  • [10] List-mode-based reconstruction for respiratory motion correction in PET using non-rigid body transformations
    Lamare, F.
    Carbayo, M. J. Ledesma
    Cresson, T.
    Kontaxakis, G.
    Santos, A.
    Le Rest, C. Cheze
    Reader, A. J.
    Visvikis, D.
    PHYSICS IN MEDICINE AND BIOLOGY, 2007, 52 (17): : 5187 - 5204