Computational Investigation of Wind Loads on Tilted Roof-Mounted Solar Array

被引:1
|
作者
Tu, Zhibin [1 ]
Zheng, Gensheng [2 ]
Yao, Jianfeng [1 ]
Shen, Guohui [3 ]
Lou, Wenjuan [3 ]
机构
[1] Zhejiang Univ Water Resources & Elect Power, Coll Civil Engn & Architecture, Hangzhou 310018, Peoples R China
[2] Anhui Jianzhu Univ, Coll Civil Engn, Hefei 230601, Peoples R China
[3] Zhejiang Univ, Coll Civil Engn & Architecture, Hangzhou 310058, Peoples R China
关键词
solar array; SST k - w turbulence model; flow field; shape factor; moment coefficient; NUMERICAL-SIMULATION; PANELS; BUILDINGS;
D O I
10.3390/su142315653
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
A detailed computational investigation of the wind field around tilted solar modules mounted on a large building roof has been undertaken, utilizing the Reynolds-Averaged Navier-Stokesv (RANS) approach supplied with the SST k - omega turbulence model. The study investigated the flow field for various tilt angle of modules at normal wind directions relative to the wall. Then the shape factors and moment coefficients of modules were explored. The results show that the recirculation vortex generated by the building edge is disintegrated to smaller local vortices. With the increasing of the tilt angle, an increasing number of local vortices emerged at the leading rows, leading to a relatively large wind pressure and shape factor at the corner of the array. In most tilt angles at 0 & DEG; and 180 & DEG; wind direction the shape factors are negative. However, for the 40 & DEG; and 55 & DEG; tilt angles at 180 & DEG; wind direction, the shape factors on the lower surfaces are positive, due to the dominating of approaching flow rather than the local vortices. The array is divided into six zones based on the distribution of shape factors. As the shape factors on upper and lower are similar, the shape factors in most zones for tilt angles from 5 & DEG; to 55 & DEG; are quite small. However, shape factors in the leading row for 30 & DEG;, 40 & DEG; and 55 & DEG; are relatively large. This indicates that the shading effect of front rows can significantly reduce the shape factors of the rear rows. Compared to the values calculated by Chinese, American and Japanese standards, the shape factors by simulation are quite small. The moment induced by nonuniform wind pressure, which is often ignored in the literature and standards, is quite large at the leading zones, with a maximum of 0.28 for 55 & DEG; tilt angle. Ignoring the wind induced moment on the leading zones may make the wind resistance design of the solar module support structure unsafe.
引用
收藏
页数:17
相关论文
共 50 条
  • [1] Aerodynamic mechanisms for wind loads on tilted, roof-mounted, solar arrays
    Kopp, Gregory A.
    Farquhar, Steve
    Morrison, Murray J.
    JOURNAL OF WIND ENGINEERING AND INDUSTRIAL AERODYNAMICS, 2012, 111 : 40 - 52
  • [2] Experimental Investigation of Wind Loads on Roof-Mounted Solar Arrays
    Yao, Jianfeng
    Tu, Zhibin
    Wang, Dong
    Shen, Guohui
    Lou, Wenjuan
    SUSTAINABILITY, 2022, 14 (14)
  • [3] NUMERICAL STUDY OF WIND LOADS ON RESIDENTIAL ROOF-MOUNTED SOLAR PHOTOVOLTAIC ARRAYS
    Giorges, Aklilu T. G.
    Amador, Guillermo J.
    Goodman, Joseph
    ASME INTERNATIONAL MECHANICAL ENGINEERING CONGRESS AND EXPOSITION, 2014, VOL 6B, 2015,
  • [4] Experimental Investigation of the Parapet Effect on the Wind Load of Roof-Mounted Solar Arrays
    Yao, Jianfeng
    Tu, Zhibin
    Wang, Dong
    Shen, Guohui
    Yu, Shice
    Lou, Wenjuan
    SUSTAINABILITY, 2023, 15 (06)
  • [5] Investigation of wind loading characteristics of roof-mounted solar panels on tall buildings
    Peng, H. Y.
    Song, S. S.
    Liu, H. J.
    Dai, S. F.
    Zhang, F. L.
    SUSTAINABLE ENERGY TECHNOLOGIES AND ASSESSMENTS, 2022, 54
  • [6] Use of the Wind Tunnel Test Method for Obtaining Design Wind Loads on Roof-Mounted Solar Arrays
    Kopp, Gregory A.
    Banks, David
    JOURNAL OF STRUCTURAL ENGINEERING, 2013, 139 (02) : 284 - 287
  • [7] Wind loads on roof-mounted isolated solar panels of tall buildings through wind tunnel testing
    Dai, S. F.
    Liu, H. J.
    Yang, J. H.
    Peng, H. Y.
    SOLAR ENERGY, 2022, 231 : 607 - 622
  • [8] Numerical investigation of installation and environmental parameters on soiling of roof-mounted solar photovoltaic array
    Chiteka, Kudzanayi
    Sridhara, S. N.
    Arora, Rajesh
    COGENT ENGINEERING, 2019, 6 (01):
  • [9] THE APPLICATION OF COMPUTATIONAL FLUID DYNAMICS FOR INSTALLING THE ROOF-MOUNTED WIND TURBINE
    Lu, Lu
    Wang, Xiuling
    PROCEEDINGS OF THE ASME INTERNATIONAL MECHANICAL ENGINEERING CONGRESS AND EXPOSITION - 2012, VOL 7, PTS A-D, 2013, : 633 - 642
  • [10] Decade performance of a roof-mounted photovoltaic array
    Begovic, Miroslav
    Ghosh, Seema R.
    Rohatgi, Ajeet
    CONFERENCE RECORD OF THE 2006 IEEE 4TH WORLD CONFERENCE ON PHOTOVOLTAIC ENERGY CONVERSION, VOLS 1 AND 2, 2006, : 2383 - +