Measurement and Analysis of Electric Signal Transmission Using Human Body as Medium for WBAN Applications

被引:18
|
作者
Kang, Taewook [1 ]
Oh, Kwang-Il [1 ]
Hwang, Jung-Hwan [1 ]
Kim, Sungeun [1 ]
Park, Hyungil [1 ]
Lee, Jaejin [1 ]
机构
[1] Elect & Telecommun Res Inst, ICT Mat & Components Res Lab, Daejeon 34129, South Korea
关键词
Capacitive coupling; channel measurement; channel modeling; digital transmission; human body channel; human body communications; wearable device; wireless body area networks; INTRABODY COMMUNICATION CHANNEL; AREA NETWORKS; HBC CHANNEL; MODEL; INTERFERENCE; TRANSCEIVER;
D O I
10.1109/TIM.2017.2783059
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Human body communications (HBCs) realize wireless body area networks (WBANs) using the human body as a transmission channel without wired or wireless connections. While presenting various approaches for measurement and analysis of the human body channel, previous studies require additional interpretations of their results to obtain practical design parameters for a desired communication system. This paper addresses the provision of specific design guidelines based on the proposed channel measurement for capacitive coupling HBC employing digital transmission, adopted in the IEEE standards 802.15.6. for WBAN. In the experiments, customized channel-sounding signals were applied to the human body using a battery-powered device with a ground-electrode size of 27x50 mm(2). The signals received after passage through the body were measured considering 30 kinds of measurement conditions determined by the body postures and locations of the transmitter and receiver. The operating frequencies of the transmission signals were varied up to 100 MHz. This work derives the minimum required lengths of symbol-codes based on analyses of channel-measured data in terms of measurement conditions, operating frequencies, and bandwidths of a receive-filter, to achieve a maximum data rate. This was done to ensure handling of intrinsic signal errors such as those by inter-symbol-interference, and to provide more reliable bit-error-rate performance in the human body channel, depending on the transmitter structures.
引用
收藏
页码:527 / 537
页数:11
相关论文
共 50 条
  • [1] BodyRC: Exploring Interaction Modalities Using Human Body as Lossy Signal Transmission Medium
    Wang, Yuntao
    Yu, Chun
    Du, Lin
    Huang, Jin
    Shi, Yuanchun
    2014 IEEE 11TH INTL CONF ON UBIQUITOUS INTELLIGENCE AND COMPUTING AND 2014 IEEE 11TH INTL CONF ON AUTONOMIC AND TRUSTED COMPUTING AND 2014 IEEE 14TH INTL CONF ON SCALABLE COMPUTING AND COMMUNICATIONS AND ITS ASSOCIATED WORKSHOPS, 2014, : 260 - 267
  • [2] The human body characteristics as a signal transmission medium for intrabody communication
    Cho, Namjun
    Yoo, Jerald
    Song, Seong-Jun
    Lee, Jeabin
    Jeon, Seonghyun
    Yoo, Hoi-Jun
    IEEE TRANSACTIONS ON MICROWAVE THEORY AND TECHNIQUES, 2007, 55 (05) : 1080 - 1086
  • [3] Measurement and Evaluation of Electric Signal Transmission Through Human Body by Channel Modeling, System Design, and Implementation
    Kang, Taewook
    Hwang, Jung-Hwan
    Kim, Hyuk
    Kim, Sung-Eun
    Oh, Kwang-Il
    Lee, Jae-Jin
    Park, Hyung-Il
    Kim, Seong-Eun
    Oh, Wangrok
    Lee, Woojoo
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2021, 70 (70)
  • [4] Electric Field Communication using a Car Body as a Transmission Medium
    Matsui, Yoshiki
    Nezu, Kenta
    Takahashi, Naoya
    Yoshioka, Koki
    Shinagawa, Mitsuru
    Hamamura, Kohei
    Nakamura, Hiroshi
    Shimizu, Naohiro
    2019 13TH INTERNATIONAL CONFERENCE ON SENSING TECHNOLOGY (ICST), 2019,
  • [5] Experimental Evaluation of UWB Human body Transmission Model for WBAN
    Teawchim, Sanit
    Promwong, Sathaporn
    2016 13TH INTERNATIONAL CONFERENCE ON ELECTRICAL ENGINEERING/ELECTRONICS, COMPUTER, TELECOMMUNICATIONS AND INFORMATION TECHNOLOGY (ECTI-CON), 2016,
  • [6] Biomedical Signal Transmission Using Human Body Communication
    Koshiji, Fukuro
    Urushidate, Ryogo
    Koshiji, Kohji
    2017 IEEE 36TH INTERNATIONAL PERFORMANCE COMPUTING AND COMMUNICATIONS CONFERENCE (IPCCC), 2017,
  • [7] Measurement of electrode-tissue interface impedance for improvement of a transcutaneous data transmission using human body as transmission medium
    Okamoto, Eiji
    Kato, Yoshikuni
    Kikuchi, Sakiko
    Mitamura, Yoshinori
    BIO-MEDICAL MATERIALS AND ENGINEERING, 2014, 24 (04) : 1735 - 1742
  • [8] Evaluation of Human Body Characteristics for Electric Signal Transmission Based on Measured Body Impulse Response
    Kang, Taewook
    Kim, Sungeun
    Oh, Kwang-Il
    Hwang, Jung-Hwan
    Lee, Jaejin
    Park, Hyungil
    Byun, Kyungjin
    Lee, Woojoo
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2020, 69 (09) : 6399 - 6411
  • [9] Electric Field Measurement of the Living Human Body for Biomedical Applications: Phase Measurement of the Electric Field Intensity
    Hieda, Ichiro
    Nam, Ki Chang
    INTERNATIONAL JOURNAL OF ANTENNAS AND PROPAGATION, 2013, 2013
  • [10] Human Body as a Signal Transmission Medium for Body-Coupled Communication: Galvanic-Mode Models
    Aristov, Vladimir
    Elsts, Atis
    ELECTRONICS, 2023, 12 (21)