Single-Phase Auto-Reclosing Scheme Using Particle Filter and Convolutional Neural Network

被引:12
|
作者
Saad, Muhammad [1 ]
Kim, Chul-Hwan [1 ]
Munir, Nauman [2 ,3 ]
机构
[1] Sungkyunkwan Univ, Dept Elect & Comp Engn, Suwon 440746, South Korea
[2] Sungkyunkwan Univ, Dept Mech Engn, Suwon 440746, South Korea
[3] Univ Management & Technol, Dept Ind Engn, Lahore 54770, Pakistan
基金
新加坡国家研究基金会;
关键词
Convolutional neural network (CNN) based reclosing; single-phase auto-reclosing; secondary arc extinction; transmission line auto-reclosing; ARC EXTINCTION TIME; TRANSMISSION-LINES; ALGORITHM;
D O I
10.1109/TPWRD.2022.3159256
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Single-phaseauto-reclosing schemes depend on two main characteristics:(i) secondary arc extinction instant (ii) fault type (temporary or permanent). However, secondary arc quenching time greatly varies from no-arc to prolonged-arc generation depending on the secondary arc current and meteorological factors (wind, thermal buoyancy, etc.). Existing solutions face challenges in making reclosing decisions owing to variable secondary arc quenching instant, non-linear arc voltage characteristics, and varying recovery voltage waveform magnitude. To comprehensively address the discussed problems, an approach based on a particle filter algorithm along with a convolutional neural network is developed. Initially, harmonics of compromised phase are online estimated using a particle filter algorithm, and two indices are developed: (i) estimation of the precise moment of secondary arc extinction (ii) fault nature. Then, extensive simulations are carried out with variable arc resistance, line lengths, no-shunt, and shunt configurations to develop a database based on these two indices. Finally, support vector machine, fully connected deep neural network, and the convolutional neural network are applied to the dataset to predict the reclosing decisions. The comparative study of classifiers confirms the effectiveness of the proposed convolutional neural network in terms of overall model and inter-class accuracy under a noisy and noise-free environment.
引用
收藏
页码:4775 / 4785
页数:11
相关论文
共 50 条
  • [1] Single-phase auto-reclosing of the Vietnam 500 kV system
    Tran-Quoc, T
    Huy, HVV
    Duong-Lan, H
    Hoang, LNT
    Tran-Dinh, L
    POWERCON '98: 1998 INTERNATIONAL CONFERENCE ON POWER SYSTEM TECHNOLOGY - PROCEEDINGS, VOLS 1 AND 2, 1998, : 1077 - 1081
  • [2] Adaptive single-phase auto-reclosing method using power line carrier signals
    Hamidi, Reza Jalilzadeh
    Livani, Hanif
    INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2018, 96 : 64 - 73
  • [3] Phasor-Based Single-Phase Auto-Reclosing Scheme for Non-Compensated Transmission Lines
    Dantas, Karcius M. C.
    Lopes, Felipe V.
    Silva, Kleber M.
    Costa, Flavio B.
    Ribeiro, Nilo S. S.
    IEEE TRANSACTIONS ON POWER DELIVERY, 2022, 37 (01) : 219 - 229
  • [4] Adaptive Single-Phase Auto-Reclosing Approach for Shunt Compensated Transmission Lines
    Ahmadi, Seyed-Alireza
    Sanaye-Pasand, Majid
    Jafarian, Peyman
    Mehrjerdi, Hasan
    IEEE TRANSACTIONS ON POWER DELIVERY, 2021, 36 (03) : 1360 - 1369
  • [5] SINGLE-PHASE AUTO-RECLOSING ON 750-KV TRANSMISSIONS WITH SHUNT REACTORS
    BELYAKOV, NN
    BURGSDORF, VV
    RASHKES, VS
    KHOETSIAN, KV
    ELECTRICAL TECHNOLOGY, 1981, (03): : 14 - 27
  • [6] Optimizing multi-circuit transmission lines for single-phase auto-reclosing*
    Acosta, Jhair S.
    Tavares, Maria C.
    Gole, Aniruddha M.
    ELECTRIC POWER SYSTEMS RESEARCH, 2021, 197
  • [7] An adaptive single-phase auto-reclosing scheme based on the Hausdorff distance algorithm for transmission lines with shunt reactors
    Liu, Yangsheng
    Dou, Kun
    Xie, Xing
    Huang, Zebo
    Luo, Yi
    Tang, Tao
    Liang, Haonan
    COMPUTERS & ELECTRICAL ENGINEERING, 2025, 122
  • [8] A novel phasor-based adaptive single-phase auto-reclosing scheme for transmission lines with shunt reactors
    Liu, Yangsheng
    Dou, Kun
    Xie, Xing
    Huang, Zebo
    Huang, Qian
    Guo, Zhenwei
    Luo, Yi
    Tang, Tao
    ELECTRICAL ENGINEERING, 2024, 106 (06) : 7231 - 7245
  • [9] Adaptive single-phase auto-reclosing scheme based on the moving average filter-quadrature signal generator for transmission lines with shunt reactors
    Xie, Xing
    Huang, Zebo
    Fan, Xingming
    Tang, Tao
    ELECTRIC POWER SYSTEMS RESEARCH, 2023, 223
  • [10] Single-phase auto-reclosing mitigation procedure for half-wavelength transmission line
    Dias, Ozenir
    Tavares, Maria Cristina