EXPERIMENTAL METHODS FOR IMPROVED SPATIAL CONTROL OF THERMAL LESIONS IN MAGNETIC RESONANCE-GUIDED FOCUSED ULTRASOUND ABLATION

被引:10
|
作者
Viallon, Magalie [1 ]
Petrusca, Lorena [2 ]
Auboiroux, Vincent [2 ]
Goget, Thomas [2 ]
Baboi, Loredana [2 ]
Becker, Christoph D. [2 ]
Salomir, Rares [1 ,2 ]
机构
[1] Univ Hosp Geneva, Dept Radiol, CH-1211 Geneva, Switzerland
[2] Univ Geneva, Fac Med, Geneva, Switzerland
来源
ULTRASOUND IN MEDICINE AND BIOLOGY | 2013年 / 39卷 / 09期
基金
瑞士国家科学基金会;
关键词
Magnetic resonance-guided high-intensity focused ultrasound; Cavitation; Boiling core; Safety profile; Targeting; Pre-clinical quality assurance; BREAST-CANCER; PHASED-ARRAY; NONINVASIVE SURGERY; RADIATION FORCE; MRI; CAVITATION; THERAPY; HYPERTHERMIA; FEASIBILITY; TRANSDUCER;
D O I
10.1016/j.ultrasmedbio.2013.03.018
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Magnetic resonance-guided high-intensity focused ultrasound (MRgHIFU, or MRgFUS) is a hybrid technology that was developed to provide efficient and tolerable thermal ablation of targeted tumors or other pathologic tissues, while preserving the normal surrounding structures. Fast 3-D ablation strategies are feasible with the newly available phased-array HIFU transducers. However, unlike fixed heating sources for interstitial ablation (radiofrequency electrode, microwave applicator, infra-red laser applicator), HIFU uses propagating waves. Therefore, the main challenge is to avoid thermo-acoustical adverse effects, such as energy deposition at reflecting interfaces and thermal drift of the focal lesion toward the near field. We report here our investigations on some novel experimental solutions to solve, or at least to alleviate, these generally known tolerability problems in HIFU-based therapy. Online multiplanar MR thermometry was the main investigational tool extensively used in this study to identify the problems and to assess the efficacy of the tested solutions. We present an improved method to cancel the beam reflection at the exit window (i.e., tissue-to-air interface) by creating a multilayer protection, to dissipate the residual HIFU beam by bulk scattering. This study evaluates selective de-activation of transducer elements to reduce the collateral heating at bone surfaces in the far field, mainly during automatically controlled volumetric ablation. We also explore, using hybrid US/MR simultaneous imaging, the feasibility of using disruptive boiling at the focus, both as a far-field self-shielding technique and as an enhanced ablation strategy (i.e., boiling core controlled HIFU ablation). (E-mail: magalie.viallon@hcuge.ch) (c) 2013 World Federation for Ultrasound in Medicine & Biology.
引用
收藏
页码:1580 / 1595
页数:16
相关论文
共 50 条
  • [1] Magnetic resonance-guided focused ultrasound
    Albuquerque, Felipe C.
    NEUROSURGICAL FOCUS, 2013, 34 (05)
  • [2] Volumetric analysis of magnetic resonance-guided focused ultrasound thalamotomy lesions
    Harary, Maya
    Essayed, Walid I.
    Valdes, Pablo A.
    McDannold, Nathan
    Cosgrove, G. Rees
    NEUROSURGICAL FOCUS, 2018, 44 (02)
  • [3] Magnetic Resonance-Guided Focused Ultrasound Surgery
    Al Hilli, Mariam M.
    Stewart, Elizabeth A.
    SEMINARS IN REPRODUCTIVE MEDICINE, 2010, 28 (03) : 241 - 248
  • [4] Magnetic resonance-guided focused ultrasound surgery
    Hudson, Susan B. A.
    Stewart, Elizabeth A.
    CLINICAL OBSTETRICS AND GYNECOLOGY, 2008, 51 (01): : 159 - 166
  • [5] Magnetic resonance-guided focused ultrasound surgery
    Schwalb, Jason M.
    JOURNAL OF NEUROSURGERY, 2013, 119 (02) : 531 - 531
  • [6] Magnetic Resonance-Guided High Intensity Focused Ultrasound Ablation of Breast Cancer
    Knuttel, Floortje M.
    van den Bosch, Maurice A. A. J.
    THERAPEUTIC ULTRASOUND, 2016, 880 : 65 - 81
  • [7] Magnetic Resonance-Guided Focused Ultrasound for Psychiatric Disorders
    Davidson, Benjamin
    Meng, Ying
    Giacobbe, Peter
    Hamani, Clement
    Lipsman, Nir
    CLINICAL PHARMACOLOGY & THERAPEUTICS, 2019, 106 (04) : 720 - 722
  • [8] Magnetic resonance-guided focused ultrasound and essential tremor
    Gallay, Marc
    Jeanmonod, Daniel
    NEUROSURGICAL FOCUS, 2018, 45 (01)
  • [9] Intracranial Applications of Magnetic Resonance-guided Focused Ultrasound
    Nir Lipsman
    Todd G. Mainprize
    Michael L. Schwartz
    Kullervo Hynynen
    Andres M. Lozano
    Neurotherapeutics, 2014, 11 : 593 - 605
  • [10] Magnetic resonance-guided focused ultrasound for the treatment of tremor
    Yamamoto, Kazuaki
    Sarica, Can
    Loh, Aaron
    Vetkas, Artur
    Samuel, Nardin
    Milano, Vanessa
    Zemmar, Ajmal
    Germann, Juergen
    Cheyuo, Cletus
    Boutet, Alexandre
    Elias, Gavin J. B.
    Ito, Hisashi
    Taira, Takaomi
    Lozano, Andres M.
    EXPERT REVIEW OF NEUROTHERAPEUTICS, 2022, 22 (10) : 849 - 861