A novel method for using accelerometer data to predict energy expenditure

被引:303
作者
Crouter, SE [1 ]
Clowers, KG [1 ]
Bassett, DR [1 ]
机构
[1] Univ Tennessee, Dept Exercise Sport & Leisure Studies, Knoxville, TN USA
关键词
motion sensor; physical activity; oxygen consumption; activity counts variability;
D O I
10.1152/japplphysiol.00818.2005
中图分类号
Q4 [生理学];
学科分类号
071003 ;
摘要
The purpose of this study was to develop a new two-regression model relating Actigraph activity counts to energy expenditure over a wide range of physical activities. Forty-eight participants [age 35 yr (11.4)] performed various activities chosen to represent sedentary, light, moderate, and vigorous intensities. Eighteen activities were split into three routines with each routine being performed by 20 individuals, for a total of 60 tests. Forty-five tests were randomly selected for the development of the new equation, and 15 tests were used to cross-validate the new equation and compare it against already existing equations. During each routine, the participant wore an Actigraph accelerometer on the hip, and oxygen consumption was simultaneously measured by a portable metabolic system. For each activity, the coefficient of variation ( CV) for the counts per 10 s was calculated to determine whether the activity was walking/running or some other activity. If the CV was <= 10, then a walk/run regression equation was used, whereas if the CV was > 10, a lifestyle/leisure time physical activity regression was used. In the cross-validation group, the mean estimates using the new algorithm (2-regression model with an inactivity threshold) were within 0.75 metabolic equivalents (METs) of measured METs for each of the activities performed (P >= 0.05), which was a substantial improvement over the single-regression models. The new algorithm is more accurate for the prediction of energy expenditure than currently published regression equations using the Actigraph accelerometer.
引用
收藏
页码:1324 / 1331
页数:8
相关论文
共 18 条
[1]  
American College of Sports Medicine, 2000, ACSMS GUID EX TEST P
[2]   Validity of four motion sensors in measuring moderate intensity physical activity [J].
Bassett, DR ;
Ainsworth, BE ;
Swartz, AM ;
Strath, SJ ;
O'Brien, WL ;
King, GA .
MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2000, 32 (09) :S471-S480
[3]   CHANGES IN PHYSICAL-FITNESS AND ALL-CAUSE MORTALITY - A PROSPECTIVE-STUDY OF HEALTHY AND UNHEALTHY MEN [J].
BLAIR, SN ;
KOHL, HW ;
BARLOW, CE ;
PAFFENBARGER, RS ;
GIBBONS, LW ;
MACERA, CA .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1995, 273 (14) :1093-1098
[4]   PHYSICAL-FITNESS AND INCIDENCE OF HYPERTENSION IN HEALTHY NORMOTENSIVE MEN AND WOMEN [J].
BLAIR, SN ;
GOODYEAR, NN ;
GIBBONS, LW ;
COOPER, KH .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1984, 252 (04) :487-490
[5]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[6]   Reexamination of validity and reliability of the CSA monitor in walking and running [J].
Brage, S ;
Wedderkopp, N ;
Franks, PW ;
Andersen, LB ;
Froberg, K .
MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2003, 35 (08) :1447-1454
[7]   HEPATIC PERIPORTAL NECROSIS INDUCED BY CHRONIC ADMINISTRATION OF COCAINE [J].
FREEMAN, RW ;
HARBISON, RD .
BIOCHEMICAL PHARMACOLOGY, 1981, 30 (07) :777-783
[8]   Validity of accelerometry for the assessment of moderate intensity physical activity in the field [J].
Hendelman, D ;
Miller, K ;
Bagget, C ;
Debold, E ;
Freedson, P .
MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2000, 32 (09) :S442-S449
[9]   Comparison of activity monitors to estimate energy cost of treadmill exercise [J].
King, GA ;
Torres, N ;
Potter, C ;
Brooks, TJ ;
Coleman, KJ .
MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2004, 36 (07) :1244-1251
[10]   Physical activity and coronary heart disease risk in men - Does the duration of exercise episodes predict risk? [J].
Lee, IM ;
Sesso, HD ;
Paffenbarger, RS .
CIRCULATION, 2000, 102 (09) :981-986