In vitro biomechanical evaluation of sagittal split osteotomy fixation with a specifically designed miniplate

被引:21
|
作者
Pereira Filho, V. A. [1 ]
Iamashita, H. Y. [1 ]
Monnazzi, M. S. [1 ]
Gabrielli, M. F. R. [1 ]
Vaz, L. G. [1 ]
Passeri, L. A. [1 ]
机构
[1] Univ Estadual Paulista, Dept Diag & Oral & Maxillofacial Surg, Dent Sch Araraquara, BR-14801903 Sao Paulo, Brazil
关键词
biomechanical evaluation; sagittal split ramus osteotomy; rigid internal fixation; RIGID INTERNAL-FIXATION; RAMUS OSTEOTOMY; MANDIBULAR SETBACK; ADVANCEMENT SURGERY; PLATE FIXATION; SCREW FIXATION; STABILITY; PATTERN; SYSTEM;
D O I
10.1016/j.ijom.2012.07.008
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Recent studies have evaluated many methods of internal fixation for sagittal split ramus osteotomy (SSRO), aiming to increase stability of the bone segments while minimizing condylar displacement. The purpose of this study was to evaluate, through biomechanical testing, the stability of the fixation comparing a specially designed bone plate to other two commonly used methods. Thirty hemimandibles were separated into three equal groups. All specimens received SSRO. In Group I the osteotomies were fixed with three 15 mm bicortical positional screws in an inverted-L pattern with an insertion angle of 90 degrees. In Group II, fixation was carried out with a four-hole straight plate and four 6 mm monocortical screws. In Group III, fixation was performed with an adjustable sagittal plate and eight 6 mm monocortical screws. Hemimandibles were submitted to vertical compressive loads, by a mechanical testing unit. Averages and standard deviations were submitted to analysis of variance using the Tukey test with a 5% level of significance. Bicortical screws presented the greatest values of loading resistance. The adjustable miniplate demonstrated 60% lower resistance compared to bicortical screws. Group II presented on average 40% less resistant to the axial loading.
引用
收藏
页码:316 / 320
页数:5
相关论文
共 50 条
  • [1] In Vitro Biomechanical Evaluation of the Use of Conventional and Locking Miniplate/Screw Systems for Sagittal Split Ramus Osteotomy
    Ribeiro-Junior, Paulo Domingos
    Magro-Filho, Osvaldo
    Shastri, Kalpakam A.
    Papageorge, Maria B.
    JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2010, 68 (04) : 724 - 730
  • [2] In vitro biomechanical evaluation of fixation methods of sagittal split ramus osteotomy in mandibular setback
    Oh, Ji-Su
    Kim, Su-Gwan
    JOURNAL OF CRANIO-MAXILLOFACIAL SURGERY, 2015, 43 (02) : 186 - 191
  • [3] In vitro comparison of biomechanical characteristics of sagittal split osteotomy fixation techniques
    Oezden, B.
    Alkan, A.
    Arici, S.
    Erdem, E.
    INTERNATIONAL JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2006, 35 (09) : 837 - 841
  • [4] Evaluation of mandibular setback after bilateral sagittal split osteotomy with the hunsuck modification and miniplate fixation
    Yang, Xue-Wen
    Long, Xing
    Yeweng, San-Jie
    Kao, Chia-Tze
    JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2007, 65 (11) : 2176 - 2180
  • [5] Biomechanical Evaluation of Sagittal Split Ramus Osteotomy Fixation Techniques in Mandibular Setback
    Chen, Michael Y. C.
    Wu, Yi-Fan
    Huang, Heng-Li
    Hsu, Jui-Ting
    APPLIED SCIENCES-BASEL, 2020, 10 (09):
  • [6] Fixation methods in sagittal split ramus osteotomy: a systematic review on in vitro biomechanical assessments
    Kuik, K.
    De Ruiter, M. H. T.
    De Lange, J.
    Hoekema, A.
    INTERNATIONAL JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2019, 48 (01) : 56 - 70
  • [7] Biomechanical evaluation of hybrid fixation method of sagittal split ramus osteotomy in mandibular advancement
    Gursoytrak, Burcu
    Unsal, Nurdan
    Demetoglu, Umut
    Simsek, Hasan Onur
    Saglam, Haci
    Dolanmaz, Dogan
    JOURNAL OF CRANIO-MAXILLOFACIAL SURGERY, 2018, 46 (12) : 2063 - 2068
  • [8] Which kind of miniplate to use in mandibular sagittal split osteotomy? An in vitro study
    Ribeiro-Junior, P. D.
    Magro-Filho, O.
    Shastri, K. A.
    Papageorge, M. B.
    INTERNATIONAL JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2012, 41 (11) : 1369 - 1373
  • [9] Biomechanical evaluation of a T-shaped miniplate fixation of a modified sagittal split ramus osteotomy with buccal step, a new technique for mandibular orthognathic surgery
    Aymach, Zaher
    Nei, Hitoshi
    Kawamura, Hiroshi
    Bell, William
    ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTOLOGY, 2011, 111 (01): : 58 - 63
  • [10] SKELETAL STABILITY FOLLOWING MINIPLATE FIXATION AFTER BILATERAL SAGITTAL SPLIT OSTEOTOMY FOR MANDIBULAR ADVANCEMENT
    ABELOOS, J
    DECLERCQ, C
    NEYT, L