Efficient Reconstruction Technique for Multi-Slice CS-MRI Using Novel Interpolation and 2D Sampling Scheme

被引:9
|
作者
Murad, Maria [1 ]
Bilal, Muhammad [1 ]
Jalil, Abdul [1 ]
Ali, Ahmad [2 ]
Mehmood, Khizer [1 ]
Khan, Baber [1 ]
机构
[1] Int Islamic Univ Islamabad, Dept Elect Engn, Islamabad 44000, Pakistan
[2] Bahria Univ, Dept Software Engn, Islamabad 44000, Pakistan
关键词
Compressed sensing; compressed sensing reconstruction; interpolated compressed sensing; magnetic resonance imaging; multi-slice MRI; nonlinear conjugate gradient; IMAGE-RECONSTRUCTION; SPARSITY;
D O I
10.1109/ACCESS.2020.3004731
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Compressed Sensing (CS) theory breaks the Nyquist theorem through random under-sampling and enables us to reconstruct a signal from 10%-50% samples. Magnetic Resonance Imaging (MRI) is a good candidate for application of compressed sensing techniques due to i) implicit sparsity in MR images and ii) inherently slow data acquisition process. In multi-slice MRI, strong inter-slice correlation has been exploited for further scan time reduction through interpolated compressed sensing (iCS). In this paper, a novel fast interpolated compressed sensing (FiCS) technique is proposed based on 2D variable density under-sampling (VRDU) scheme. The 2D-VRDU scheme improves the result by sampling the high energy central part of the k-space slices. The novel interpolation technique takes two consecutive slices and estimates the missing samples of the target slice (T slice) from its left slice (L slice). Compared to the previous methods, slices recovered with the proposed FiCS technique have a maximum correlation with their corresponding original slices. The proposed FiCS technique is evaluated by using both subjective and objective assessment. In subjective assessment, our proposed technique shows less partial volume loss compared to existing techniques. For objective assessment different performance metrics, such as structural similarity index measurement (SSIM), peak signal to noise ratio (PSNR), mean square error (MSE) and correlation, are used and compared with existing interpolation techniques. Simulation results on knee and brain dataset shows that the proposed FiCS technique has improved image quality and performance with even reduced scan time, lower computational complexity and maximum information content.
引用
收藏
页码:117452 / 117466
页数:15
相关论文
共 50 条
  • [1] Learing Sampling and Reconstruction Using Bregman Iteration for CS-MRI
    Fei, Tiancheng
    Feng, Xiangchu
    ELECTRONICS, 2023, 12 (22)
  • [2] An Efficient Interpolated Compressed Sensing Method for Highly Correlated 2D Multi-slice MRI
    Datta, Sumit
    Deka, Bhabesh
    Mullah, Helal Uddin
    Kumar, Sushant
    2016 INTERNATIONAL CONFERENCE ON ACCESSIBILITY TO DIGITAL WORLD (ICADW), 2016, : 187 - 192
  • [3] Performance Analysis of CS-MRI Reconstruction using Particle Swarm Optimization for different Sampling Patterns
    Manisha
    Shrividya, G.
    Bharathi, S. H.
    2017 2ND IEEE INTERNATIONAL CONFERENCE ON RECENT TRENDS IN ELECTRONICS, INFORMATION & COMMUNICATION TECHNOLOGY (RTEICT), 2017, : 205 - 208
  • [4] Segmented multiple plane reconstruction: a novel approximate reconstruction scheme for multi-slice spiral CT
    Stierstorfer, K
    Flohr, T
    Bruder, H
    PHYSICS IN MEDICINE AND BIOLOGY, 2002, 47 (15): : 2571 - 2581
  • [5] PALADIN: a novel plug-and-play 3D CS-MRI reconstruction method
    Wu, Jia-Mian
    Yin, Shi-Bai
    Jiang, Tai-Xiang
    Liu, Gui-Song
    Zhao, Xi-Le
    INVERSE PROBLEMS, 2025, 41 (03)
  • [6] Outline Information and Multiple Variable Density SamplingSimultaneous Multi-slice MRI Reconstruction Using
    Fang, Yongxiang
    Chen, Lin
    Sun, Jiabing
    Huang, Jiawen
    Zhang, Huabin
    Qiu, Bensheng
    2024 9TH INTERNATIONAL CONFERENCE ON SIGNAL AND IMAGE PROCESSING, ICSIP, 2024, : 726 - 730
  • [7] An efficient super-resolution approach for obtaining isotropic 3-D imaging using 2-D multi-slice MRI
    Hefnawy, Alaa A.
    EGYPTIAN INFORMATICS JOURNAL, 2013, 14 (02) : 117 - 123
  • [8] Analytical corrections for B1-inhomogeneity and signal decay in multi-slice 2D spiral hyperpolarized 129Xe MRI using keyhole reconstruction
    Plummer, J. W.
    Hussain, R.
    Bdaiwi, A. S.
    Costa, M. L.
    Willmering, M. M.
    Parra-Robles, J.
    Cleveland, Z. I.
    Walkup, L. L.
    MAGNETIC RESONANCE IN MEDICINE, 2024, 92 (03) : 967 - 981
  • [9] Quantitative myocardial perfusion with a hybrid 2D simultaneous multi-slice sequence
    Huang, Qi
    Tian, Ye
    Mendes, Jason
    Ranjan, Ravi
    Adluru, Ganesh
    DiBella, Edward
    MAGNETIC RESONANCE IMAGING, 2023, 98 : 7 - 16
  • [10] Simultaneous multi-slice image reconstruction using regularized image domain split slice-GRAPPA for diffusion MRI
    HashemizadehKolowri, Sk
    Chen, Rong-Rong
    Adluru, Ganesh
    Dean, Douglas C.
    Wilde, Elisabeth A.
    Alexander, Andrew L.
    DiBella, Edward V. R.
    MEDICAL IMAGE ANALYSIS, 2021, 70