Evaluation of the efficiency and effectiveness of independent dose calculation followed by machine log file analysis against conventional measurement based IMRT QA

被引:49
|
作者
Sun, Baozhou [1 ]
Rangaraj, Dharanipathy [1 ,2 ]
Boddu, Sunita [3 ]
Goddu, Murty [1 ]
Yang, Deshan [1 ]
Palaniswaamy, Geethpriya [2 ]
Yaddanapudi, Sridhar [1 ]
Wooten, Omar [1 ]
Mutic, Sasa [1 ]
机构
[1] Washington Univ, Sch Med, Dept Radiat Oncol, St Louis, MO 63130 USA
[2] Scott & White Healthcare Syst, Dept Radiat Oncol, Temple, TX USA
[3] Univ Calif Davis, Dept Radiat Oncol, Sacramento, CA 95817 USA
来源
关键词
quality assurance; IMRT; dose calculations; machine log file; STEP-AND-SHOOT; QUALITY-ASSURANCE; RADIATION-THERAPY; TREATMENT PLAN; VERIFICATION; VALIDATE; DELIVERY; DOCUMENT; PHOTON;
D O I
10.1120/jacmp.v13i5.3837
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Experimental methods are commonly used for patient-specific IMRT delivery verification. There are a variety of IMRT QA techniques which have been proposed and clinically used with a common understanding that not one single method can detect all possible errors. The aim of this work was to compare the efficiency and effectiveness of independent dose calculation followed by machine log file analysis to conventional measurement-based methods in detecting errors in IMRT delivery. Sixteen IMRT treatment plans (5 head-and-neck, 3 rectum, 3 breast, and 5 prostate plans) created with a commercial treatment planning system (TPS) were recalculated on a QA phantom. All treatment plans underwent ion chamber (IC) and 2D diode array measurements. The same set of plans was also recomputed with another commercial treatment planning system and the two sets of calculations were compared. The deviations between dosimetric measurements and independent dose calculation were evaluated. The comparisons included evaluations of DVHs and point doses calculated by the two TPS systems. Machine log files were captured during pretreatment composite point dose measurements and analyzed to verify data transfer and performance of the delivery machine. Average deviation between IC measurements and point dose calculations with the two TPSs for head-and-neck plans were 1.2 +/- 1.3% and 1.4 +/- 1.6%, respectively. For 2D diode array measurements, the mean gamma value with 3% dose difference and 3 mm distance-to-agreement was within 1.5% for 13 of 16 plans. The mean 3D dose differences calculated from two TPSs were within 3% for head-and-neck cases and within 2% for other plans. The machine log file analysis showed that the gantry angle, jaw position, collimator angle, and MUs were consistent as planned, and maximal MLC position error was less than 0.5 mm. The independent dose calculation followed by the machine log analysis takes an average 47 +/- 6 minutes, while the experimental approach (using IC and 2D diode array measurements) takes an average about 2 hours in our clinic. Independent dose calculation followed by machine log file analysis can be a reliable tool to verify IMRT treatments. Additionally, independent dose calculations have the potential to identify several problems (heterogeneity calculations, data corruptions, system failures) with the primary TPS, which generally are not identifiable with a measurement-based approach. Additionally, machine log file analysis can identify many problems (gantry, collimator, jaw setting) which also may not be detected with a measurement-based approach. Machine log file analysis could also detect performance problems for individual MLC leaves which could be masked in the analysis of a measured fluence.
引用
收藏
页码:140 / 154
页数:15
相关论文
共 15 条
  • [1] Independent Dose Calculation Followed by Dynalog File Analysis as an Alternative for Measurement Based IMRT QA
    Sun, B.
    Boddu, S.
    Goddu, S.
    Yang, D.
    Rangaraj, D.
    Mutic, S.
    MEDICAL PHYSICS, 2011, 38 (06)
  • [2] An independent platform dose calculation and log file evaluation in proton therapy
    Fonseca, G.
    Almeida, I.
    Wagenberg, T.
    Wolfs, C.
    Freixas, G. Vilches
    Rinaldi, I.
    Martens, J.
    Bosmans, G.
    Verhaegen, F.
    RADIOTHERAPY AND ONCOLOGY, 2020, 152 : S124 - S124
  • [3] Dependence of Log File Based IMRT QA of Lung SBRT Plans On TPS Dose Algorithm
    Baltz, G.
    Manigold, R.
    Kirsner, S.
    MEDICAL PHYSICS, 2022, 49 (06) : E901 - E901
  • [4] Comparison of Log File Based Dose Reconstruction to Measurement for Patient Specific QA
    Lesieur, R.
    Schneider, C. W.
    MEDICAL PHYSICS, 2024, 51 (09) : 6635 - 6635
  • [5] IMRT QA: comparing independent recalculation against measurement based methods
    Kry, S.
    Glenn, M.
    Peterson, C.
    Branco, D.
    Mehrens, H.
    Steinmann, A.
    Followill, D.
    RADIOTHERAPY AND ONCOLOGY, 2019, 133 : S319 - S320
  • [6] 2D dose reconstruction of IMRT patient-specific QA based on log file
    Mubarok, Sayid
    Wahyu, Wibowo Edy
    Supriyanto, Pawiro Ardjo
    RADIATION PHYSICS AND CHEMISTRY, 2020, 166
  • [7] Clinical implementation of a log file-based machine and patient QA system for IMRT and VMAT treatment plans
    Silvestri, Valerio
    Raspanti, Davide
    Guerrisi, Maria Giovanna
    Falco, Maria Daniela
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2023, 108
  • [8] Parallel/Opposed: IMRT QA using treatment log files is superior to conventional measurement-based method
    Childress, Nathan
    Chen, Quan
    Rong, Yi
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2015, 16 (01): : 4 - 7
  • [9] Comparing Measurement Derived (3DVH) and Machine Log File Derived Dose Reconstruction Methods for VMAT QA in Heterogeneous Patient Geometries
    Tyagi, N.
    Yang, K.
    Yan, D.
    MEDICAL PHYSICS, 2013, 40 (06)
  • [10] A Novel QA Process Based On Monte Carlo 2nd Check and Dose Reconstruction From Machine Log File On TomoTherapy
    Chen, Q.
    Handsfield, L.
    Wilson, D.
    Larner, J.
    Read, P.
    MEDICAL PHYSICS, 2013, 40 (06)