Application of displacement monitoring system on high temperature steam pipe

被引:1
|
作者
Ghaffar, M. H. A. [1 ]
Husin, S. [1 ]
Baek, J. E. [2 ]
机构
[1] TNB Res Sdn, Kawasan Inst Penyelidikan & Latihan Bangi, Mat Engn Grp, Bhd Lorong Ayer Itam, Kajang 43000, Selangor, Malaysia
[2] Korea Leading Engn Syst, 40 Techno 3 Ro, Daejeon, South Korea
关键词
D O I
10.1088/1757-899X/257/1/012026
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
High-energy piping systems of power plants such as Main Steam (MS) pipe or Hot Reheat (HR) pipe are operating at high temperature and high pressure at base and cyclic loads. In the event of transient condition, a pipe can be deflected dramatically and caused high stress in the pipe, yielding to failure of the piping system. Periodic monitoring and walk down can identify abnormalities but limitations exist in the standard walk down practice. This paper provides a study of pipe displacement monitoring on MS pipe of coal-fired power plant to continuously capture the pipe movement behaviour at different load using 3-Dimensional Displacement Measuring System (3DDMS). The displacement trending at Location 5 and 6 (north and south) demonstrated pipes displace less than 25% to that of design movement. It was determined from synchronisation analysis that Location 7 (north) and Location 8 (south) pipe actual movement difference has exceeded the design movement difference. Visual survey at specified locations with significant displacement trending reveals issues of hydraulic snubber and piping interferences. The study demonstrated that the displacement monitoring is able to capture pipe movement at all time and allows engineer to monitor pipe movement behaviour, aids in identifying issue early for remedy action.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] Real-time displacement monitoring system for high temperature steam pipe of fossil power plant
    Hyun, JS
    Song, GW
    Cho, SY
    Lee, YS
    ADVANCES IN FRACTURE AND STRENGTH, PTS 1- 4, 2005, 297-300 : 2164 - 2168
  • [2] Development of on-line displacement monitoring system for high temperature steam pipe of fossil power plant
    Wook, SG
    Seob, HJ
    Young, CS
    BALTICA VI: LIFE MANAGEMENT AND MAINTENANCE FOR POWER PLANTS, VOL 1 AND 2, 2004, 233-234 : 635 - 646
  • [3] Development of on-line displacement monitoring system for high temperature steam pipe of fossil power plant
    Wook, Song Gee
    Seob, Hyun Jung
    Young, Cho Sun
    VTT Symposium (Valtion Teknillinen Tutkimuskeskus), 2004, (234): : 635 - 646
  • [4] The design and application of remote monitoring system on working condition of trap in steam pipe network
    Wu Xiaolei
    Yu Xingjiang
    Ye Shengli
    Xia Yunfei
    PROCEEDINGS OF THE 2016 INTERNATIONAL FORUM ON MANAGEMENT, EDUCATION AND INFORMATION TECHNOLOGY APPLICATION, 2016, 47 : 552 - 559
  • [5] Development of Leak and Vibration Monitoring System for High Pressure Steam Pipe by Using a Camera
    Jeon, Hyeong-Seop
    Suh, Jang-Su
    Chae, Gyung-Sun
    Son, Ki-Sung
    Kim, Se-Oh
    Lee, Nam-Hee
    JOURNAL OF THE KOREAN SOCIETY FOR NONDESTRUCTIVE TESTING, 2016, 36 (06) : 496 - 503
  • [6] High temperature steam pipelines - Development of the ARCMAC creep monitoring system
    Morris, A.
    Dear, J.
    Kourmpetis, M.
    STRAIN, 2006, 42 (03) : 181 - 185
  • [7] In-service monitoring of steam pipe systems at high temperatures
    Bar-Cohen, Yoseph
    Lih, Shyh-Shiuh
    Badescu, Mircea
    Bao, Xiaoqi
    Sherrit, Stewart
    Widholm, Scott
    Scott, Jim
    Blosiu, Julian
    HEALTH MONITORING OF STRUCTURAL AND BIOLOGICAL SYSTEMS 2010, PTS 1 AND 2, 2010, 7650
  • [8] Reliable detection of pipe support malfunctions with the displacement monitoring system DIMOS
    Winterstein, M.
    Binder, F.
    VDI Berichte, 2003, (1769): : 67 - 76
  • [9] The Design and Application of the Vertical Displacement Monitoring System in the Dam
    Li Jue
    Wu Chuangfu
    Gao Li
    Li Yiming
    PROCEEDINGS OF THE 3RD INTERNATIONAL YELLOW RIVER FORUM ON SUSTAINABLE WATER RESOURCES MANAGEMENT AND DELTA ECOSYSTEM MAINTENANCE, VOL IV, 2007, : 264 - 269
  • [10] High temperatures health monitoring of the condensed water height in steam pipe systems
    Lee, Hyeong Jae
    Bar-Cohen, Yoseph
    Lih, Shyh-Shiuh
    Badescu, Mircea
    Bao, Xiaoqi
    Sherrit, Stewart
    Takano, Nobuyuki
    Ostlund, Patrick
    Blosiu, Julian
    HEALTH MONITORING OF STRUCTURAL AND BIOLOGICAL SYSTEMS 2013, 2013, 8695