Determining the true slip of a yield stress material with a sliding plate rheometer

被引:19
|
作者
Clasen, Christian [1 ]
机构
[1] Univ Leuven KU Leuven, Dept Chem Engn, B-3001 Heverlee, Belgium
关键词
Slip; Yield stress; Xanthan gum solution; Mooney equation; Sliding plate; Rheometer; Yielding; PARALLEL-DISK VISCOMETERS; WALL-SLIP; DENSITY POLYETHYLENE; POLYMER-SOLUTIONS; COMPLEX FLUIDS; FLOW; RHEOLOGY; EMULSIONS; VISCOSITY; COUETTE;
D O I
10.1007/s00397-012-0647-5
中图分类号
O3 [力学];
学科分类号
08 ; 0801 ;
摘要
Within this paper we demonstrate the capability of the sliding plate configuration of the flexure-based microgap rheometer (FMR) to absolutely determine slip velocities of a yield stress fluid. The sensitivity of the compound flexures of the FMR in combination with the possibility to achieve precise gap settings down to 1 mu m allows to accurately determining slip velocities down to 1 mu m/s. We further show how the obtained non-linear relation of the slip velocity to the constant stresses of the plane Couette flow in the sliding plate configuration of the FMR allows predicting and explaining the inhomogeneous stress distribution and partial yielding behaviour in a rotational cone-and-plate geometry.
引用
收藏
页码:883 / 890
页数:8
相关论文
共 50 条
  • [1] Determining the true slip of a yield stress material with a sliding plate rheometer
    Christian Clasen
    Rheologica Acta, 2012, 51 : 883 - 890
  • [2] Dynamic response of a shear stress transducer in the sliding plate rheometer
    Kolitawong, C
    Giacomin, AJ
    JOURNAL OF NON-NEWTONIAN FLUID MECHANICS, 2002, 102 (01) : 71 - 96
  • [3] Determining true material constants of viscoplastic materials from rotational rheometer data
    Alexandrou, Andreas N.
    Georgiou, Georgios C.
    Economides, Eva-Athena
    Zang, Christoph
    Modigell, Michael
    JOURNAL OF NON-NEWTONIAN FLUID MECHANICS, 2018, 260 : 101 - 108
  • [4] Frequency response of a shear stress transducer installed in a sliding plate rheometer
    Dealy, JM
    Jeyaseelan, RS
    JOURNAL OF RHEOLOGY, 1998, 42 (04) : 833 - 841
  • [5] Evaluation of yield stress measurement techniques on a parallel plate magnetic rheometer
    Ulicny, John C.
    Golden, Mark A.
    INTERNATIONAL JOURNAL OF MODERN PHYSICS B, 2007, 21 (28-29): : 4898 - 4906
  • [6] A sliding plate microgap rheometer for the simultaneous measurement of shear stress and first normal stress difference
    Baik, Seung Jae
    Moldenaers, Paula
    Clasen, Christian
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2011, 82 (03):
  • [7] A NOVEL SLIDING PLATE RHEOMETER FOR MOLTEN PLASTICS
    GIACOMIN, AJ
    SAMURKAS, T
    DEALY, JM
    POLYMER ENGINEERING AND SCIENCE, 1989, 29 (08): : 499 - 504
  • [8] WALL SLIP OF MOLTEN HIGH-DENSITY POLYETHYLENE .1. SLIDING PLATE RHEOMETER STUDIES
    HATZIKIRIAKOS, SG
    DEALY, JM
    JOURNAL OF RHEOLOGY, 1991, 35 (04) : 497 - 523
  • [9] A SLIDING PLATE NORMAL THRUST RHEOMETER FOR MOLTEN PLASTICS
    OAKLEY, JG
    GIACOMIN, AJ
    POLYMER ENGINEERING AND SCIENCE, 1994, 34 (07): : 580 - 584
  • [10] A high pressure sliding plate rheometer for polymer melts
    Koran, F
    Dealy, JM
    JOURNAL OF RHEOLOGY, 1999, 43 (05) : 1279 - 1290