A Large Lift-Off Nondestructive Testing Method Based on the Interaction Between AC Magnetic Field and MFL Field

被引:1
|
作者
Wang, Rongbiao [1 ]
Deng, Zhiyang [1 ]
Liu, Rui [1 ]
Kang, Yihua [1 ]
Zhang, Jikai [1 ]
Tang, Jian [1 ]
机构
[1] Huazhong Univ Sci & Technol, State Key Lab Digital Mfg Equipment & Technol, Wuhan, Peoples R China
来源
ELECTROMAGNETIC NONDESTRUCTIVE EVALUATION XXII | 2019年 / 44卷
关键词
Large lift-off; Eddy Current Probes; MFL; EDDY-CURRENT;
D O I
10.3233/SAEM190009
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The magnetic leakage field of the crack gets weaker rapidly as the lift-off value increases, which makes the detection more difficult, especially for many insulated pipes. On the other hand, for eddy current testing, the AC magnetic flux of the excitation coil decreases exponentially with respect to the probe lift-off value, meanwhile, the surface eddy current density decreases rapidly according to the law of electromagnetic induction. To achieve the inspection in a large lift-off, a large life-off NDT method based on the interaction between AC Magnetic field and MFL field is proposed. A series of simulations and experiments are conducted to verify its feasibility.
引用
收藏
页码:44 / 49
页数:6
相关论文
共 50 条
  • [1] A method for compensation of permanent magnetic field perturbation (PMFP) testing signal based on lift-off measurement
    Hu, Yu
    Wang, Shenghan
    Duan, Zhaoqi
    Gao, Yiming
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2023, 34 (12)
  • [2] Electromagnetic nondestructive testing at high lift-off using a magnetic image conduit
    Lee, Jinyi
    Jun, Jongwoo
    Kim, Jungmin
    Le, Minhhuy
    JOURNAL OF MECHANICAL SCIENCE AND TECHNOLOGY, 2013, 27 (05) : 1287 - 1293
  • [3] Electromagnetic nondestructive testing at high lift-off using a magnetic image conduit
    Jinyi Lee
    Jongwoo Jun
    Jungmin Kim
    Minhhuy Le
    Journal of Mechanical Science and Technology, 2013, 27 : 1287 - 1293
  • [4] New MFL nondestructive testing method based on magnetic vacuum leakage
    State Key Lab. of Digital Manufacturing Equipment and Technology, Huazhong University of Science and Technology, Wuhan 430074, China
    Jixie Gongcheng Xuebao, 14 (18-23):
  • [5] Online Condition Monitoring of Bonding Wires Lift-Off in Power Modules Based on Magnetic Field Measurement
    Guo, Weili
    Xiao, Guochun
    Wang, Laili
    IEEE TRANSACTIONS ON POWER ELECTRONICS, 2025, 40 (03) : 4425 - 4436
  • [6] A new SNR enhancement method in MFL detection for microcracks on rough surface based on the ferromagnetic lift-off layer
    Yang, Yun
    Qiu, Shaoxiong
    Liang, Zhenyu
    Kang, Yihua
    NONDESTRUCTIVE TESTING AND EVALUATION, 2024,
  • [7] A Novel Electromagnetic Testing Method Based on the Magnetic Field Interaction
    Sun, Yanhua
    Liu, Shiwei
    Jiang, Xiaoyuan
    He, Lingsong
    Gu, Min
    Liu, Changde
    Kang, Yihua
    Luo, Xiaohui
    Xu, Jiang
    IEEE TRANSACTIONS ON MAGNETICS, 2019, 55 (08)
  • [8] The effect of sensor lift-off on crack depth measurement by the Surface Magnetic Field Measurement technique
    Salemi, AH
    Sadeghi, SHH
    Moini, R
    REVIEW OF PROGRESS IN QUANTITATIVE NONDESTRUCTIVE EVALUATION, VOLS 21A & B, 2002, 615 : 977 - 983
  • [9] Thermoelastic stress field investigation of GaN material for laser lift-off technique based on finite element method
    School of Mechatronical Engineering, Beijing Institute of Technology, Beijing 100081, China
    Chin. Phys. Lett., 2009, 9
  • [10] Suppressing sensor lift-off effects on cracks signals in surface magnetic field Measurement technique
    Amineh, RK
    Sadeghi, SHH
    Moini, R
    2003 IEEE INTERNATIONAL CONFERENCE ON INDUSTRIAL TECHNOLOGY, VOLS 1 AND 2, PROCEEDINGS, 2003, : 360 - 363