SyM-BBB: a microfluidic blood brain barrier model

被引:257
|
作者
Prabhakarpandian, Balabhaskar [1 ]
Shen, Ming-Che [1 ]
Nichols, Joseph B. [1 ]
Mills, Ivy R. [1 ]
Sidoryk-Wegrzynowicz, Marta [2 ]
Aschner, Michael [2 ,3 ,4 ]
Pant, Kapil [1 ]
机构
[1] CFD Res Corp, Biomed Technol, Huntsville, AL 35805 USA
[2] Vanderbilt Univ, Med Ctr, Dept Pediat, Nashville, TN 37232 USA
[3] Vanderbilt Univ, Med Ctr, Kennedy Ctr Res Human Dev, Nashville, TN 37232 USA
[4] Vanderbilt Univ, Med Ctr, Dept Pharmacol, Nashville, TN 37232 USA
基金
美国国家卫生研究院;
关键词
MICROVESSEL ENDOTHELIAL-CELLS; IN-VITRO MODEL; RAT-BRAIN; FUNCTIONAL EXPRESSION; TRANSPORT; CULTURE; RBE4; PERMEABILITY; DISEASE;
D O I
10.1039/c2lc41208j
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Current techniques for mimicking the Blood-Brain Barrier (BBB) largely use incubation chambers (Transwell) separated with a filter and matrix coating to represent and to study barrier permeability. These devices have several critical shortcomings: (a) they do not reproduce critical microenvironmental parameters, primarily anatomical size or hemodynamic shear stress, (b) they often do not provide real-time visualization capability, and (c) they require a large amount of consumables. To overcome these limitations, we have developed a microfluidics based Synthetic Microvasculature model of the Blood-Brain Barrier (SyM-BBB). The SyM-BBB platform is comprised of a plastic, disposable and optically clear microfluidic chip with a microcirculation sized two-compartment chamber. The chamber is designed in such a way as to permit the realization of side-by-side apical and basolateral compartments, thereby simplifying fabrication and facilitating integration with standard instrumentation. The individually addressable apical side is seeded with endothelial cells and the basolateral side can support neuronal cells or conditioned media. In the present study, an immortalized Rat Brain Endothelial cell line (RBE4) was cultured in SyM-BBB with a perfusate of Astrocyte Conditioned Media (ACM). Biochemical analysis showed upregulation of tight junction molecules while permeation studies showed an intact BBB. Finally, transporter assay was successfully demonstrated in SyM-BBB indicating a functional model.
引用
收藏
页码:1093 / 1101
页数:9
相关论文
共 50 条
  • [1] Characterization of a microfluidic in vitro model of the blood-brain barrier (μBBB)
    Booth, Ross
    Kim, Hanseup
    LAB ON A CHIP, 2012, 12 (10) : 1784 - 1792
  • [2] Advances in Microfluidic Blood-Brain Barrier (BBB) Models
    Oddo, Arianna
    Peng, Bo
    Tong, Ziqiu
    Wei, Yingkai
    Tong, Wing Yin
    Thissen, Helmut
    Voelcker, Nicolas Hans
    TRENDS IN BIOTECHNOLOGY, 2019, 37 (12) : 1295 - 1314
  • [3] Blood-brain Barrier (BBB): An overview of the research of the blood-brain barrier using microfluidic devices
    Van Der Meer, Andries D.
    Wolbers, Floor
    Vermes, Istvãn
    Van Den Berg, Albert
    RSC Nanoscience and Nanotechnology, 2015, 2015-January (36): : 40 - 56
  • [4] A Microfluidic Blood Brain Barrier Model to Study the Influence of Glioblastoma Tumor Cells on BBB Function
    DePalma, Thomas
    Rodriguez, Marco
    Kollin, Luke
    Hughes, Kennedy
    Jones, Katie
    Stagner, Emerie
    Venere, Monica
    Skardal, Aleksander
    SMALL, 2025,
  • [5] Permeability of an In Vitro Model of Blood Brain Barrier (BBB)
    Amin, Rashid
    Artmann, Temiz A.
    Artmann, Gerhard
    Lazarovici, Philip
    Lelkes, Peter I.
    13TH INTERNATIONAL CONFERENCE ON BIOMEDICAL ENGINEERING, VOLS 1-3, 2009, 23 (1-3): : 81 - +
  • [6] A Microfluidic Model of the Blood Brain Barrier
    Adriani, G.
    Ma, D.
    Pavesi, A.
    Goh, E.
    Kamm, R. D.
    TISSUE ENGINEERING PART A, 2015, 21 : S40 - S40
  • [7] Examination of blood–brain barrier (BBB) integrity in a mouse brain tumor model
    Ngoc H. On
    Ryan Mitchell
    Sanjot D. Savant
    Corbin. J. Bachmeier
    Grant M. Hatch
    Donald W. Miller
    Journal of Neuro-Oncology, 2013, 111 : 133 - 143
  • [8] BBB kit (Blood-Brain barrier in vitro reconstruction model).
    Nakagawa, S.
    Deli, M. A.
    Nakao-Nishioku, S.
    Hayashi, K.
    Nakaoke, R.
    Kataoka, Y.
    Niwa, M.
    CLINICAL AND EXPERIMENTAL HYPERTENSION, 2007, 29 (04) : 235 - 235
  • [9] Characterization of a new in vitro model of the blood-brain barrier (BBB)
    Dolman, DEM
    Anderson, P
    Rollinson, C
    Abbott, NJ
    JOURNAL OF PHYSIOLOGY-LONDON, 1997, 505P : 56P - 57P
  • [10] BBB kit:: Blood-brain-barrier in vitro reconstruction model
    Nakagawa, Shinsuke
    Dell, Maria A.
    Nakao-Nishioku, Shinobu
    Hayashi, Kentaro
    Nakaoke, Ryota
    Kataoka, Yasufumi
    Niwa, Masami
    JOURNAL OF PHARMACOLOGICAL SCIENCES, 2007, 103 : 57P - 57P