Ultra Fast Scanned Electron Beam X-Ray CT for Two-Phase Flow Measurement

被引:0
|
作者
Hampel, Uwe [1 ]
Fischer, Frank [1 ]
Schleicher, Eckhard [1 ]
Hoppe, Dietrich [1 ]
机构
[1] Forsch Zentrum Dresden Rossendorf, Inst Safety Res, D-01314 Dresden, Germany
来源
关键词
Electron beam CT; X-ray CT; multiphase flow imaging;
D O I
暂无
中图分类号
O59 [应用物理学];
学科分类号
摘要
We developed ail ultra fast X-ray CT seamier based on scanned electron beam technology. The new device enables ultra fast two-dimensional phase fraction imaging in flow cross-sections at frame rates Lip to 7 KHz. As an example flow measurement in a 60 mm diameter bubble column is presented.
引用
收藏
页码:144 / 150
页数:7
相关论文
共 50 条
  • [1] Ultra Fast Electron Beam X-Ray Ct Scanner for Two-Phase Flow Measurement
    Fischer, Frank
    Hampel, Uwe
    ATW-INTERNATIONAL JOURNAL FOR NUCLEAR POWER, 2009, 54 (07): : 461 - +
  • [2] Ultra fast electron beam X-ray computed tomography for two-phase flow measurement
    Fischer, F.
    Hampel, U.
    NUCLEAR ENGINEERING AND DESIGN, 2010, 240 (09) : 2254 - 2259
  • [3] Evaluation of a limited angle scanned electron beam x-ray CT approach for two-phase pipe flows
    Bieberle, M.
    Hampel, U.
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2006, 17 (08) : 2057 - 2065
  • [4] Experimental two-phase flow measurement using ultra fast limited-angle-type electron beam X-ray computed tomography
    M. Bieberle
    F. Fischer
    E. Schleicher
    D. Koch
    H.-J. Menz
    H.-G. Mayer
    U. Hampel
    Experiments in Fluids, 2009, 47
  • [5] Experimental two-phase flow measurement using ultra fast limited-angle-type electron beam X-ray computed tomography
    Bieberle, M.
    Fischer, F.
    Schleicher, E.
    Koch, D.
    Menz, H. -J.
    Mayer, H. -G.
    Hampel, U.
    EXPERIMENTS IN FLUIDS, 2009, 47 (03) : 369 - 378
  • [6] Simulation study on electron beam x-ray CT arrangements for two-phase flow measurements
    Bieberle, M.
    Schleicher, E.
    Hampel, U.
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2008, 19 (09)
  • [7] Ultra Fast Electron Beam X-Ray Tomography and its Application to Multiphase Flow Measurement
    Hampel, Uwe
    Fischer, Frank
    2008 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (2008 NSS/MIC), VOLS 1-9, 2009, : 5464 - 5468
  • [8] Experimental ultra fast X-ray computed tomography with a linearly scanned electron beam source
    Hampel, U
    Speck, M
    Koch, D
    Menz, HJ
    Mayer, HG
    Fietz, J
    Hoppe, D
    Schleicher, E
    Zippe, C
    Prasser, HM
    FLOW MEASUREMENT AND INSTRUMENTATION, 2005, 16 (2-3) : 65 - 72
  • [9] A compact x-ray system for two-phase flow measurement
    Song, Kyle
    Liu, Yang
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2018, 29 (02)
  • [10] An ultra fast electron beam x-ray tomography scanner
    Fischer, F.
    Hoppe, D.
    Schleicher, E.
    Mattausch, G.
    Flaske, H.
    Bartel, R.
    Hampel, U.
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2008, 19 (09)