Feedback Control of a Rotary Left Ventricular Assist Device Supporting a failing Cardiovascular System

被引:0
|
作者
Wang, Yu [1 ]
Faragallah, George [1 ]
Divo, Eduardo [2 ]
Simaan, Marwan A. [1 ]
机构
[1] Univ Cent Florida, Dept Elect Engn & Comp Sci, Orlando, FL 32816 USA
[2] Daytona State Coll, Sch Engn Technol, Daytona Beach, FL 32117 USA
关键词
D O I
暂无
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
A new feedback control system for a current-based model of the combined cardiovascular system and a rotary left ventricular assist device is presented. The system consists of a suction detection subsystem and a feedback controller subsystem. The suction detection subsystem is based on a Lagrangian Support Vector Machine model. In the absence of suction in the left ventricle, as indicated by the suction detection subsystem, the proposed feedback controller automatically adjusts the pump motor current in order to meet the blood flow requirement of the patient's body at different physiological states. The performance of the feedback control system has been tested to show the ability to autonomously adjust the pump current, while sustaining required cardiac output and mean arterial pressure. Simulation results show that the controller can keep cardiac output and mean arterial pressure within acceptable physiologic ranges under different conditions of the patient activities. Robustness to noise of the controller is also discussed.
引用
收藏
页码:1137 / 1142
页数:6
相关论文
共 50 条
  • [1] Physiological control of rotary left ventricular assist device
    Yi, Wu
    PROCEEDINGS OF THE 26TH CHINESE CONTROL CONFERENCE, VOL 6, 2007, : 469 - 474
  • [2] Modelling and control of a failing heart managed by a left ventricular assist device
    Son, Jeongeun
    Du, Dongping
    Du, Yuncheng
    BIOCYBERNETICS AND BIOMEDICAL ENGINEERING, 2020, 40 (01) : 559 - 573
  • [3] Control Method of a Rotary Blood Pump for a Left Ventricular Assist Device
    Petukhov, D. S.
    Telyshev, D. V.
    Selishchev, S. V.
    SOVREMENNYE TEHNOLOGII V MEDICINE, 2016, 8 (01) : 28 - 33
  • [4] A New Current-Based Control Model of the Combined Cardiovascular and Rotary Left Ventricular Assist Device
    Faragallah, George
    Wang, Yu
    Divo, Eduardo
    Simaan, Marwan A.
    2011 AMERICAN CONTROL CONFERENCE, 2011, : 4775 - 4780
  • [5] Numeric modeling of the cardiovascular system with a left ventricular assist device
    Zhou, JH
    Armstrong, GP
    Medvedev, AL
    Smith, WA
    Golding, LAR
    Thomas, JD
    ASAIO JOURNAL, 1999, 45 (01) : 83 - 89
  • [6] Feedback control of an LVAD supporting a failing cardiovascular system regulated by the Baroreflex
    Chen, Shaohui
    Ferreira, Antonio
    Simaan, Marwan A.
    Boston, J. Robert
    Antaki, James F.
    PROCEEDINGS OF THE 45TH IEEE CONFERENCE ON DECISION AND CONTROL, VOLS 1-14, 2006, : 658 - +
  • [7] Modeling, estimation and control of cardiovascular systems with a left ventricular assist device
    Wu, Y
    Allaire, P
    Tao, G
    Olsen, D
    ACC: PROCEEDINGS OF THE 2005 AMERICAN CONTROL CONFERENCE, VOLS 1-7, 2005, : 3841 - 3846
  • [8] Left ventricular assist device - unexpected benefits for the failing heart
    Pasierski, Tomasz
    Buksinska-Lisik, Malgorzata
    KARDIOLOGIA POLSKA, 2008, 66 (06) : 678 - 683
  • [9] Numerical simulation of the influence of a left ventricular assist device on the cardiovascular system
    Verkerke, GJ
    Geertsema, AA
    Mihaylov, D
    Blanksma, PK
    Rakhorst, G
    INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 2000, 23 (11): : 765 - 773
  • [10] Modeling of a new sensorless suction detection system for the rotary left ventricular assist device
    Peng, Jing
    Lu, Anhua
    Wang, Yu
    2018 NINTH INTERNATIONAL CONFERENCE ON INFORMATION TECHNOLOGY IN MEDICINE AND EDUCATION (ITME 2018), 2018, : 247 - 251