Reconstruction of Dual Isotope PET Using Expectation Maximization (EM) Algorithm

被引:0
|
作者
Sitek, Arkadiusz [1 ]
Andreyev, Andriy [1 ,2 ]
Celler, Anna [2 ]
机构
[1] Brigham 7 Womens Hosp, Sch Med Harvard, Dept Radiol, Boston, MA 02115 USA
[2] Univ British Columbia, Coastal Hlth Res Inst, Vancouver, BC V5Z 1M9, Canada
关键词
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The dual-isotope (DI) imaging with positron emission tomography (PET) is particularly difficult because positron-electron annihilation always results in 511 keV photons, irrespective of the radioisotope. Therefore, differentiation of PET isotopes based on the energy discrimination is impossible. However, there are radioisotopes that in addition to a positron also emit at least one prompt high energy (HE) gamma (positron-gamma emitters). The detection of this gamma in coincidence with two annihilation photons tags this particular PET event as originating from the decay of the isotope with positron-gamma emissions. An example of such radioisotope is Cu-60 which can be used ID our approach for DI studies together with a pure positron emitter F-18. Two data sets are acquired in DI-PET imaging. The first, standard PET dataset results from detections of two coincident 511 keV photons, and the second dataset - from detection of two 511 keV photons in coincidence with a HE gamma. The challenge is then to reconstruct two separate activities using the information contained in these two datasets. In this work, we developed an Expectation Maximization (EM) algorithm for the estimation of distributions of both isotopes. The EM update equations were derived and evaluated using synthetic data. We used Monte Carlo package GATE to simulate the dual-isotope acquisition with a standard PET camera. Realistic efficiencies were assumed for the HE gamma detection varying from 3% to 9%. A set of seven partially overlapping 3D objects filled with F-18 and Cu-60 was located at the center of a water phantom of 30 cm diameter. A low-count (250k decays of each F-18 and Cu-60) and a high-count (2.5M decays each) acquisitions were simulated. We found that the dual-isotope EM algorithm was able to successfully separate two PET tracers for all values of studied parameters. As expected the accuracy of this separation increased for higher HE gamma detection efficiency and higher total number of detected counts. A systematic analysis of the quantitative accuracy of these reconstructions is currently being performed.
引用
收藏
页码:4323 / 4326
页数:4
相关论文
共 50 条
  • [1] Visualization of Dengue Incidences using Expectation Maximization (EM) Algorithm
    Mathur, Nirbhay
    Asirvadam, Vijanth S.
    Dass, Sarat C.
    Gill, Balvinder Singh
    2016 6TH INTERNATIONAL CONFERENCE ON INTELLIGENT AND ADVANCED SYSTEMS (ICIAS), 2016,
  • [2] The Expectation-Maximization Algorithm: Gaussian Case The EM Algorithm
    Iatan, Iuliana F.
    2010 INTERNATIONAL CONFERENCE ON NETWORKING AND INFORMATION TECHNOLOGY (ICNIT 2010), 2010, : 590 - 593
  • [3] EM reconstruction of dual isotope PET using staggered injections and prompt gamma positron emitters
    Andreyev, Andriy
    Sitek, Arkadiusz
    Celler, Anna
    MEDICAL PHYSICS, 2014, 41 (02)
  • [4] An investigation of convergence rates in expectation maximization (EM) iterative reconstruction
    Liu, Z
    Obi, T
    Yamaguchi, M
    Ohyama, N
    1999 IEEE NUCLEAR SCIENCE SYMPOSIUM - CONFERENCE RECORD, VOLS 1-3, 1999, : 1412 - 1417
  • [5] TRLFS: Analysing spectra with an expectation-maximization (EM) algorithm
    Steinborn, A.
    Taut, S.
    Brendler, V.
    Geipel, G.
    Flach, B.
    SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY, 2008, 71 (04) : 1425 - 1432
  • [6] GENERAL CONVERGENT EXPECTATION MAXIMIZATION (EM)-TYPE ALGORITHMS FOR IMAGE RECONSTRUCTION
    Yan, Ming
    Bui, Alex A. T.
    Cong, Jason
    Vese, Luminita A.
    INVERSE PROBLEMS AND IMAGING, 2013, 7 (03) : 1007 - 1029
  • [7] Wavelet based Multiresolution Expectation Maximization image reconstruction algorithm for Positron Emission Tomography (PET)
    Raheja, A
    Dhawan, AP
    MEDICAL IMAGING 1999: IMAGE PROCESSING, PTS 1 AND 2, 1999, 3661 : 385 - 396
  • [8] Expectation maximization (EM) algorithms using polar symmetries for computed tomography (CT) image reconstruction
    Rodriguez-Alvarez, M. J.
    Soriano, A.
    Iborra, A.
    Sanchez, F.
    Gonzalez, A. J.
    Conde, P.
    Hernandez, L.
    Moliner, L.
    Orero, A.
    Vidal, L. F.
    Benlloch, J. M.
    COMPUTERS IN BIOLOGY AND MEDICINE, 2013, 43 (08) : 1053 - 1061
  • [9] Multiplexing Kernelized Expectation Maximization Reconstruction for PET-MR
    Deidda, Daniel
    Aykroyd, Robert G.
    Tsoumpas, Charalampos
    2018 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE PROCEEDINGS (NSS/MIC), 2018,
  • [10] EM Reconstruction of Dual Isotope PET with Staggered Injections and Prompt Gamma Positron Emitters
    Andreyev, Andriy
    Sitek, Arkadiusz
    Celler, Anna
    2012 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE RECORD (NSS/MIC), 2012, : 3701 - 3706