Comparison of Broad-band and Hyperspectral Thermal Infrared Imaging of Buried Threat Objects

被引:2
|
作者
McFee, John E. [1 ]
Achal, Stephen B.
Diaz, Alejandra U.
Faust, Anthony A. [1 ]
机构
[1] Def R&D Canada Suffield, Stn Main, Medicine Hat, AB T1A 8K6, Canada
关键词
landmine; improvised explosive devices; detection; hyperspectral imaging; thermal infrared; broad-band;
D O I
10.1117/12.2016790
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Previous research by many groups has shown that broad-band thermal infrared (TIR) imagers can detect buried explosive threat devices, such as unexploded ordnance (UXO), landmines and improvised explosive devices (IEDs). Broad-band detection measures the apparent temperature - an average over the wave band of the product of the true soil surface temperature and the emissivity. Broad-band detection suffers from inconsistent performance (low signal, high clutter rates), due in part to diurnal variations, environmental and meteorological conditions, and soil surface effects. It has been suggested that hyperspectral TIR imaging might have improved performance since it can, in principle, allow extraction of the wavelength-dependent emissivity and the true soil surface temperature. This would allow the surface disturbance effects to be separated from the soil column (bulk) effects. A significant, and as yet unanswered, question is whether hyperspectral TIR images provide better detection capability (higher probability of detection and/or lower false alarm rate) than do broad-band thermal images. TIR hyperspectral image data of threat objects, buried and surface-laid in bare soil, were obtained in arid, desert-like conditions over full diurnal cycles for several days. Regions of interest containing threat objects and backgrounds were extracted throughout the time period. Simulated broad-band images were derived from the hyperspectral images. The diurnal variation of the images was studied. Hyperspectral was found to provide some advantage over broad-band imaging in detection of buried threat objects for the limited data set studied.
引用
收藏
页数:13
相关论文
共 50 条
  • [1] Airborne Thermal Infrared Hyperspectral Imaging of Buried Objects
    Gagnon, Marc-Andre
    Lagueux, Philippe
    Gagnon, Jean-Philippe
    Savary, Simon
    Tremblay, Pierre
    Farley, Vincent
    Guyot, Eric
    Chamberland, Martin
    DETECTION AND SENSING OF MINES, EXPLOSIVE OBJECTS, AND OBSCURED TARGETS XX, 2015, 9454
  • [2] Airborne Thermal Infrared Hyperspectral Imaging of Buried Objects
    Gagnon, Marc-Andre
    Lagueux, Philippe
    Gagnon, Jean-Philippe
    Savary, Simon
    Tremblay, Pierre
    Farley, Vincent
    Guyot, Eric
    Chamberland, Martin
    ELECTRO-OPTICAL REMOTE SENSING, PHOTONIC TECHNOLOGIES, AND APPLICATIONS IX, 2015, 9649
  • [3] BROAD-BAND INFRARED THERMAL DETECTOR
    SHAULOV, A
    SENSORS AND ACTUATORS, 1984, 5 (03): : 207 - 215
  • [4] COMPARISON OF BROAD-BAND AND HIGH-SPECTRAL-RESOLUTION INFRARED OBSERVATIONS
    ACKERMAN, SA
    SMITH, WL
    REVERCOMB, HE
    INTERNATIONAL JOURNAL OF REMOTE SENSING, 1993, 14 (15) : 2875 - 2882
  • [5] HIGHLY BROAD-BAND BURIED-CHANNEL COUPLERS
    LOVE, JD
    STEBLINA, VV
    ELECTRONICS LETTERS, 1994, 30 (22) : 1853 - 1855
  • [6] BROAD-BAND IMAGING WITH HOLOGRAPHIC LENSES
    FAKLIS, D
    MORRIS, GM
    OPTICAL ENGINEERING, 1989, 28 (06) : 592 - 598
  • [7] BROAD-BAND THERMAL OPTICAL LIMITER
    JUSTUS, BL
    HUSTON, AL
    CAMPILLO, AJ
    APPLIED PHYSICS LETTERS, 1993, 63 (11) : 1483 - 1485
  • [8] AN EXPERIMENTAL BROAD-BAND IMAGING FEED
    CHU, TS
    ENGLAND, RW
    BELL SYSTEM TECHNICAL JOURNAL, 1983, 62 (05): : 1233 - 1250
  • [9] PRINCIPLES OF BROAD-BAND COHERENT IMAGING
    FARHAT, NH
    JOURNAL OF THE OPTICAL SOCIETY OF AMERICA, 1977, 67 (08) : 1015 - 1021
  • [10] BROAD-BAND TUNING IN AN INFRARED PARAMETRIC OSCILLATOR
    BHAR, GC
    GHOSH, NP
    PHYSICA STATUS SOLIDI A-APPLIED RESEARCH, 1988, 106 (01): : K93 - K96