The effects of partial shear connection in composite flush end plate joints - Part I - experimental study

被引:97
|
作者
Loh, HY
Uy, B [1 ]
Bradford, MA
机构
[1] Univ New S Wales, Sch Civil & Environm Engn, Sydney, NSW 2052, Australia
[2] Univ Wollongong, Sch Civil Min & Environm Engn, Wollongong, NSW 2522, Australia
基金
澳大利亚研究理事会;
关键词
composite connections; partial shear connection; flush end plate; blind bolting;
D O I
10.1016/j.jcsr.2005.07.012
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The experimental results of partial shear connection composite beams subjected to hogging bending have been previously reported. An extension to this work which considers the presence of a semi-rigid, partial strength connection is described herein. Five sub-assemblages of cruciform composite joints that simulate the internal region of a semi-continuous frame were tested. The joints were constructed using a novel approach of blind bolting a flush end plate to concrete-filled square hollow columns. Apart from the level of shear connection, the other parameter varied was the reinforcement area. In addition, a bare steel joint was also tested to act as comparison specimen. Based on the experimental results, the intrinsic behaviour of the joints in terms of strength, stiffness and ductility was assessed. It was further affirmed that by lowering the levels of shear connection, the rotation capacity of the composite joints was enhanced with only a slight compromise if the stiffness and moment resistance. A notable effect on the connection behaviour was also observed by varying the reinforcement levels. The outcomes clearly affirmed the benefits of partial shear connection in contributing the additional flexibility to increase the joint ductility, which is extremely advantageous for plastic design purposes. In view of this, the current restriction of providing full shear connection design within hogging moment regions of continuous and semi-continuous structures could be relaxed. (c) 2005 Elsevier Ltd. All rights reserved.
引用
收藏
页码:378 / 390
页数:13
相关论文
共 50 条
  • [1] The effects of partial shear connection in composite flush end plate joints - Part II - Analytical study and design appraisal
    Loh, HY
    Uy, B
    Bradford, MA
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2006, 62 (04) : 391 - 412
  • [2] Experimental Study of Composite Steel Plate Shear Wall with Flush End-Plate Connection
    Jin-Guang Yu
    Xiao-Tian Feng
    Ji-Ping Hao
    Xi Gao
    International Journal of Steel Structures, 2020, 20 : 136 - 155
  • [3] Experimental Study of Composite Steel Plate Shear Wall with Flush End-Plate Connection
    Yu, JinGuang
    Feng, Xiao-Tian
    Hao, Ji-Ping
    Gao, Xi
    INTERNATIONAL JOURNAL OF STEEL STRUCTURES, 2020, 20 (01) : 136 - 155
  • [4] The effects of partial shear connection in the hogging moment regions of composite beams - Part I - Experimental study
    Loh, HY
    Uy, B
    Bradford, MA
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2004, 60 (06) : 897 - 919
  • [5] Experimental study on flush end-plate composite joints under positive moment
    Hu, Xia-Min
    Li, Xuan
    Dong, Shuo
    Harbin Gongye Daxue Xuebao/Journal of Harbin Institute of Technology, 2007, 39 (SUPPL. 2): : 397 - 401
  • [6] Experimental study of flush end plate beam-to-CFST column composite joints with deconstructable bolted shear connectors
    Ataei, Abdolreza
    Bradford, Mark A.
    Valipour, Hamid R.
    ENGINEERING STRUCTURES, 2015, 99 : 616 - 630
  • [7] Experimental study of flush end plate beam-to-column composite joints with precast slabs and deconstructable bolted shear connectors
    Ataei, Abdolreza
    Bradford, Mark A.
    Liu, Xinpei
    STRUCTURES, 2016, 7 : 43 - 58
  • [8] Experimental investigation on flush end-plate bolted composite connection in fire
    Li, Jiao-Ting
    Li, Guo-Qiang
    Lou, Guo-Biao
    Chen, Ling-zhu
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2012, 76 : 121 - 132
  • [9] Experimental study on seismic performance of flush end plate connections of steel-concrete composite joints
    Zhang J.
    Hu X.
    Du H.
    Sun Q.
    Li L.
    Zheng D.
    Jianzhu Jiegou Xuebao/Journal of Building Structures, 2019, 40 : 109 - 117
  • [10] Experimental study of sustainable high strength steel flush end plate beam-to-column composite joints with deconstructable bolted shear connectors
    Ataei, Abdolreza
    Bradford, Mark A.
    Valipour, Hamid R.
    Liu, Xinpei
    ENGINEERING STRUCTURES, 2016, 123 : 124 - 140