This paper compares solid-phase microextraction (SPME) with a recently developed extraction method called single-drop microextraction (SDME) for the analysis of nitroaromatic explosives in water samples. The two techniques are examined in terms of procedure, chromatographic analysis and method performance. All practical considerations for both techniques are also reviewed. SPME requires dedicated apparatus and is relatively expensive, as the fiber's lifetime is limited. However, it has the advantages over SDME that it can be easily used for headspace analysis and has lower detection limits for all the target analytes. SDME requires more elaborate manual operations, thus affecting linearity and precision. (C) 2001 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:113 / 120
页数:8
相关论文
共 50 条
  • [1] Single-drop extraction versus solid-phase microextraction for the analysis of VOCs in water
    Buszewski, B
    Ligor, T
    LC GC EUROPE, 2002, 15 (02) : 92 - +
  • [2] Headspace single-drop microextraction for the analysis of chlorobenzenes in water samples
    Vidal, L
    Canals, A
    Kalogerakis, N
    Psillakis, E
    JOURNAL OF CHROMATOGRAPHY A, 2005, 1089 (1-2) : 25 - 30
  • [3] Application of single-drop microextraction and comparison with solid-phase microextraction and solid-phase extraction for the determination of α- and β-endosulfan in water samples by gas chromatography-electron-capture detection
    López-Blanco, MC
    Blanco-Cid, S
    Cancho-Grande, B
    Simal-Gándara, J
    JOURNAL OF CHROMATOGRAPHY A, 2003, 984 (02) : 245 - 252
  • [4] Application of solvent microextraction to the analysis of nitroaromatic explosives in water samples
    Psillakis, E
    Kalogerakis, N
    JOURNAL OF CHROMATOGRAPHY A, 2001, 907 (1-2) : 211 - 219
  • [5] Single-drop microextraction for the determination of manganese in seafood and water samples
    Lemos, Valfredo Azevedo
    Vieira, Uelber Silva
    MICROCHIMICA ACTA, 2013, 180 (5-6) : 501 - 507
  • [6] Single-drop microextraction for the determination of manganese in seafood and water samples
    Valfredo Azevedo Lemos
    Uelber Silva Vieira
    Microchimica Acta, 2013, 180 : 501 - 507
  • [7] Use of single-drop microextraction for determination of fentanyl in water samples
    Gupta, Pradeep Kumar
    Manral, Laxmi
    Ganesan, Kumaran
    Dubey, Devendra Kumar
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2007, 388 (03) : 579 - 583
  • [8] Use of single-drop microextraction for determination of fentanyl in water samples
    Pradeep Kumar Gupta
    Laxmi Manral
    Kumaran Ganesan
    Devendra Kumar Dubey
    Analytical and Bioanalytical Chemistry, 2007, 388 : 579 - 583
  • [9] Single-drop microextraction
    Tang, Sheng
    Qi, Tong
    Ansah, Prince Dim
    Fouemina, Juliette Chancellevie Nalouzebi
    Shen, Wei
    Basheer, Chanbasha
    Lee, Hian Kee
    TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2018, 108 : 306 - 313
  • [10] Single-drop microextraction for the analysis of organophosphorous insecticides in water
    Lambropoulou, DA
    Psillakis, E
    Albanis, TA
    Kalogerakis, N
    ANALYTICA CHIMICA ACTA, 2004, 516 (1-2) : 205 - 211