Measurement of photoneutron doses in and out of high-energy X-ray beam of a SATURNE-20 medical linear accelerator by ECE polycarbonate detectors

被引:19
|
作者
Sohrabi, M
Mostofizadeh, A
机构
[1] Atom Energy Org Iran, Natl Radiat Protect Dept, Tehran, Iran
[2] Atom Energy Org Iran, Ctr Res Nat Radiat, Tehran, Iran
关键词
medical accelerator; radiotherapy; high energy X-rays; photoneutrons; neutron dose; measurements; polycarbonate dosimeters; electrochemical etching;
D O I
10.1016/S1350-4487(99)00203-6
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
Photoneutron contaminations in and out of high energy X-ray beams of the medical linear accelerator SATURNE 20 (CGR) of the Radiotherapy Department of Omeed Hospital in Isfahan, Iran, have been determined using 250 mu m polycarbonate (PC) dosimeters, in strips or in sheets, processed by electrochemical etching (ECE) using specially designed ECE chambers to etch larger sheets. A two dimensional or topographical distribution of neutron contamination was also determined in a full size beam. The neutron dose equivalents (Hn) in the beam of 18 MV X-rays at 80 cm FSD were determined to be linear functions of Xray dose equivalents (Hx) up to 1400 cSv. The distribution of the Hn at different X-ray doses showed bell-shape profiles with maxima at the isocenter. The ratios of dose equivalents of neutrons to those of X-rays increased as the field size increased having values of 0.22%, 0.28%, 0.31% and 0.37% for field sizes of 10x10, 20x20, 30x30, and 40x40 cm(2) respectively. Although such neutron dose equivalents can be corrected for patient treatment, it can cause radiation protection problems for workers where the design of the facility is not well planned.
引用
收藏
页码:479 / 482
页数:4
相关论文
共 13 条
  • [1] Measurement of photoneutron doses in and out of high-energy X-ray beam of a saturne-20 medical linear accelerator by ECE polycarbonate detectors
    Sohrabi, M.
    Mostofizadeh, A.
    Radiation Measurements, 1999, 31 (01): : 479 - 482
  • [3] PHOTONEUTRON PRODUCTION IN DETECTORS IN HIGH-ENERGY X-RAY BEAMS
    KUSHELEVSKY, AP
    SHANI, G
    NUCLEAR INSTRUMENTS & METHODS, 1976, 137 (01): : 71 - 73
  • [4] Fast, epithermal and thermal photoneutron dosimetry in air and in tissue equivalent phantom for a high-energy X-ray medical accelerator
    Sohrabi, Mehdi
    Hakimi, Amir
    ZEITSCHRIFT FUR MEDIZINISCHE PHYSIK, 2018, 28 (01): : 49 - 62
  • [5] High energy X-ray photon counting imaging using linear accelerator and silicon strip detectors
    Tian, Y.
    Shimazoe, K.
    Yan, X.
    Ueda, O.
    Ishikura, T.
    Fujiwara, T.
    Uesaka, M.
    Ohno, M.
    Tomita, H.
    Yoshihara, Y.
    Takahashi, H.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2016, 830 : 251 - 255
  • [6] Photoneutron depth dose equivalent distributions in high-energy X-ray medical accelerators by a novel position-sensitive dosimeter
    Hakimi, Amir
    Sohrabi, Mehdi
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2017, 36 : 73 - 80
  • [7] MEASUREMENT OF CROSS SECTION OF A HIGH-ENERGY ELECTRON BEAM BY MEANS OF X-RAY PORTION OF SYNCHROTRON RADIATION
    HOFMANN, A
    ROBINSON, KW
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1971, NS18 (03) : 937 - &
  • [8] High-pressure pair distribution function (PDF) measurement using high-energy focused X-ray beam
    Hong, Xinguo
    Ehm, Lars
    Zhong, Zhong
    Ghose, Sanjit
    Duffy, Thomas S.
    Weidner, Donald J.
    PROCEEDINGS OF THE 12TH INTERNATIONAL CONFERENCE ON SYNCHROTRON RADIATION INSTRUMENTATION (SRI2015), 2016, 1741
  • [9] MEASUREMENT OF CROSS-SECTION OF A HIGH-ENERGY ELECTRON BEAM BY MEANS OF X-RAY PORTION OF SYNCHROTRON RADIATION
    HOFMANN, A
    ROBINSON, K
    BULLETIN OF THE AMERICAN PHYSICAL SOCIETY, 1971, 16 (02): : 264 - &