Characterization of a hyper-viscoelastic phantom mimicking biological soft tissue using an abdominal pneumatic driver with magnetic resonance elastography (MRE)

被引:36
|
作者
Leclerc, Gwladys E.
Debernard, Laetitia
Foucart, Felix [2 ]
Robert, Ludovic [3 ]
Pelletier, Kay M. [4 ]
Charleux, Fabrice [3 ]
Ehman, Richard [4 ]
Tho, Marie-Christine Ho Ba
Bensamoun, Sabine F. [1 ]
机构
[1] Univ Technol Compiegne, Ctr Rech Royallieu, CNRS, Lab BioMecan & BioIngn,UMR 7338, F-60206 Compiegne, France
[2] Univ Technol Compiegne, CNRS, UMR 6253, Lab Roberval, F-60206 Compiegne, France
[3] ACRIM Polyclin St Come, Compiegne, France
[4] Mayo Clin, Coll Med, Dept Radiol, Rochester, MN USA
关键词
Multifrequency magnetic resonance; elastography; Viscoelasticity; Hyperelasticity; Phantom; Abdominal pneumatic driver; LIVER VISCOELASTICITY; HEPATIC-FIBROSIS; ORGANS; BRAIN;
D O I
10.1016/j.jbiomech.2012.01.017
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
The purpose of this study was to create a polymer phantom mimicking the mechanical properties of soft tissues using experimental tests and rheological models. Multifrequency Magnetic Resonance Elastography (MMRE) tests were performed on the present phantom with a pneumatic driver to characterize the viscoelastic (mu, eta) properties using Voigt, Maxwell, Zener and Springpot models. To optimize the MMRE protocol, the driver behavior was analyzed with a vibrometer. Moreover, the hyperelastic properties of the phantom were determined using compressive tests and Mooney-Rivlin model. The range of frequency to be used with the round driver was found between 60 Hz and 100 Hz as it exhibits one type of vibration mode for the membrane. MRE analysis revealed an increase in the shear modulus with frequency reflecting the viscoelastic properties of the phantom showing similar characteristic of soft tissues. Rheological results demonstrated that Springpot model better revealed the viscoelastic properties (mu = 3.45 kPa, eta = 6.17 Pas) of the phantom and the Mooney-Rivlin coefficients were C-10 =1.09.10(-2) MPa and C-01 = -8.96.10(-3) MPa corresponding to mu = 3.95 kPa. These studies suggest that the phantom, mimicking soft tissue, could be used for preliminary MRE tests to identify the optimal parameters necessary for in vivo investigations. Further developments of the phantom may allow clinicians to more accurately mimic healthy and pathological soft tissues using MRE. (c) 2012 Elsevier Ltd. All rights reserved.
引用
收藏
页码:952 / 957
页数:6
相关论文
共 17 条
  • [1] Viscoelastic Characterization of Soft Tissue-Mimicking Gelatin Phantoms using Indentation and Magnetic Resonance Elastography
    Feng, Yuan
    Qiu, Suhao
    Chen, Yu
    Wang, Runke
    He, Zhao
    Kong, Linghan
    Chen, Yi
    Ma, Shengyuan
    JOVE-JOURNAL OF VISUALIZED EXPERIMENTS, 2022, (183):
  • [2] Ultrasound-based transient elastography compared to magnetic resonance elastography in soft tissue-mimicking gels
    Oudry, Jennifer
    Vappou, Jonathan
    Choquet, Philippe
    Willinger, Remy
    Sandrin, Laurent
    Constantinesco, Andre
    PHYSICS IN MEDICINE AND BIOLOGY, 2009, 54 (22): : 6979 - 6990
  • [3] Tissue characterization using magnetic resonance elastography: preliminary results
    Kruse, SA
    Smith, JA
    Lawrence, AJ
    Dresner, MA
    Manduca, A
    Greenleaf, JF
    Ehman, RL
    PHYSICS IN MEDICINE AND BIOLOGY, 2000, 45 (06): : 1579 - 1590
  • [4] Development and characterization of a tissue mimicking psyllium husk gelatin phantom for ultrasound and magnetic resonance imaging
    Hofstetter, Lorne W.
    Fausett, Lewis
    Mueller, Alexander
    Odeen, Henrik
    Payne, Allison
    Christensen, Douglas A.
    Parker, Dennis L.
    INTERNATIONAL JOURNAL OF HYPERTHERMIA, 2020, 37 (01) : 283 - 290
  • [5] Phantom Characterization Using the Mechanical Resonance of a Tissue Embedded Magnetic Sphere
    Ersepke, Thomas
    Kranemann, Tim C.
    Schmitz, Georg
    2016 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2016,
  • [6] Anisotropic polyvinyl alcohol hydrogel phantom for shear wave elastography in fibrous biological soft tissue: a multimodality characterization
    Chatelin, Simon
    Bernal, Miguel
    Deffieux, Thomas
    Papadacci, Clement
    Flaud, Patrice
    Nahas, Amir
    Boccara, Claude
    Gennisson, Jean-Luc
    Tanter, Mickael
    Pernot, Mathieu
    PHYSICS IN MEDICINE AND BIOLOGY, 2014, 59 (22): : 6923 - 6940
  • [7] Advances in Imaging of Radiation Therapy Response in Soft Tissue Sarcomas Using Magnetic Resonance Elastography (MRE) and Dynamic Contrast-Enhanced (DCE)-MRI
    Pepin, K.
    Grimm, R.
    Kargar, S.
    Howe, M.
    Fritchie, K.
    Laack, N.
    Herman, M.
    Pafundi, D.
    MEDICAL PHYSICS, 2018, 45 (06) : E538 - E538
  • [8] Determination of in-vivo elastic properties of soft tissue using magnetic resonance elastography
    Kennedy, FE
    Doyley, MM
    Van Houten, EEW
    Weaver, JB
    Paulsen, KD
    2003 ADVANCES IN BIOENGINEERING, 2003, : 327 - 328
  • [9] Anisotropic composite material phantom to improve skeletal muscle characterization using magnetic resonance elastography
    Guidetti, Martina
    Lorgna, Gloria
    Klatt, Dieter
    Vena, Pasquale
    Royston, Thomas J.
    JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2019, 89 : 199 - 208
  • [10] Estimation of elasticity map of soft biological tissue mimicking phantom using laser speckle contrast analysis
    Singh, M. Suheshkumar
    Rajan, K.
    Vasu, R. M.
    JOURNAL OF APPLIED PHYSICS, 2011, 109 (10)