Objective Assessment of Functional Ambulation in Adults with Hemiplegia using Ankle Foot Orthotics after Stroke

被引:30
|
作者
Nolan, Karen J. [1 ,2 ]
Savalia, Krupa K. [1 ]
Lequerica, Anthony H. [1 ,2 ]
Elovic, Elie P. [1 ,2 ,3 ]
机构
[1] Kessler Fdn Res Ctr, W Orange, NJ 07052 USA
[2] UMDNJ New Jersey Med Sch, Dept Phys Med & Rehabil, Newark, NJ USA
[3] Univ Utah, Sch Med, Div Phys Med & Rehabil, Salt Lake City, UT USA
关键词
D O I
10.1016/j.pmrj.2009.04.011
中图分类号
R49 [康复医学];
学科分类号
100215 ;
摘要
Objective: To objectively evaluate the effect of ankle foot orthotics (AFOs) on functional ambulation in individuals with hemiplegia secondary to stroke using quantifiable outcome measures. Design: With-without repeated measures design. Setting: Rehabilitation research center. Participants: Eighteen adults with stroke-related hemiplegia 6 months using a prescribed AFO. Interventions: Not applicable. Main Outcome Measurements: The distance (m) and velocity (m/s) during the 6-Minute Walk Test (6MWT) and total time (s) and velocity (m/s) during the 25-ft walk (25ftW). Secondary analysis evaluated the 6MWT and 25ftW grouped by the time component of the Ambulatory Index (AI). Results: Distance walked during the 6MWT was significantly greater with AFO (228.54 +/- 103.93) than without AFO (197.49 +/- 104.13), P = .002. Time to complete the 25ftW was significantly greater without AFO (21.22 +/- 20.57) than with AFO (15.49 +/- 14.65), P = .010. There was a significant difference in average velocity between the 25ftW and 6MWT during the with AFO condition, P = .010. Secondary analysis grouped by the AI time showed that as level of function decreases, brace effect on functional ambulation increases (Group 3: 25ftW with AFO, P = .040). Conclusions: AFO usage in hemiplegic stroke patients improves functional ambulation, particularly in individuals with a slower gait velocity. The 25ftW, with and without AFO, may be useful to the patient and clinician when determining the importance of brace utilization. Speed modulation was improved when the AFO was added to the paretic limb, and AI grouping indicated that the AFO was more beneficial in people with a slower gait velocity (>20 seconds for the 25ftW). A more definitive study is needed to more completely address this issue. As an exploratory study, the feasibility of different walking assessments was determined so that future studies can validate which objective measures can be used and easily implemented in clinical settings.
引用
收藏
页码:524 / 529
页数:6
相关论文
共 50 条
  • [1] Effect of ankle foot orthosis on gait parameters and functional ambulation in patients with stroke
    Kesikburun, Serdar
    Yavuz, Ferdi
    Guzelkucuk, Umut
    Yasar, Evren
    Balaban, Birol
    TURKISH JOURNAL OF PHYSICAL MEDICINE AND REHABILITATION, 2017, 63 (02): : 143 - 148
  • [2] The effect of anterior ankle-foot orthosis and posterior ankle-foot orthosis on functional ambulation in stroke patients
    Zarezadeh, Reihaneh
    Arazpour, Mokhtar
    Aminian, Gholamreza
    JOURNAL OF REHABILITATION AND ASSISTIVE TECHNOLOGIES ENGINEERING, 2022, 9
  • [3] The effect of anterior ankle-foot orthosis and posterior ankle-foot orthosis on functional ambulation in stroke patients
    Zarezadeh, Reihaneh
    Arazpour, Mokhtar
    Aminian, Gholamreza
    Journal of Rehabilitation and Assistive Technologies Engineering, 2022, 9
  • [4] THE EFFECT OF KNEE-ANKLE-FOOT ORTHOSIS ON AMBULATION OUTCOME AFTER STROKE
    BELLANTONI, L
    HEFFERNAN, C
    OYEDIJO, O
    REDING, M
    CLINICAL RESEARCH, 1992, 40 (01): : A119 - A119
  • [5] Weight transfer analysis in adults with hemiplegia using ankle foot orthosis
    Nolan, Karen J.
    Yarossi, Mathew
    PROSTHETICS AND ORTHOTICS INTERNATIONAL, 2011, 35 (01) : 45 - 53
  • [6] Method for Ankle Foot Orthotics' Mechanical Assessment: A Pilot Study
    Krukonis, K.
    Daunoraviciene, K.
    Griskevicius, J.
    Kilikevicius, A.
    MECHANIKA, 2017, 23 (05): : 723 - 727
  • [7] Functional Electrical Stimulation to Ankle Dorsiflexor and Plantarflexor Using Single Foot Switch in Patients With Hemiplegia From Hemorrhagic Stroke
    Lee, Young-Hee
    Yong, Sang Yeol
    Kim, Sung Hoon
    Kim, Ji Hyun
    Shinn, Jong Mock
    Kim, Youngho
    Kim, Seunghyeon
    Hwang, Seonhong
    ANNALS OF REHABILITATION MEDICINE-ARM, 2014, 38 (03): : 310 - 316
  • [8] Peroneal nerve stimulation versus an ankle foot orthosis for correction of footdrop in stroke: Impact on functional ambulation
    Sheffler, Lynne R.
    Hennessey, Maureen T.
    Naples, Gregory G.
    Chae, John
    NEUROREHABILITATION AND NEURAL REPAIR, 2006, 20 (03) : 355 - 360
  • [9] Effects of ankle foot orthosis in stiff knee gait in adults with hemiplegia
    Andres Gatti, Marcelo
    Freixes, Orestes
    Anibal Fernandez, Sergio
    Elisa Rivas, Maria
    Crespo, Marcos
    Waldman, Silvina V.
    Emilio Olmos, Lisandro
    JOURNAL OF BIOMECHANICS, 2012, 45 (15) : 2658 - 2661
  • [10] Mediolateral foot placement ability during ambulation in individuals with chronic post-stroke hemiplegia
    Zissimopoulos, Angelika
    Stine, Rebecca
    Fatone, Stefania
    Gard, Steven
    GAIT & POSTURE, 2014, 39 (04) : 1097 - 1102