Measurements with magnetic field in the National Spherical Torus Experiment using the motional Stark effect with laser induced fluorescence diagnostic

被引:3
|
作者
Foley, E. L. [1 ]
Levinton, F. M. [1 ]
机构
[1] Nova Photon Inc, Princeton, NJ 08540 USA
来源
REVIEW OF SCIENTIFIC INSTRUMENTS | 2013年 / 84卷 / 04期
关键词
HYDROGEN;
D O I
10.1063/1.4802691
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The motional Stark effect with laser-induced fluorescence diagnostic (MSE-LIF) has been installed and tested on the National Spherical Torus Experiment (NSTX) at the Princeton Plasma Physics Lab. The MSE-LIF diagnostic will be capable of measuring radially resolved profiles of magnetic field magnitude or pitch angle in NSTX plasmas. The system includes a diagnostic neutral hydrogen beam and a laser which excites the n = 2 to n = 3 transition. A viewing system has been implemented which will support up to 38 channels from the plasma edge to past the magnetic axis. First measurements of MSE-LIF signals in the presence of small applied magnetic fields in neutral gas are reported. (C) 2013 AIP Publishing LLC. [http://dx.doi.org/10.1063/1.4802691]
引用
收藏
页数:5
相关论文
共 46 条
  • [1] The Motional Stark Effect with Laser-Induced Fluorescence Diagnostic
    Foley, E. L.
    Levinton, F. M.
    14TH INTERNATIONAL SYMPOSIUM ON LASER-AIDED PLASMA DIAGNOSTICS (LAPD14), 2010, 227
  • [2] Development of the motional Stark effect with laser-induced fluorescence diagnostic
    Foley, EL
    Levinton, FM
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2004, 75 (10): : 3462 - 3464
  • [3] Progress on the motional Stark effect with laser-induced fluorescence diagnostic
    Foley, E. L.
    Levinton, F. M.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2006, 77 (10):
  • [4] Pedestal magnetic field measurements using a motional Stark effect polarimeter
    Lanctot, M. J.
    Holcomb, C. T.
    Allen, S. L.
    Fenstermacher, M. E.
    Luce, T. C.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2012, 83 (10):
  • [5] Measurements of the internal magnetic field using the B-Stark motional Stark effect diagnostic on DIII-D (inivited)
    Pablant, N. A.
    Burrell, K. H.
    Groebner, R. J.
    Holcomb, C. T.
    Kaplan, D. H.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2010, 81 (10):
  • [6] Measurements of the radial profile of magnetic field in the Gas-Dynamic Trap using a motional Stark effect diagnostic
    Bagryansky, PA
    Deichuli, PP
    Ivanov, AA
    Korepanov, SA
    Lizunov, AA
    Murakhtin, SV
    Savkin, VY
    Den Hartog, DJ
    Fiksel, G
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2003, 74 (03): : 1592 - 1595
  • [7] MAGNETIC-FIELD PITCH ANGLE DIAGNOSTIC USING THE MOTIONAL STARK-EFFECT
    LEVINTON, FM
    GAMMEL, GM
    KAITA, R
    KUGEL, HW
    ROBERTS, DW
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1990, 61 (10): : 2914 - 2919
  • [8] A Stark-tuned laser application for interferometry and polarimetry on the National Spherical Torus Experiment
    Lee, KC
    Domier, CW
    Deng, BH
    Johnson, M
    Nathan, BR
    Luhmann, NC
    Park, H
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2003, 74 (03): : 1621 - 1624
  • [9] Infrared camera diagnostic for heat flux measurements on the National Spherical Torus Experiment
    Mastrovito, D
    Maingi, R
    Kugel, HW
    Roquemore, AL
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2003, 74 (12): : 5090 - 5092
  • [10] MAGNETIC-FIELD MEASUREMENTS WITH A LITHIUM-BEAM USING ZEEMAN-STARK-EFFECT OR MOTIONAL-STARK-EFFECT
    DULLNI, E
    LEISMANN, P
    MAURMANN, S
    VONREVENTLOW, C
    KUNZE, HJ
    PHYSICA SCRIPTA, 1986, 34 (05): : 405 - 407