Proof of feasibility of the Vacuum Silicon PhotoMultiplier Tube (VSiPMT)

被引:9
|
作者
Barbarino, G. [1 ,2 ]
Campajola, L. [1 ]
de Asmundis, R. [2 ]
De Rosa, G. [1 ,2 ]
Fiorillo, G. [1 ,2 ]
Migliozzi, P. [2 ]
Barbato, F. C. T. [1 ,2 ]
Mollo, C. M. [2 ]
Russo, A. [1 ,2 ]
Vivolo, D. [1 ,2 ]
机构
[1] Univ Naples Federico II, Dipartimento Fis, I-80126 Naples, Italy
[2] Ist Nazl Fis Nucl, Sez Napoli, I-80126 Naples, Italy
来源
关键词
Hybrid detectors; Photon detectors for UV; visible and IR photons (vacuum) (photomultipliers; HPDs; others); Solid state detectors; Vacuum-based detectors; GEIGER-MODE;
D O I
10.1088/1748-0221/8/04/P04021
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The Vacuum Silicon PhotoMultiplier Tube (VSiPMT) is an innovative design we propose for a modern hybrid photodetector based on the combination of a Silicon PhotoMultiplier (SiPM) with a hemispherical vacuum glass PMT standard envelope. The basic idea is to replace the classical dynode chain of a PMT with a SiPM, which acts as an electron multiplying detector. Such a solution will match the goal of a large photocathode sensitive area with the performances of a SiPM. This will lead to many advantages such as lower power consumption, mild sensitivity to magnetic fields and high quantum efficiency. The feasibility of this idea has been throughly studied both from a theoretical and experimental point of view. As a first step we performed the full characterization of a special non-windowed Hamamatsu MPPC with a laser source. The response of the SiPM to an electron beam was studied as a function of the energy and of the incident angle by means of a Geant4-based simulation. In this paper we present the preliminary results of the characterization of the SiPM with an electron source and we discuss how the development of next generation SiPMs will overcome the main weaknesses of VSiPMT, such as relatively low PDE and high photocathode voltage.
引用
收藏
页数:13
相关论文
共 50 条
  • [1] The Vacuum Silicon Photomultiplier Tube (VSiPMT): A new version of a hybrid photon detector
    Russo, Stefano
    Barbarino, Giancarlo
    de Asmundis, Riccardo
    De Rosa, Gianfranca
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2010, 623 (01): : 291 - 293
  • [2] Vacuum Silicon PhotoMultiplier Tube (VSiPMT): towards a new generation of photon detectors
    Barbarino, G.
    Barbato, F. C. T.
    De Rosa, G.
    Fiorillo, G.
    Vivolo, D.
    de Asmundis, R.
    Migliozzi, P.
    Mollo, C. M.
    Rossi, B.
    2014 FOTONICA AEIT ITALIAN CONFERENCE ON PHOTONICS TECHNOLOGIES, 2014,
  • [3] The Vacuum Silicon Photomultiplier Tube (VSiPMT): a New Concept of Photon Detector. First Feasibility Results.
    Russo, Stefano
    Barbarino, Giancarlo
    de Asmundis, Riccardo
    De Rosa, Gianfranca
    2009 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2009, : 1966 - +
  • [4] The Silicon Photomultiplier as a modern solid-state replacement of the vacuum photomultiplier tube
    Ponento, A.
    Martoff, C. J.
    Jones, D.
    Kaczanowicz, E.
    JOURNAL OF INSTRUMENTATION, 2019, 14 (08):
  • [5] First results of performance tests of the newly designed Vacuum Silicon Photo Multiplier Tube (VSiPMT).
    de Asmundis, R.
    Barbarino, G.
    Barbato, F. C. T.
    Campajola, L.
    De Rosa, G.
    Fiorillo, G.
    Migliozzi, P.
    Mollo, C. M.
    Rossi, B.
    Vivolo, D.
    JOURNAL OF INSTRUMENTATION, 2014, 9
  • [6] Comparison of a silicon photomultiplier to a traditional vacuum photomultiplier
    Kovaltchouk, VD
    Lolos, GJ
    Papandreou, Z
    Wolbaum, K
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2005, 538 (1-3): : 408 - 415
  • [7] Comparison of NaI coupled to photomultiplier tube and silicon photomultiplier
    Liang, Felix
    Hoy, Les
    2018 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE PROCEEDINGS (NSS/MIC), 2018,
  • [8] REVERSE EPITAXIAL SILICON DIODE FOR HYBRID PHOTOMULTIPLIER TUBE
    FERTIN, J
    LACH, B
    MEULEMAN, J
    DUPUIS, J
    LHERMITE
    PETIT, R
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1968, NS15 (03) : 179 - +
  • [9] Comparative studies of silicon photomultipliers and traditional vacuum photomultiplier tubes
    石峰
    吕军光
    卢红
    王焕玉
    马宇蒨
    胡涛
    周莉
    蔡啸
    孙丽君
    俞伯祥
    方建
    谢宇广
    安正华
    王志刚
    高旻
    李新乔
    徐岩冰
    王平
    孙希磊
    章爱武
    薛镇
    刘宏邦
    王晓东
    赵小芸
    郑阳恒
    孟祥承
    王辉
    中国物理C, 2011, (01) : 50 - 55
  • [10] Comparative studies of silicon photomultipliers and traditional vacuum photomultiplier tubes
    Shi Feng
    Lue Jun-Guang
    Lu Hong
    Wang Huan-Yu
    Ma Yu-Qian
    Hu Tao
    Zhou Li
    Cai Xiao
    Sun Li-Jun
    Yu Bo-Xiang
    Fang Jian
    Xie Yu-Guang
    An Zheng-Hua
    Wang Zhi-Gang
    Gao Min
    Li Xu-Qiao
    Xu Yan-Bing
    Wang Ping
    Sun Xi-Lei
    Zhang Ai-Wu
    Xue Zhen
    Liu Hong-Bang
    Wang Xiao-Dong
    Zhao Xiao-Yun
    Zheng Yang-Heng
    Meng Xiang-Cheng
    Wang Hui
    CHINESE PHYSICS C, 2011, 35 (01) : 50 - 55