Technique of Subnormothermic Ex Vivo Liver Perfusion for the Storage, Assessment, and Repair of Marginal Liver Grafts

被引:13
|
作者
Knaak, Jan M. [1 ,2 ]
Spetzler, Vinzent N. [1 ,2 ]
Goldaracena, Nicolas [1 ,2 ]
Louis, Kristine S. [1 ,2 ]
Selzner, Nazia [1 ,3 ]
Selzner, Markus [1 ,2 ]
机构
[1] Toronto Gen Hosp, Multi Organ Transplant Program, Toronto, ON, Canada
[2] Toronto Gen Hosp, Dept Surg, Toronto, ON, Canada
[3] Toronto Gen Hosp, Dept Med, Toronto, ON, Canada
来源
关键词
Medicine; Issue; 90; ex vivo liver perfusion; marginal grafts; DCD;
D O I
10.3791/51419
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
The success of liver transplantation has resulted in a dramatic organ shortage. In most transplant regions 20-30% of patients on the waiting list for liver transplantation die without receiving an organ transplant or are delisted for disease progression. One strategy to increase the donor pool is the utilization of marginal grafts, such as fatty livers, grafts from older donors, or donation after cardiac death (DCD). The current preservation technique of cold static storage is only poorly tolerated by marginal livers resulting in significant organ damage. In addition, cold static organ storage does not allow graft assessment or repair prior to transplantation. These shortcomings of cold static preservation have triggered an interest in warm perfused organ preservation to reduce cold ischemic injury, assess liver grafts during preservation, and explore the opportunity to repair marginal livers prior to transplantation. The optimal pressure and flow conditions, perfusion temperature, composition of the perfusion solution and the need for an oxygen carrier has been controversial in the past. In spite of promising results in several animal studies, the complexity and the costs have prevented a broader clinical application so far. Recently, with enhanced technology and a better understanding of liver physiology during ex vivo perfusion the outcome of warm liver perfusion has improved and consistently good results can be achieved. This paper will provide information about liver retrieval, storage techniques, and isolated liver perfusion in pigs. We will illustrate a) the requirements to ensure sufficient oxygen supply to the organ, b) technical considerations about the perfusion machine and the perfusion solution, and c) biochemical aspects of isolated organs.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] Normothermic Acellular Ex Vivo Liver Perfusion (NEVLP): Development of a New Method for the Storage, Assessment, and Repair of Marginal Liver Grafts
    Boehnert, M. U.
    Knaak, M.
    Keshavjee, S.
    Levy, G. A.
    Grant, D. R.
    Selzner, M.
    TRANSPLANTATION, 2012, 94 (10) : 174 - 174
  • [2] Normothermic Acellular Ex Vivo Liver Perfusion (NEVLP): Development of a New Method for the Storage, Assessment, and Repair of Marginal Liver Grafts
    Boehnert, M.
    Knaak, J.
    Adeyi, O.
    Yip, P.
    Selzner, N.
    Levy, G.
    Keshavjee, S.
    Grant, D.
    Selzner, M.
    AMERICAN JOURNAL OF TRANSPLANTATION, 2013, 13 : 519 - 519
  • [3] SUBNORMOTHERMIC EX VIVO LIVER PERFUSION IS A SAFE ALTERNATIVE TO COLD STORAGE FOR STANDARD QUALITY GRAFTS AND ALLOWS GRAFT ASSESSMENT DURING LIVER PRESERVATION
    Spetzler, V.
    Goldaracena, N.
    Knaak, M.
    Louis, K.
    Grant, D.
    Selzner, N.
    Bechstein, W.
    Selzner, M.
    TRANSPLANT INTERNATIONAL, 2014, 27 : 42 - 42
  • [4] Towards the repair of marginal liver grafts: Ex vivo Mesenchymal stromal cell perfusion
    Bartczak, Agata
    Ma, Xue-Zhong
    Manuel, Justin
    Zhang, Xing-Hua
    Cifuentes, Juan Andres Echeverri
    Linares, Ivan
    Selzner, Markus
    Keating, Armand
    McGilvray, Ian
    JOURNAL OF IMMUNOLOGY, 2016, 196
  • [5] Subnormothermic Ex Vivo Liver Perfusion Is a Safe Alternative to Cold Static Storage for Preserving Standard Criteria Grafts
    Spetzler, Vinzent N.
    Goldaracena, Nicolas
    Echiverri, Juan
    Kaths, J. Moritz
    Louis, Kristine S.
    Adeyi, Oyedele A.
    Yip, Paul M.
    Grant, David R.
    Selzner, Nazia
    Selzner, Markus
    LIVER TRANSPLANTATION, 2016, 22 (01) : 111 - 119
  • [6] Normothermic and subnormothermic ex-vivo liver perfusion in liver transplantation
    Goldaracena, Nicolas
    Barbas, Andrew S.
    Selzner, Markus
    CURRENT OPINION IN ORGAN TRANSPLANTATION, 2016, 21 (03) : 315 - 321
  • [7] Acellular Normothermic Ex Vivo Liver Perfusion: A Novel Technique of Graft Storage, Assessment, and Repair
    Yeung, Jonathan C.
    Bazerbachi, Fateh
    Koike, Terumoto
    Selzner, Nazia
    Keshavjee, Shaf
    Levy, Gary A.
    Grant, David R.
    Selzner, Markus
    LIVER TRANSPLANTATION, 2010, 16 (06) : S223 - S224
  • [8] Subnormothermic Machine Perfusion for Ex Vivo Preservation and Recovery of the Human Liver for Transplantation
    Bruinsma, B. G.
    Yeh, H.
    Oezer, S.
    Martins, P. N.
    Farmer, A.
    Wu, W.
    Saeidi, N.
    Op den Dries, S.
    Berendsen, T. A.
    Smith, R. N.
    Markmann, J. F.
    Porte, R. J.
    Yarmush, M. L.
    Uygun, K.
    Izamis, M. -L.
    AMERICAN JOURNAL OF TRANSPLANTATION, 2014, 14 (06) : 1400 - 1409
  • [9] Rescue of Discarded Grafts for Liver Transplantation by Ex Vivo Subnormothermic and Normothermic Oxygenated Machine Perfusion: First Experience in Spain
    Ciria, R.
    Ayllon-Teran, M. D.
    Gonzalez-Rubio, S.
    Gomez-Luque, I.
    Ferrin, G.
    Moreno, A.
    Sanchez-Frias, M.
    Alconchel, F.
    Herrera, C.
    Martin, V.
    Sanchez-Hidalgo, J. M.
    Arjona-Sanchez, A.
    Okuda, Y. a
    Cabrera, I.
    Benavente, B.
    Rodriguez, M. J.
    Jurado-Martinez, I.
    Duenas-Jurado, J. M.
    Robles-Arista, J. C.
    Rodriguez-Peralvarez, M.
    De la Mata Garcia, M.
    Lopez-Cillero, P.
    Briceno, J.
    TRANSPLANTATION PROCEEDINGS, 2019, 51 (01) : 20 - 24
  • [10] Ex vivo liver perfusion:: A successful technique of liver support
    Filipponi, F
    Boggi, U
    Meacci, L
    Burchielli, S
    Barbieri, U
    Bellentani, S
    Fassati, LR
    Tiribelli, C
    Costa, G
    GASTROENTEROLOGY, 1998, 114 (04) : A1240 - A1240