共 50 条
Total wrist arthroplasty: a systematic review of the evidence from the last 5 years
被引:58
|作者:
Yeoh, D.
[1
]
Tourret, L.
[1
]
机构:
[1] Brighton & Sussex Univ Hosp, Brighton BN2 5BE, E Sussex, England
关键词:
Systematic review;
total wrist arthroplasty;
total wrist replacement;
OUTCOMES;
ARTHRODESIS;
D O I:
10.1177/1753193414539796
中图分类号:
R826.8 [整形外科学];
R782.2 [口腔颌面部整形外科学];
R726.2 [小儿整形外科学];
R62 [整形外科学(修复外科学)];
学科分类号:
摘要:
We reviewed evidence on total wrist replacement from the last 5 years. Eight articles met a minimum set standard. The results of 405 prostheses were available, including seven different manufacturers. The mean follow up was 2.3-7.3 years with an average age of 52-63. Rheumatoid arthritis was the indication in 42% of patients. Motec demonstrated the best post-operative DASH scores. Only Maestro achieved a defined functional range of motion post-operatively. Universal 2 displayed the highest survival rates (100% at 3-5 years), while Elos had the lowest (57% at 5 years). Biaxial had the highest complication rates (68.7%), while Remotion had the lowest (11%). Wrist arthroplasty preserves some range of motion. Functional scores improved and were maintained over the mid- to long-term. Complication rates were higher than wrist fusion, with reports of radiological loosening and osteolysis. The evidence does not support the widespread use of arthroplasty over arthrodesis, and careful patient selection is essential. Level of Evidence: III
引用
收藏
页码:458 / 468
页数:11
相关论文