Numerical simulation of radiant syngas cooler with different connection to entrained-flow gasifier

被引:6
|
作者
Wang, Lei [1 ]
Xu, Jianliang [1 ]
Wei, Juntao [2 ]
Guo, Qinghua [1 ]
Gong, Yan [1 ]
Yu, Guangsuo [1 ,3 ]
机构
[1] East China Univ Sci & Technol, Inst Clean Coal Technol, Shanghai 200237, Peoples R China
[2] Nanjing Forestry Univ, Coll Mat Sci & Engn, Coinnovat Ctr Efficient Proc & Utilizat Forest Re, Joint Int Res Lab Biomass Energy & Mat, Nanjing 210037, Peoples R China
[3] Ningxia Univ, Coll Chem Engn, State Key Lab High Efficiency Utilizat Coal & Gre, Yinchuan 750021, Peoples R China
基金
中国国家自然科学基金;
关键词
Numerical simulation; Radiant syngas cooler; Multiphase flow; Structure optimization; COAL-GASIFICATION; SLAG DEPOSITION; MODEL; CAPTURE; GAS;
D O I
10.1016/j.applthermaleng.2021.117804
中图分类号
O414.1 [热力学];
学科分类号
摘要
The throat region of radiant syngas cooler (RSC) is a key part for connecting the entrained-flow gasifier with RSC, and an annular step is employed in the throat region of the connection to separate the molten slag from the hightemperature gasification products discharged from the gasifier. Multiphase flow and heat transfer in four types of connection designs (i.e., straight cylindrical connection (SCC), straight cylindrical connection with annular-step (SCCA), tapered connection with annular-step (TCA), and divergent connection with annular-step (DCA)) have been studied in this work. The radiation heat transfer is simulated by the discrete ordinates model (DOM). Comparing simulated values with industrial measured values, the reliability and accuracy of the mathematic models are validated with the maximum relative error of 3.7%. Simulation results show that a torch shape inject flow is formed at the top of the RSC, and the temperature of inject region is higher than that of nearby zone. Flow field distribution is changed by the annular step and tapered region, and thus results in twice dissipation of the central jet flow. The annular step can accelerate the dissipation of the turbulent flow, and the geometry of the throat region has a great influence on the size and intensity of the recirculation bubble. The tapered region of TCA makes the first recirculation more obvious than that of the DCA and SCCA, which causes that the recirculation regions have a tendency to coalescence. The jet dissipation position moves upwards due to the changes of connection structure, which is beneficial to enhance the heat exchange performance between the syngas and membrane wall. The changes of connection structure make the particle dispersion position move upward, but can alleviate the particle dispersion.
引用
收藏
页数:11
相关论文
共 50 条
  • [1] Numerical Simulation of the Integral Thermal Deformation Behavior of a Radiant Syngas Cooler for an Entrained-Flow Gasifier
    Zhang, Guoyu
    Xu, Jianliang
    Gong, Yan
    Guo, Qinghua
    Yu, Guangsuo
    INDUSTRIAL & ENGINEERING CHEMISTRY RESEARCH, 2023, 62 (50) : 21852 - 21861
  • [2] Numerical study on the performance of an adapted radiant syngas cooler with water spray for entrained-flow gasifier
    Li, Xianbin
    Guo, Qinghua
    Qiu, Shouxian
    Yu, Guangsuo
    ASIA-PACIFIC JOURNAL OF CHEMICAL ENGINEERING, 2016, 11 (02) : 246 - 257
  • [3] Numerical simulation of flow and heat transfer in connection of gasifier to the radiant syngas cooler
    Ni, Jianjun
    Liang, Qinfeng
    Yan, Zhuoyong
    Yu, Zunhong
    Yu, Guangsuo
    ASIA-PACIFIC JOURNAL OF CHEMICAL ENGINEERING, 2009, 4 (05) : 683 - 690
  • [4] Simulation of Radiant Syngas Coolers and Comparison with Various Arrangements of the Entrained-Flow Gasifier
    Li, Xianbin
    Gong, Yan
    Zhou, Zhijie
    Dai, Zhenghua
    Yu, Guangsuo
    CHEMICAL ENGINEERING & TECHNOLOGY, 2016, 39 (08) : 1457 - 1467
  • [5] Mechanical properties of slag in a radiant syngas cooler of entrained flow gasifier
    Shao, Lintao
    Liu, Chongguo
    Jiang, Cancheng
    Xia, Zhiwen
    Zhou, Zhijun
    Kuang, Jianping
    Yang, Weijuan
    Meitan Xuebao/Journal of the China Coal Society, 2021, 46 (03): : 1039 - 1045
  • [6] Chemistry variation of slag and the layered characteristics of deposits in an industrialized entrained-flow gasifier system with radiant syngas cooler
    Xuan, Weiwei
    Zhang, Yongquan
    Zhang, Jiansheng
    ENERGY, 2022, 260
  • [7] Multiphase flow and heat transfer in entrained-flow coal gasification radiant syngas cooler
    Key Laboratory of Coal Gasification, Ministry of Education, East China University of Science and Technology, Shanghai 200237, China
    不详
    Huagong Xuebao, 2009, 12 (2997-3005):
  • [8] Numerical Simulation of Ash Deposition in Entrained-flow Gasifier
    Du, Min
    Hao, Yingli
    2009 ASIA-PACIFIC POWER AND ENERGY ENGINEERING CONFERENCE (APPEEC), VOLS 1-7, 2009, : 294 - 297
  • [9] Modeling of Multiphase Flow and Heat Transfer in Radiant Syngas Cooler of an Entrained-Flow Coal Gasification
    Yu, Guangsuo
    Ni, Jianjun
    Liang, Qinfeng
    Guo, Qinghua
    Zhou, Zhijie
    INDUSTRIAL & ENGINEERING CHEMISTRY RESEARCH, 2009, 48 (22) : 10094 - 10103
  • [10] Modeling and comparison of different syngas cooling types for entrained-flow gasifier
    Ni, Jianjun
    Yu, Guangsuo
    Guo, Qinghua
    Dai, Zhenghua
    Wang, Fuchen
    CHEMICAL ENGINEERING SCIENCE, 2011, 66 (03) : 448 - 459