GenoMass software: a tool based on electrospray ionization tandem mass spectrometry for characterization and sequencing of oligonucleotide adduct

被引:2
|
作者
Sharma, Vaneet K. [1 ,2 ]
Glick, James [2 ]
Liao, Qing [5 ]
Shen, Chang [6 ]
Vouros, Paul [3 ,4 ]
机构
[1] Northeastern Univ, Dept Chem & Chem Biol, Boston, MA 02115 USA
[2] Northeastern Univ, Barnett Inst Chem & Biol Anal, Boston, MA 02115 USA
[3] Baylor Coll Med, Inst Lipid Res, Houston, TX 77030 USA
[4] Northeastern Univ, Barnett Inst, Boston, MA 02115 USA
[5] Harvard Univ, Mass Spectrometry Facil, Cambridge, MA 02138 USA
[6] Shenitech LLC, Acton, MA USA
来源
JOURNAL OF MASS SPECTROMETRY | 2012年 / 47卷 / 04期
基金
美国国家卫生研究院;
关键词
D O I
10.1002/jms.3002
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The analysis of DNA adducts is of importance in understanding DNA damage, and in the last few years mass spectrometry (MS) has emerged as the most comprehensive and versatile tool for routine characterization of modified oligonucleotides. The structural analysis of modified oligonucleotides, although routinely analyzed using mass spectrometry, is followed by a large amount of data, and a significant challenge is to locate the exact position of the adduct by computational spectral interpretation, which still is a bottleneck. In this report, we present an additional feature of the in-house developed GenoMass software, which determines the exact location of an adduct in modified oligonucleotides by connecting tandem mass spectrometry (MS/MS) to a combinatorial isomer library generated in silico for nucleic acids. The performance of this MS/MS approach using GenoMass software was evaluated by MS/MS data interpretation for an unadducted and its corresponding N-acetylaminofluorene (AAF) adducted 17-mer (5'OH-CCT ACC CCT TCC TTG TA-3'OH) oligonucleotide. Further computational screening of this AAF adducted 17-mer oligonucleotide (5'OH-CCT ACC CCT TCC TTG TA-3'OH) from a complex oligonucleotide mixture was performed using GenoMass. Finally, GenoMass was also used to identify the positional isomers of the AAF adducted 15-mer oligonucleotide (5'OH-ATGAACCGGAGGCCC-3'OH). GenoMass is a simple, fast, data interpretation software that uses an in silico constructed library to relate the MS/MS sequencing approach to identify the exact location of adduct on oligonucleotides. Copyright (c) 2012 John Wiley & Sons, Ltd.
引用
收藏
页码:490 / 501
页数:1
相关论文
共 50 条
  • [1] Characterization of phosphatidylethanolamine as a lithiated adduct by triple quadrupole tandem mass spectrometry with electrospray ionization
    Hsu, FF
    Turk, J
    JOURNAL OF MASS SPECTROMETRY, 2000, 35 (05): : 596 - 606
  • [2] Deconvolution of combinatorial oligonucleotide libraries by electrospray ionization tandem mass spectrometry
    Pomerantz, SC
    McCloskey, JA
    Tarasow, TM
    Eaton, BE
    JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1997, 119 (17) : 3861 - 3867
  • [3] Tandem mass spectrometry with electrospray ionization - New tool for speciation
    Chassaigne, H
    Lobinski, R
    ANALUSIS, 1997, 25 (02) : M37 - M40
  • [4] Characterization of ammonium nitrate by electrospray ionization tandem mass spectrometry
    Zhao, XM
    Yinon, J
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2001, 15 (17) : 1514 - 1519
  • [5] Characterization of stereoisomeric alkaloids by electrospray ionization tandem mass spectrometry
    Munari, I
    Traldi, P
    Biala, J
    Czarnocki, Z
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2001, 15 (11) : 889 - 892
  • [6] Coceth sulfate characterization by electrospray ionization tandem mass spectrometry
    Onzo, Alberto
    Acquavia, Maria A.
    Cataldi, Tommaso R. I.
    Ligonzo, Mattia
    Coviello, Donatella
    Pascale, Raffaella
    Martelli, Giuseppe
    Bondoni, Marcella
    Scrano, Laura
    Bianco, Giuliana
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2020, 34 (20)
  • [7] Structural characterization of polymethoxymethylsiloxanes by electrospray ionization tandem mass spectrometry
    Fouquet, Thierry
    Ziarelli, Fabio
    Sato, Hiroaki
    Charles, Laurence
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2016, 402 : 42 - 48
  • [8] Interpretation of oligonucleotide mass spectra for determination of sequence using electrospray ionization and tandem mass spectrometry
    Ni, JS
    Pomerantz, SC
    Rozenski, J
    Zhang, YH
    McCloskey, JA
    ANALYTICAL CHEMISTRY, 1996, 68 (13) : 1989 - 1999
  • [9] Interpretation of oligonucleotide mass spectra for determination of sequence using electrospray ionization and tandem mass spectrometry
    Depts. of Med. Chem. and Biochem., University of Utah, Salt Lake City, UT 84112, United States
    不详
    ANAL. CHEM., 13 (1989-1999):
  • [10] Characterization of ageing products of ester-based synthetic lubricants by liquid chromatography with electrospray ionization mass spectrometry and by electrospray ionization (tandem) mass spectrometry
    Kohler, M
    Heeb, NV
    JOURNAL OF CHROMATOGRAPHY A, 2001, 926 (01) : 161 - 165