Comparison of the Barrett toric calculator using measured and predicted posterior corneal astigmatism and the Kane and Abulafia-Koch calculators

被引:11
|
作者
Reitblat, Olga [1 ,2 ,3 ]
Barnir, Megiddo [3 ,4 ,6 ]
Qassoom, Ayat [3 ,4 ]
Levy, Adi [1 ]
Assia, Ehud I. [1 ,3 ,5 ]
Kleinmann, Guy [1 ,3 ,4 ]
机构
[1] Ein Tal Eye Ctr, Tel Aviv, Israel
[2] Rabin Med Ctr, Dept Ophthalmol, Petah Tiqwa, Israel
[3] Tel Aviv Univ, Ramat Aviv, Israel
[4] Edith Wolfson Med Ctr, Dept Ophthalmol, Holon, Israel
[5] Meir Med Ctr, Dept Ophthalmol, Kefar Sava, Israel
[6] Vissum Miranza Grp, Cornea Cataract & Refract Surg Unit, Alicante, Spain
来源
JOURNAL OF CATARACT AND REFRACTIVE SURGERY | 2023年 / 49卷 / 07期
关键词
REFRACTIVE OUTCOMES; ACCURACY; SURGERY; FORMULA; EYES;
D O I
10.1097/j.jcrs.0000000000001178
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To compare the accuracy of the Barrett toric calculator with measured and predicted posterior corneal astigmatism (MPCA and PPCA, respectively), the Abulafia-Koch (AK) formula, and the toric Kane formula. Setting: Ein-Tal Eye Center, Tel-Aviv, Israel. Design: Retrospective cohort. Methods: Consecutive cases of patients who underwent uneventful cataract extraction surgery with implantation of a toric intraocular lens between March 2015 and July 2019 were retrospectively reviewed. 1 eligible eye from each patient was included. The predicted postoperative refractive astigmatism was calculated using each method and compared with the postoperative refractive astigmatism to give the prediction error. Results: 80 eyes of 80 patients were included in this study. Themean centroid and the mean and median absolute prediction errors using Kane (0.25 diopters [D] +/- 0.54@ 6 degrees, 0.50 D +/- 0.31 and 0.45 D, respectively) were significantly different compared withMPCA(0.12D +/- 0.52 @ 16 degrees, P <.001,.44 D +/- 0.28 and 0.36 D, P =.027, respectively), PPCA (0.09 D +/- 0.49 @ 12 degrees, P <.001,.41 D +/- 0.27 and 0.35 D, P <.001, respectively), and AK (0.11 D +/- 0.49 @ 11 degrees, P <.001,.42 D +/- 0.27 and 0.35 D, P =.004, respectively). No significant differences were found between the calculators in the predictability rates within +/- 0.25 D, +/- 0.50 D, +/- 0.75 D, and +/- 1.00 D. Conclusions: The measured posterior corneal curvature in the Barrett calculator yielded comparable outcomes to its prediction by the Barrett and AK formulas. The Kane calculator showed a slight against-the-rule prediction error compared with the other methods, resulting in a small higher median absolute error with marginal clinical importance.
引用
收藏
页码:704 / 710
页数:7
相关论文
共 17 条
  • [1] Comparison of accuracy of a toric calculator with predicted vs measured posterior corneal astigmatism
    Wang, Li
    Koch, Douglas D.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2023, 49 (01): : 29 - 33
  • [2] Comparative Accuracy of Barrett Integrated Keratometry Toric Calculator With Predicted Versus Measured Posterior Corneal Astigmatism
    Yang, Xiaotong
    Yin, Yufan
    Wang, Shuyang
    Bai, Xiaomei
    Jiang, Yuanfeng
    Bu, Shaochong
    JOURNAL OF REFRACTIVE SURGERY, 2024, 40 (07) : E453 - +
  • [3] Comparative Accuracy of Barrett Toric Calculator With and Without Posterior Corneal Astigmatism Measurements and the Kane Toric Formula
    Yang, Soonwon
    Byun, Yong-soo
    Kim, Hyun Seung
    Chung, So-hyang
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2021, 231 : 48 - 57
  • [4] Comparative accuracy of Barrett toric calculator with and without posterior corneal astigmatism measurements and the Kane toric formula
    Yang, Soowon
    Byun, Yong-Soo
    Kim, Hyun Seung
    Chung, So-Hyang
    CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2022, 49 (08): : 879 - 879
  • [5] Comparison of Barrett Toric Calculations Using Measured and Predicted Posterior Corneal Astigmatism in Cataract Surgery Patients
    Lukewich, Mark K.
    Murtaza, Fahmeeda
    Somani, Sohel
    Tam, Eric S.
    Chiu, Hannah H.
    CLINICAL OPHTHALMOLOGY, 2022, 16 : 1739 - 1751
  • [6] Posterior Corneal Astigmatism for Toric IOL Calculations: A Comparison Between the Barrett Toric Calculator Predicted Astigmatism Versus Direct Posterior Corneal Measurement with a Scheimpflug Camera
    Kingrey, Brandon S.
    Kingrey, David
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2020, 61 (07)
  • [7] Predictive accuracy of Barrett TK toric calculator compared to measured posterior corneal astigmatism using Pentacam in toric IOL power calculation
    Tamilarasi, S.
    Joseph, Ashalyne James
    Dandapani, Ramamurthy
    INDIAN JOURNAL OF OPHTHALMOLOGY, 2024, 72 (04) : 582 - 586
  • [8] Predicted vs measured posterior corneal astigmatism for toric intraocular lens calculations
    Shammas, H. John
    Yu, Fei
    Shammas, Maya C.
    Jivrajka, Renu
    Hakimeh, Christine
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2022, 48 (06): : 690 - 696
  • [9] Impact of Total Corneal Astigmatism Estimated With the Abulafia-Koch Formula Versus Measured With a SS-OCT Biometer on the Refractive Outcomes of a Toric Intraocular Lens in Cataract Surgery
    Remignon, Charles-Henry
    Levron, Antoine
    Agard, Emilie
    Douma, Ikrame
    El-Chehab, Hussam
    Brunet, Olivier
    Sejournet, Lucas
    Billant, Jeremy
    Dot, Corinne
    JOURNAL OF REFRACTIVE SURGERY, 2023, 39 (03) : 171 - 179
  • [10] The predictive accuracy of Barrett toric calculator using measured posterior corneal astigmatism derived from swept source-OCT and Scheimpflug camera
    Xiaotong Yang
    Yuanfeng Jiang
    Song Lin
    Xiaomei Bai
    Yufan Yin
    FangYu Zhao
    Jun Yang
    Fang Tian
    Xiteng Chen
    Jingli Liang
    Shaochong Bu
    Eye, 2024, 38 : 132 - 137