Ultrathin Strut Biodegradable Polymer-Coated Sirolimus-Eluting Coronary Stents: Patient-Level Pooled Analysis From Two Indian Registries

被引:2
|
作者
Pothineni, Ramesh Babu [1 ]
Ajmera, Prakash [2 ]
Chawla, Kamal Kumar [2 ]
Mantravadi, Sai Sudhakar [3 ,4 ]
Pathak, Abhijit [5 ]
Inamdar, Manohar K. [5 ,6 ]
V. Jariwala, Pankaj
Vijan, Vikrant [7 ]
Vijan, Vinod [7 ]
Potdar, Anil [8 ]
机构
[1] Malla Reddy Narayana Multispecial Hosp, Cardiol, Hyderabad, Pakistan
[2] Gleneagles Global Hosp, Cardiol, Hyderabad, Pakistan
[3] Swasthya Hosp, Cardiol, Ahmednagar, India
[4] Med Res Ctr, Ahmednagar, India
[5] Ashwini Hosp, Cardiol, Solapur, India
[6] MaxCure Hosp, Cardiol, Hyderabad, India
[7] Vijan Cardiac & Crit Care Ctr, Cardiol, Nasik, India
[8] Parisoha Fdn Pvt Ltd, Cardiol, Mumbai, India
关键词
percutaneous coronary intervention; multivessel disease; drug -eluting stents; diabetes; coronary; occlusion; CLINICAL-OUTCOMES; ARTERY-DISEASE; DIABETES-MELLITUS; GENDER-DIFFERENCES; RANDOMIZED-TRIAL; STANDARD STENT; INTERVENTION; EVEROLIMUS; REVASCULARIZATION; IMPACT;
D O I
10.7759/cureus.41743
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background Despite significant evolution in stent technology, female gender, and patients with diabetes mellitus, multivessel disease, total occlusions, long lesions, and small vessels represent the "Achilles' heel" of contemporary percutaneous coronary intervention (PCI). We performed a pooled analysis of high-risk subgroup on patient-level data from the T-Flex registry (1,203 patients) and a real-world Indian registry (1,269 patients), with the aim of assessing one-year safety and clinical performance of ultrathin strut biodegradable polymer-coated Supra family of sirolimus-eluting stents (SES) (Sahajanand Medical Technologies Limited, Surat, India) in the real-world, all-comer population. Method We pooled the following high-risk subgroups data from two all-comer registries: female gender (n=678), diabetes mellitus (n=852), multivessel disease (n=406), total occlusions (n=420), long lesions (>28 mm) (n=1241), and small vessels (& LE;2.5 mm) (n=726). Both the registries included patients with coronary artery disease who underwent implantation of at least one SES belonging to the Supra family of stents from May 2016 until March 2018, irrespective of lesion complexity and comorbidities. The primary endpoint was the incidence of target lesion failure (TLF), a composite of cardiac death, target vessel myocardial infarction, and clinically indicated target lesion revascularization by percutaneous or surgical methods up to one year. The safety endpoint was stent thrombosis. Results According to prespecified high-risk subgroups, one-year rates of TLF and overall stent thrombosis, respectively, were as follows: female gender (4.9% and 0.6%), diabetes mellitus (6.9% and 1.0%), multivessel disease (6.4% and 0.8%), total occlusions (5.2% and 0.5%), long lesions (>28 mm) (6.6% and 0.8%), and small vessels (& LE;2.5 mm) (6.1% and 1.3%). Conclusion This present pooled analysis demonstrated the one-year safety and clinical performance of ultrathin strut biodegradable polymer-coated Supra family of SES in a real-world, all-comer population, with considerably low rates of TLF and stent thrombosis.
引用
收藏
页数:13
相关论文
共 50 条
  • [1] One-Year Outcomes of Biodegradable Polymer-Coated Sirolimus-Eluting Coronary Stent in Acute Coronary Syndrome: A Patient-Level Pooled Analysis from Two Indian Registries
    Pothineni, Ramesh Babu
    Ajmera, Prakash
    Chawla, Kamal Kumar
    Mantravadi, Sai Sudhakar
    Pathak, Abhijit
    Inamdar, Manohar K.
    Jariwala, Pankaj Vinod
    Vijan, Vikrant
    Vijan, Vinod
    Potdar, Anil
    CARDIOLOGY, 2024, 149 (05) : 411 - 419
  • [2] The outcome of ultrathin-strut biodegradable polymer-coated sirolimus-eluting stents in coronary artery disease patients - A feasibility study
    Panduranga, Prashanth
    Mohammed, Azzam
    HEART VIEWS, 2023, 24 (01): : 1 - 5
  • [3] Ultrathin strut biodegradable-polymer sirolimus-eluting stents: being wary or going with the flow?
    Cassese, Salvatore
    Lahmann, Anna Lena
    Joner, Michael
    JOURNAL OF THORACIC DISEASE, 2018, 10 (02) : 688 - 692
  • [4] Preferable vascular healing of ultrathin strut biodegradable-polymer sirolimus-eluting stents in patients with acute coronary syndrome
    Akito Kawamura
    Yasuyuki Egami
    Shodai Kawanami
    Hiroki Sugae
    Kohei Ukita
    Hitoshi Nakamura
    Yutaka Matsuhiro
    Koji Yasumoto
    Masaki Tsuda
    Naotaka Okamoto
    Yasuharu Matsunaga-Lee
    Masamichi Yano
    Masami Nishino
    Jun Tanouchi
    Cardiovascular Intervention and Therapeutics, 2022, 37 : 681 - 690
  • [5] Preferable vascular healing of ultrathin strut biodegradable-polymer sirolimus-eluting stents in patients with acute coronary syndrome
    Kawamura, Akito
    Egami, Yasuyuki
    Kawanami, Shodai
    Sugae, Hiroki
    Ukita, Kohei
    Nakamura, Hitoshi
    Matsuhiro, Yutaka
    Yasumoto, Koji
    Tsuda, Masaki
    Okamoto, Naotaka
    Matsunaga-Lee, Yasuharu
    Yano, Masamichi
    Nishino, Masami
    Tanouchi, Jun
    CARDIOVASCULAR INTERVENTION AND THERAPEUTICS, 2022, 37 (04) : 681 - 690
  • [6] Biodegradable polymer-coated thin strut sirolimus-eluting stent versus durable polymer-coated everolimus-eluting stent in the diabetic population
    Gasior, Pawel
    Gierlotka, Marek
    Szczurek-Katanski, Krzysztof
    Osuch, Marcin
    Roleder, Magda
    Hawranek, Michal
    Wojakowski, Wojciech
    Polonski, Lech
    CARDIOLOGY JOURNAL, 2021, 28 (02) : 235 - 243
  • [7] Real-World Use Of Ultrathin-Strut Biodegradable Polymer-Coated Sirolimus-Eluting Stents In Patients With Coronary Artery Disease: 6-Month Clinical Outcomes
    Ajmera, Prakash
    Pothineni, Ramesh
    Chawla, Kamal Kumar
    Mantravadi, Sai Sudhakar
    Jariwala, Pankaj Vinod
    Vijan, Vinod
    Vijan, Vikrant
    VASCULAR HEALTH AND RISK MANAGEMENT, 2019, 15 : 439 - 447
  • [8] Final five-year outcomes after implantation of biodegradable polymer-coated biolimus-eluting stents versus durable polymer-coated sirolimus-eluting stents
    Jakobsen, Lars
    Christiansen, Evald H.
    Maeng, Michael
    Hansen, Knud N.
    Kristensen, Steen D.
    Botker, Hans E.
    Terkelsen, Christian J.
    Jensen, Svend E.
    Raungaard, Bent
    Madsen, Morten
    Lassen, Jens F.
    Jensen, Lisette O.
    EUROINTERVENTION, 2017, 13 (11) : 1337 - 1345
  • [9] Evaluation of Ultrathin Strut Biodegradable Polymer-Coated Sirolimus-Eluting Stents in an All-Comers Patient Population: 1-Year Results of the S-FLEX Slovakia Registry
    Hudec, Martin
    Kupec, Andrej
    Gazdic, Pavol
    ANATOLIAN JOURNAL OF CARDIOLOGY, 2024, 28 (03): : 142 - 149
  • [10] Clinical Outcomes of Biodegradable Polymer-Coated Ultrathin Strut Sirolimus-Eluting Stents in a Real-World Patient Population With High- Risk Subgroups: Three-Year Results
    Pothineni, Ramesh Babu
    Vijan, Vikrant
    Mantravadi, Sai Sudhakar
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2022, 80 (12) : B67 - B67