Theoretical analysis of the attenuation characteristics of high-frequency pressure vibration in pumped storage power station

被引:6
|
作者
Yang, Xiuwei [1 ,2 ,3 ]
Lian, Jijian [1 ,2 ,3 ]
Zhang, Ziliang [1 ,2 ]
Zeng, Yonghong [1 ,2 ,3 ]
机构
[1] Tianjin Univ, State Key Lab Hydraul Engn Simulat & Safety, Tianjin 300350, Peoples R China
[2] Tianjin Univ, Sch Civil Engn, Tianjin 300350, Peoples R China
[3] Technol Innovat Ctr Hydropower Wind Solar & Energy, Tibet 850000, Peoples R China
关键词
Fluid -filled pipe; Fluid -dominate wave; Coupling model; Attenuation characteristics; High -frequency pressure fluctuation; Pumped storage power station; CIRCULAR LINED TUNNEL; FLUID-STRUCTURE INTERACTION; IMPERFECT INTERFACE; DYNAMIC-RESPONSE; LOAD REJECTION; HYDRO; INCLUSION; BEHAVIOR; SYSTEM; WAVES;
D O I
10.1016/j.est.2023.108341
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
High-frequency vibration is a common hydraulic phenomenon in pumped storage power station. In this study, a theoretical model for analyzing the high-frequency vibration in fluid-pipe-surrounding support coupling system is established. The discontinuity characteristics between the pipe wall and surrounding medium are modeled by the linear spring model, where axial and radial spring constants represent the bounding degree of the pipe and surrounding support. The relation between the wave speed and attenuation characteristics of the high-frequency vibration could be derived from the established theoretical model. And a strategy for estimating the attenuation rate of the high-frequency vibration is proposed. According to the theoretical analysis results, the connection and transition of the vibration energy through the pipe and surrounding support mainly rely on radial bounding. With decreasing in the compressibility of the pipe wall and the surrounding medium, the attenuation rate of high-frequency decreases. One of the reasons why the high-frequency pressure vibration could propagate over long distances in the pumped storage power station may be attributed to the little compressibility of the solid structures in the headrace tunnel.
引用
收藏
页数:11
相关论文
共 50 条
  • [1] Propagation characteristics analysis of high-frequency vibration in pumped storage power station based on a 1D fluid-solid coupling model
    Lian, Jijian
    Yang, Xiuwei
    Wang, Haijun
    JOURNAL OF ENERGY STORAGE, 2023, 68
  • [2] A novel numerical model for evaluating the high-frequency vibration intensity of the headrace tunnel in pumped storage power station
    Yang, Xiuwei
    Lian, Jijian
    Wang, Haijun
    Wang, Xiaoqun
    RENEWABLE ENERGY, 2025, 238
  • [3] Analysis of the high pressure tunnel of the Guangzhou pumped storage power station
    Guangdong Provincial Design Institute of Water Conservancy and Electric Power, Guangzhou, China
    不详
    Proc Inst Civ Eng Water Marit Energ, 1 (25-31):
  • [4] Analysis of the high pressure tunnel of the Guangzhou pumped storage power station
    Lu, ZK
    Wrobel, LC
    PROCEEDINGS OF THE INSTITUTION OF CIVIL ENGINEERS-WATER MARITIME AND ENERGY, 1997, 124 (01): : 25 - 31
  • [5] Modeling and simulation of high-frequency vibration of headrace tunnel in a pumped storage power station considering imperfect bounding condition
    Yang, Xiuwei
    Lian, Jijian
    Wang, Haijun
    Wang, Xiaoqun
    THIN-WALLED STRUCTURES, 2025, 210
  • [6] Multi-frequency oscillation characteristics and stability of the pumped storage power station based on a theoretical analytical method
    Chen, Sheng
    Cao, Xinxin
    Liu, Yi
    Wang, Zhenhui
    Zhang, Jian
    JOURNAL OF ENERGY STORAGE, 2024, 102
  • [8] Research on Vibration Characteristics of an Underground Powerhouse of Large Pumped-Storage Power Station
    Zhang, Lijuan
    Guo, Yaohua
    Wang, Haijun
    Yang, Xuliang
    Lian, Jijian
    ENERGIES, 2022, 15 (24)
  • [9] Analyses of restraint of surrounding rock and structural vibration characteristics of underground powerhouse for pumped storage power station
    Cui Qi
    Hou Jian-guo
    Song Yi-le
    ROCK AND SOIL MECHANICS, 2019, 40 (02) : 809 - 817
  • [10] Environmental Benefit Analysis of Pumped Storage Power Station
    Lu Han
    Chen Chen
    Hong Yongyuan
    Li Wei
    PROCEEDINGS OF THE 2017 2ND INTERNATIONAL CONFERENCE ON CIVIL, TRANSPORTATION AND ENVIRONMENTAL ENGINEERING (ICCTE 2017), 2017, 135 : 524 - 528